Skip to main content

03.05.2024 | ORIGINAL RESEARCH

Impact of inter-lesion distance and first-pass isolation on outcomes of pulmonary venous isolation for paroxysmal atrial fibrillation

verfasst von: Dan Bo, Dongsheng Zhao, Yan Dong, Wei Zhao, Qiushi Chen, Nishant Yadav, Pipin Kojodjojo, Fengxiang Zhang

Erschienen in: Journal of Interventional Cardiac Electrophysiology

Einloggen, um Zugang zu erhalten

Abstract

Background

Contiguity of ablation lesions is a critical determinant of success for paroxysmal atrial fibrillation (PAF) ablation. Evidence supports maintaining an inter-lesional distance (ILD) ≤ 6 mm during pulmonary venous isolation (PVI). Meanwhile, first-pass isolation (FPI) on PVI outcome in follow-up was not deeply studied. The impact of ILD and FPI on PAF ablation outcomes was investigated.

Methods

Consecutive PAF patients who underwent first-time antral PVI were recruited. Coordinates of ablation points were extracted from the electro-anatomical mapping system and analyzed using custom-developed software to determine the ILD. A gap is defined as ILD greater than 6 mm. FPI was defined as the achievement of PVI by encircling the ipsilateral veins while simultaneously recording their electrical activity using a multipolar catheter. The primary endpoint was freedom from documented atrial arrhythmias including AF, atrial tachycardia (AT), or atrial flutter (AFL) lasting longer than 30 s during follow-up.

Results

A total of 105 patients underwent first-time antral PVI. During 13.3 ± 0.6 months of follow-up, atrial arrhythmias recurrence was noted in 22.9% of the patients. Atrial arrhythmia recurrence was significantly higher in patients with more gaps (> 2) (37.0% versus 11.9%, P < 0.01), and the number of gaps was an independent predictor of AF/AT/AFL recurrence. (Hazard ratio [HR] 1.20, 95% CI 1.03–1.40, P = 0.02). The group with FPI for at least one ipsilateral pair of PVs exhibited a decreased number of gaps (2.0 versus 7.0, P < 0.01) and demonstrated a significant correlation with a reduction of recurrence (HR 0.26, 95% CI 0.09–0.71, P = 0.01). Among 16 patients who underwent repeat ablation, the number of gaps during the index PVI was associated with PV reconnection (PVR) (P < 0.01).

Conclusions

Gaps created during PVI are a modifiable determinant of AF/AT/AFL recurrence, and avoidance of gaps is crucial to improve clinical outcomes of PAF ablation. In addition, FPI exhibited a strong predictive capability for clinical success in patients with PAF.

