Skip to main content
Erschienen in: Clinical Oral Investigations 9/2023

18.07.2023 | Research

The effect of layer thıckness on the accuracy of the dıfferent ın-house clear alıgner attachments

verfasst von: Kübra Gülnur Topsakal, Şule Gökmen, Ebru Yurdakurban, Gökhan Serhat Duran, Serkan Görgülü

Erschienen in: Clinical Oral Investigations | Ausgabe 9/2023

Einloggen, um Zugang zu erhalten

Abstract

Objective

The accuracy of the attachments, one of the key components of clear aligner therapy, is important for obtaining more precise tooth movement. The aim of this study was to evaluate the accuracy of the ovoid, hemi-ellipsoid, and vertical rectangular attachments produced by the digital light-processing(DLP) 3-dimensional printing technologies with 25 µm, 75 µm, and 125 µm layer thickness.

Materials and methods

The ovoid, hemi-ellipsoid, and vertical rectangular attachments were positioned onto the convex surface of the central incisor by the software. The printing process was carried out by a DLP printer using a commercially printed resin with 25 µm, 75 µm, and 125 µm layer thickness (n = 30, for each group). All test models’ digital data was exported into the reverse engineering software for the superimposition. After selecting the 5 comparison points for the ovoid and vertical rectangular attachments, and 6 comparison points for the hemi-ellipsoid attachment, the Root Mean Square (RMS) was evaluated for each group.

Results

There is a statistically significant difference between the 25 µm and 125 µm layer thickness of total RMS values in the ovoid, hemi-ellipsoid, and vertical rectangular attachment groups (p = 0.001, p = 0.03, and p = 0.00 respectively). The printing time with the 25 µm layer thickness was 4 times longer than with the 125 µm layer thickness.

Conclusions

This study revealed that the accuracy of the attachments used for in-house clear aligner therapy is affected by the layer thickness of the 3D printer.

