Excerpt

We read with great attention the article by Nien-Hsun Wu et al. about comparing the pulmonary artery catheter (PAC) and the IV generation of the FloTrac system (Edwards Lifesciences, Irvine, USA) [1]. …
Literatur
1.
Zurück zum Zitat Wu NH, Hsieh TH, Chang CY, Shih PC, Kao MC, Lin HY (2023) Validation of cardiac output estimation using the fourth-generation FloTrac/EV1000™ system in patients undergoing robotic-assisted off-pump coronary artery bypass surgery. Heart Vessels 38(3):341–347CrossRefPubMed Wu NH, Hsieh TH, Chang CY, Shih PC, Kao MC, Lin HY (2023) Validation of cardiac output estimation using the fourth-generation FloTrac/EV1000™ system in patients undergoing robotic-assisted off-pump coronary artery bypass surgery. Heart Vessels 38(3):341–347CrossRefPubMed
2.
Zurück zum Zitat Vetrugno L, Costa MG, Spagnesi L, Pompei L, Chiarandini P, Gimigliano I, Della Rocca G (2011) Uncalibrated arterial pulse cardiac output measurements in patients with moderately abnormal left ventricular function. J Cardiothorac Vasc Anesth 25(1):53–58CrossRefPubMed Vetrugno L, Costa MG, Spagnesi L, Pompei L, Chiarandini P, Gimigliano I, Della Rocca G (2011) Uncalibrated arterial pulse cardiac output measurements in patients with moderately abnormal left ventricular function. J Cardiothorac Vasc Anesth 25(1):53–58CrossRefPubMed
3.
Zurück zum Zitat Bajorat J, Hofmockel R, Vagts DA, Janda M, Pohl B, Beck C, Noeldge-Schomburg G (2006) Comparison of invasive and less-invasive techniques of cardiac output measurement under different haemodynamic conditions in a pig model. Eur J Anaesthesiol 23(1):23–30CrossRefPubMed Bajorat J, Hofmockel R, Vagts DA, Janda M, Pohl B, Beck C, Noeldge-Schomburg G (2006) Comparison of invasive and less-invasive techniques of cardiac output measurement under different haemodynamic conditions in a pig model. Eur J Anaesthesiol 23(1):23–30CrossRefPubMed
5.
Zurück zum Zitat Critchley LA, Critchley JA (1999) A meta-analysis of studies using bias and precision statistics to compare cardiac output measurement techniques. J Clin Monit Comput 15(2):85–91CrossRefPubMed Critchley LA, Critchley JA (1999) A meta-analysis of studies using bias and precision statistics to compare cardiac output measurement techniques. J Clin Monit Comput 15(2):85–91CrossRefPubMed
6.
Zurück zum Zitat Peyton PJ, Chong SW (2010) Minimally invasive measurement of cardiac output during surgery and critical care: a meta-analysis of accuracy and precision. Anesthesiology 113(5):1220–1235CrossRefPubMed Peyton PJ, Chong SW (2010) Minimally invasive measurement of cardiac output during surgery and critical care: a meta-analysis of accuracy and precision. Anesthesiology 113(5):1220–1235CrossRefPubMed
7.
Zurück zum Zitat Costa MG, Chiarandini P, Scudeller L, Vetrugno L, Pompei L, Serena G, Buttera S, Della Rocca G (2014) Uncalibrated continuous cardiac output measurement in liver transplant patients: LiDCOrapid™ system versus pulmonary artery catheter. J Cardiothorac Vasc Anesth 28(3):540–546CrossRefPubMed Costa MG, Chiarandini P, Scudeller L, Vetrugno L, Pompei L, Serena G, Buttera S, Della Rocca G (2014) Uncalibrated continuous cardiac output measurement in liver transplant patients: LiDCOrapid™ system versus pulmonary artery catheter. J Cardiothorac Vasc Anesth 28(3):540–546CrossRefPubMed
Metadaten
Titel
Can arterial shape change with IABP play a role in comparing FlowTrac/EV 1000 vs. pulmonary cardiac output?
verfasst von
Luigi Vetrugno
Cristian Deana
Federico Barbariol
Publikationsdatum
12.12.2023
Verlag
Springer Japan
Erschienen in
Heart and Vessels / Ausgabe 3/2024
Print ISSN: 0910-8327
Elektronische ISSN: 1615-2573
DOI
https://doi.org/10.1007/s00380-023-02346-6

Weitere Artikel der Ausgabe 3/2024

Heart and Vessels 3/2024 Zur Ausgabe

„Jeder Fall von plötzlichem Tod muss obduziert werden!“

17.05.2024 Plötzlicher Herztod Nachrichten

Ein signifikanter Anteil der Fälle von plötzlichem Herztod ist genetisch bedingt. Um ihre Verwandten vor diesem Schicksal zu bewahren, sollten jüngere Personen, die plötzlich unerwartet versterben, ausnahmslos einer Autopsie unterzogen werden.

Hirnblutung unter DOAK und VKA ähnlich bedrohlich

17.05.2024 Direkte orale Antikoagulanzien Nachrichten

Kommt es zu einer nichttraumatischen Hirnblutung, spielt es keine große Rolle, ob die Betroffenen zuvor direkt wirksame orale Antikoagulanzien oder Marcumar bekommen haben: Die Prognose ist ähnlich schlecht.

Neuer Myosin-Inhibitor bei hypertropher Kardiomyopathie von Nutzen

17.05.2024 Kardiomyopathie Nachrichten

Mit Aficamten hat ein zweiter kardialer Myosin-Inhibitor seinen therapeutischen Nutzen bei symptomatischen Patienten mit obstruktiver hypertropher Kardiomyopathie (HCM) in einer randomisierten Phase-III-Studie klar unter Beweis gestellt.

Schlechtere Vorhofflimmern-Prognose bei kleinem linken Ventrikel

17.05.2024 Vorhofflimmern Nachrichten

Nicht nur ein vergrößerter, sondern auch ein kleiner linker Ventrikel ist bei Vorhofflimmern mit einer erhöhten Komplikationsrate assoziiert. Der Zusammenhang besteht nach Daten aus China unabhängig von anderen Risikofaktoren.

Update Kardiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.