Graphical Abstract

Anhänge
Nur mit Berechtigung zugänglich
Literatur
1.
Zurück zum Zitat Parameswaran R, Al-Kaisey AM, Kalman JM. Catheter ablation for atrial fibrillation: current indications and evolving technologies. Nat Rev Cardiol. 2021;18(3):210–25.CrossRefPubMed Parameswaran R, Al-Kaisey AM, Kalman JM. Catheter ablation for atrial fibrillation: current indications and evolving technologies. Nat Rev Cardiol. 2021;18(3):210–25.CrossRefPubMed
2.
Zurück zum Zitat Kuck KH, Hoffmann BA, Ernst S, et al. Impact of complete versus incomplete circumferential lines around the pulmonary veins during catheter ablation of paroxysmal atrial fibrillation: results from the gap-atrial fibrillation-German atrial fibrillation competence network 1 trial. Circ Arrhythm Electrophysiol. 2016;9(1):e003337.CrossRefPubMed Kuck KH, Hoffmann BA, Ernst S, et al. Impact of complete versus incomplete circumferential lines around the pulmonary veins during catheter ablation of paroxysmal atrial fibrillation: results from the gap-atrial fibrillation-German atrial fibrillation competence network 1 trial. Circ Arrhythm Electrophysiol. 2016;9(1):e003337.CrossRefPubMed
3.
Zurück zum Zitat Solimene F, Schillaci V, Shopova G, et al. Safety and efficacy of atrial fibrillation ablation guided by ablation index module. J Interv Card Electrophysiol. 2019;54(1):9–15.CrossRefPubMed Solimene F, Schillaci V, Shopova G, et al. Safety and efficacy of atrial fibrillation ablation guided by ablation index module. J Interv Card Electrophysiol. 2019;54(1):9–15.CrossRefPubMed
4.
Zurück zum Zitat Inoue K, Tanaka N, Ikada Y, et al. Characterizing clinical outcomes and factors associated with conduction gaps in VISITAG SURPOINT-guided catheter ablation for atrial fibrillation. J Arrhythm. 2021;37(3):574–83.CrossRefPubMedPubMedCentral Inoue K, Tanaka N, Ikada Y, et al. Characterizing clinical outcomes and factors associated with conduction gaps in VISITAG SURPOINT-guided catheter ablation for atrial fibrillation. J Arrhythm. 2021;37(3):574–83.CrossRefPubMedPubMedCentral
5.
Zurück zum Zitat Phlips T, Taghji P, El Haddad M, et al. Improving procedural and one-year outcome after contact force-guided pulmonary vein isolation: the role of interlesion distance, ablation index, and contact force variability in the ‘CLOSE’-protocol. Europace. 2018;20(FI_3):f419–27.CrossRefPubMed Phlips T, Taghji P, El Haddad M, et al. Improving procedural and one-year outcome after contact force-guided pulmonary vein isolation: the role of interlesion distance, ablation index, and contact force variability in the ‘CLOSE’-protocol. Europace. 2018;20(FI_3):f419–27.CrossRefPubMed
6.
Zurück zum Zitat Taghji P, El Haddad M, Phlips T, et al. Evaluation of a strategy aiming to enclose the pulmonary veins with contiguous and optimized radiofrequency lesions in paroxysmal atrial fibrillation: a pilot study. JACC Clin Electrophysiol. 2018;4(1):99–108.CrossRefPubMed Taghji P, El Haddad M, Phlips T, et al. Evaluation of a strategy aiming to enclose the pulmonary veins with contiguous and optimized radiofrequency lesions in paroxysmal atrial fibrillation: a pilot study. JACC Clin Electrophysiol. 2018;4(1):99–108.CrossRefPubMed
7.
Zurück zum Zitat Duytschaever M, Vijgen J, De Potter T, et al. Standardized pulmonary vein isolation workflow to enclose veins with contiguous lesions: the multicentre VISTAX trial. Europace. 2020;22(11):1645–52.CrossRefPubMed Duytschaever M, Vijgen J, De Potter T, et al. Standardized pulmonary vein isolation workflow to enclose veins with contiguous lesions: the multicentre VISTAX trial. Europace. 2020;22(11):1645–52.CrossRefPubMed
8.
Zurück zum Zitat Yazaki K, Ejima K, Kataoka S, et al. Regional differences in the predictors of acute electrical reconnection following high-power pulmonary vein isolation for paroxysmal atrial fibrillation. J Arrhythm. 2021;37(5):1260–9.CrossRefPubMedPubMedCentral Yazaki K, Ejima K, Kataoka S, et al. Regional differences in the predictors of acute electrical reconnection following high-power pulmonary vein isolation for paroxysmal atrial fibrillation. J Arrhythm. 2021;37(5):1260–9.CrossRefPubMedPubMedCentral