Clinical relevance

The layer thickness of the 3D printer is a crucial factor in determining attachment accuracy, but its clinical significance is minimal. Clinicians should make informed decisions about the appropriate layer thickness, taking into account their workflow preferences, time constraints, and other practical considerations specific to their clinical practice.
Literatur
1.
Zurück zum Zitat Tai S (2018) Clear Aligner Technique. Qunintessence Publishing Co Inc, Hanover Park, IL Tai S (2018) Clear Aligner Technique. Qunintessence Publishing Co Inc, Hanover Park, IL
7.
Zurück zum Zitat Hennessy J, Al-Awadhi EA (2016) Clear aligners generations and orthodontic tooth Hennessy J, Al-Awadhi EA (2016) Clear aligners generations and orthodontic tooth
10.
Zurück zum Zitat Schmidleithner C, Kalaskar DM (2018) Stereolithography, IntechOpen Schmidleithner C, Kalaskar DM (2018) Stereolithography, IntechOpen
13.
Zurück zum Zitat Al-Imam H, Gram M, Benetti AR et al (2018) Accuracy of stereolithography additive casts used in a digital workflow. J Prosthet Dent 119:580–585CrossRefPubMed Al-Imam H, Gram M, Benetti AR et al (2018) Accuracy of stereolithography additive casts used in a digital workflow. J Prosthet Dent 119:580–585CrossRefPubMed
14.
Zurück zum Zitat You S-M, You S-G, Kang S-Y et al (2021) Evaluation of the accuracy (trueness and precision) of a maxillary trial denture according to the layer thickness: An in vitro study. J Prosthet Dent 125:139–145CrossRefPubMed You S-M, You S-G, Kang S-Y et al (2021) Evaluation of the accuracy (trueness and precision) of a maxillary trial denture according to the layer thickness: An in vitro study. J Prosthet Dent 125:139–145CrossRefPubMed
15.
Zurück zum Zitat International Organization for Standardization (1994) ISO 5725–1. Accuracy (trueness and precision) of measurement methods and results - Part 1: General principles and definitions. Geneva: International Organization for Standardization. Available at: https://www.iso.org/obp/ui/#iso:std:iso: 5725:-1:ed-1:v1:en. International Organization for Standardization (1994) ISO 5725–1. Accuracy (trueness and precision) of measurement methods and results - Part 1: General principles and definitions. Geneva: International Organization for Standardization. Available at: https://​www.​iso.​org/​obp/​ui/​#iso:​std:​iso: 5725:-1:ed-1:v1:en.
16.
Zurück zum Zitat Flügge TV, Schlager S, Nelson K et al (2013) Precision of intraoral digital dental impressions with iTero and extraoral digitization with the iTero and a model scanner. Am J Orthod Dentofac Orthop 144:471–478CrossRef Flügge TV, Schlager S, Nelson K et al (2013) Precision of intraoral digital dental impressions with iTero and extraoral digitization with the iTero and a model scanner. Am J Orthod Dentofac Orthop 144:471–478CrossRef
18.
Zurück zum Zitat Cousley RRJ (2020) Introducing 3D printing in your orthodontic practice. J Orthod 47:265–272CrossRefPubMed Cousley RRJ (2020) Introducing 3D printing in your orthodontic practice. J Orthod 47:265–272CrossRefPubMed
19.
Zurück zum Zitat Baek JW, Shin S-Y (2020) Accuracy of dies fabricated by various three dimensional printing systems: a comparative study. J Dent Rehabil Appl Sci 36:242–253CrossRef Baek JW, Shin S-Y (2020) Accuracy of dies fabricated by various three dimensional printing systems: a comparative study. J Dent Rehabil Appl Sci 36:242–253CrossRef
20.
Zurück zum Zitat Felzmann R et al (2012) Lithography-based additive manufacturing of cellular ceramic structures. Adv Eng Mater 14:1052–1058CrossRef Felzmann R et al (2012) Lithography-based additive manufacturing of cellular ceramic structures. Adv Eng Mater 14:1052–1058CrossRef
21.
Zurück zum Zitat Zhang Z, Li P, Chu F et al (2019) Influence of the three-dimensional printing technique and printing layer thickness on model accuracy. J Orofac Orthop der Kieferorthopadie 80:4 Zhang Z, Li P, Chu F et al (2019) Influence of the three-dimensional printing technique and printing layer thickness on model accuracy. J Orofac Orthop der Kieferorthopadie 80:4
22.
Zurück zum Zitat Favero CS, English JD, Cozad BE et al (2017) Effect of print layer height and printer type on the accuracy of 3-dimensional printed orthodontic models. Am J Orthod Dentofac Orthop 152:557–565CrossRef Favero CS, English JD, Cozad BE et al (2017) Effect of print layer height and printer type on the accuracy of 3-dimensional printed orthodontic models. Am J Orthod Dentofac Orthop 152:557–565CrossRef
25.
Zurück zum Zitat Dong T, Wang X, Xia L et al (2020) Accuracy of different tooth surfaces on 3D printed dental models: orthodontic perspective. BMC Oral Health 20:1–8CrossRef Dong T, Wang X, Xia L et al (2020) Accuracy of different tooth surfaces on 3D printed dental models: orthodontic perspective. BMC Oral Health 20:1–8CrossRef
26.
Zurück zum Zitat Lin LH, Granatelli J, Alifui-Segbaya F et al (2021) A proposed ın vitro methodology for assessing the accuracy of three-dimensionally printed dental models and the ımpact of storage on dimensional stability. Appl Sci 11:5994CrossRef Lin LH, Granatelli J, Alifui-Segbaya F et al (2021) A proposed ın vitro methodology for assessing the accuracy of three-dimensionally printed dental models and the ımpact of storage on dimensional stability. Appl Sci 11:5994CrossRef
27.
Zurück zum Zitat Bell A, Ayoub AF, Siebert P (2014) Assessment of the accuracy of a three-dimensional imaging system for archiving dental study model. J Orthod Bell A, Ayoub AF, Siebert P (2014) Assessment of the accuracy of a three-dimensional imaging system for archiving dental study model. J Orthod
28.
Zurück zum Zitat Hazeveld A, Slater JJRH, Ren Y (2014) Accuracy and reproducibility of dental replica models reconstructed by different rapid prototyping techniques. Am J Orthod Dentofac Orthop 145:108–115CrossRef Hazeveld A, Slater JJRH, Ren Y (2014) Accuracy and reproducibility of dental replica models reconstructed by different rapid prototyping techniques. Am J Orthod Dentofac Orthop 145:108–115CrossRef
29.
Zurück zum Zitat Hassan WNW, Yusoff Y, Mardi NA (2017) Comparison of reconstructed rapid prototyping models produced by 3-dimensional printing and conventional stone models with different degrees of crowding. Am J Orthod Dentofac Orthop 151:209–218CrossRef Hassan WNW, Yusoff Y, Mardi NA (2017) Comparison of reconstructed rapid prototyping models produced by 3-dimensional printing and conventional stone models with different degrees of crowding. Am J Orthod Dentofac Orthop 151:209–218CrossRef
30.
Zurück zum Zitat Halazonetis DJ (2001) Acquisition of 3-dimensional shapes from images. Am J Orthod Dentofac Orthop 119:556–560CrossRef Halazonetis DJ (2001) Acquisition of 3-dimensional shapes from images. Am J Orthod Dentofac Orthop 119:556–560CrossRef
Metadaten
Titel
The effect of layer thıckness on the accuracy of the dıfferent ın-house clear alıgner attachments
verfasst von
Kübra Gülnur Topsakal
Şule Gökmen
Ebru Yurdakurban
Gökhan Serhat Duran
Serkan Görgülü
Publikationsdatum
18.07.2023
Verlag
Springer Berlin Heidelberg
Erschienen in
Clinical Oral Investigations / Ausgabe 9/2023
Print ISSN: 1432-6981
Elektronische ISSN: 1436-3771
DOI
https://doi.org/10.1007/s00784-023-05153-5

Weitere Artikel der Ausgabe 9/2023

Clinical Oral Investigations 9/2023 Zur Ausgabe

„Übersichtlicher Wegweiser“: Lauterbachs umstrittener Klinik-Atlas ist online

17.05.2024 Klinik aktuell Nachrichten

Sie sei „ethisch geboten“, meint Gesundheitsminister Karl Lauterbach: mehr Transparenz über die Qualität von Klinikbehandlungen. Um sie abzubilden, lässt er gegen den Widerstand vieler Länder einen virtuellen Klinik-Atlas freischalten.

Klinikreform soll zehntausende Menschenleben retten

15.05.2024 Klinik aktuell Nachrichten

Gesundheitsminister Lauterbach hat die vom Bundeskabinett beschlossene Klinikreform verteidigt. Kritik an den Plänen kommt vom Marburger Bund. Und in den Ländern wird über den Gang zum Vermittlungsausschuss spekuliert.

Darf man die Behandlung eines Neonazis ablehnen?

08.05.2024 Gesellschaft Nachrichten

In einer Leseranfrage in der Zeitschrift Journal of the American Academy of Dermatology möchte ein anonymer Dermatologe bzw. eine anonyme Dermatologin wissen, ob er oder sie einen Patienten behandeln muss, der eine rassistische Tätowierung trägt.

Ein Drittel der jungen Ärztinnen und Ärzte erwägt abzuwandern

07.05.2024 Klinik aktuell Nachrichten

Extreme Arbeitsverdichtung und kaum Supervision: Dr. Andrea Martini, Sprecherin des Bündnisses Junge Ärztinnen und Ärzte (BJÄ) über den Frust des ärztlichen Nachwuchses und die Vorteile des Rucksack-Modells.

Update Zahnmedizin

Bestellen Sie unseren kostenlosen Newsletter und bleiben Sie gut informiert – ganz bequem per eMail.