9.
Zurück zum Zitat Mujovic NM, Marinkovic MM, Markovic N, et al. Risk factors for late reconnections after circumferential pulmonary vein isolation guided by lesion size index - data from repeat invasive electrophysiology procedure. Front Cardiovasc Med. 2022;9:986207.CrossRefPubMed Mujovic NM, Marinkovic MM, Markovic N, et al. Risk factors for late reconnections after circumferential pulmonary vein isolation guided by lesion size index - data from repeat invasive electrophysiology procedure. Front Cardiovasc Med. 2022;9:986207.CrossRefPubMed
10.
Zurück zum Zitat Cappato R, Negroni S, Pecora D, et al. Prospective assessment of late conduction recurrence across radiofrequency lesions producing electrical disconnection at the pulmonary vein ostium in patients with atrial fibrillation. Circulation. 2003;108(13):1599–604.CrossRefPubMed Cappato R, Negroni S, Pecora D, et al. Prospective assessment of late conduction recurrence across radiofrequency lesions producing electrical disconnection at the pulmonary vein ostium in patients with atrial fibrillation. Circulation. 2003;108(13):1599–604.CrossRefPubMed
11.
Zurück zum Zitat Ouyang F, Tilz R, Chun J, et al. Long-term results of catheter ablation in paroxysmal atrial fibrillation: lessons from a 5-year follow-up. Circulation. 2010;122(23):2368–77.CrossRefPubMed Ouyang F, Tilz R, Chun J, et al. Long-term results of catheter ablation in paroxysmal atrial fibrillation: lessons from a 5-year follow-up. Circulation. 2010;122(23):2368–77.CrossRefPubMed
12.
Zurück zum Zitat Ninomiya Y, Inoue K, Tanaka N, et al. Absence of first-pass isolation is associated with poor pulmonary vein isolation durability and atrial fibrillation ablation outcomes. J Arrhythm. 2021;37(6):1468–76.CrossRefPubMedPubMedCentral Ninomiya Y, Inoue K, Tanaka N, et al. Absence of first-pass isolation is associated with poor pulmonary vein isolation durability and atrial fibrillation ablation outcomes. J Arrhythm. 2021;37(6):1468–76.CrossRefPubMedPubMedCentral
13.
Zurück zum Zitat Osorio J, Hunter TD, Rajendra A, Zei P, Silverstein J, Morales G. Predictors of clinical success after paroxysmal atrial fibrillation catheter ablation. J Cardiovasc Electrophysiol. 2021;32(7):1814–21.CrossRefPubMed Osorio J, Hunter TD, Rajendra A, Zei P, Silverstein J, Morales G. Predictors of clinical success after paroxysmal atrial fibrillation catheter ablation. J Cardiovasc Electrophysiol. 2021;32(7):1814–21.CrossRefPubMed
14.
Zurück zum Zitat Mujovic N, Marinkovic M, Lenarczyk R, Tilz R, Potpara TS. Catheter ablation of atrial fibrillation: an overview for clinicians. Adv Ther. 2017;34(8):1897–917.CrossRefPubMedPubMedCentral Mujovic N, Marinkovic M, Lenarczyk R, Tilz R, Potpara TS. Catheter ablation of atrial fibrillation: an overview for clinicians. Adv Ther. 2017;34(8):1897–917.CrossRefPubMedPubMedCentral
15.
Zurück zum Zitat Mujovic NM, Marinkovic MM, Potpara TS, Geller L. Catheter ablation of lone atrial fibrillation. Curr Pharm Des. 2015;21(5):591–612.CrossRefPubMed Mujovic NM, Marinkovic MM, Potpara TS, Geller L. Catheter ablation of lone atrial fibrillation. Curr Pharm Des. 2015;21(5):591–612.CrossRefPubMed
16.
Zurück zum Zitat Nanthakumar K, Plumb VJ, Epstein AE, Veenhuyzen GD, Link D, Kay GN. Resumption of electrical conduction in previously isolated pulmonary veins: rationale for a different strategy? Circulation. 2004;109(10):1226–9.CrossRefPubMed Nanthakumar K, Plumb VJ, Epstein AE, Veenhuyzen GD, Link D, Kay GN. Resumption of electrical conduction in previously isolated pulmonary veins: rationale for a different strategy? Circulation. 2004;109(10):1226–9.CrossRefPubMed
17.
Zurück zum Zitat Erhard N, Mauer T, Ouyang F, et al. Mechanisms of late arrhythmia recurrence after initially successful pulmonary vein isolation in patients with atrial fibrillation. Pacing Clin Electrophysiol. 2023;46(2):161–8.CrossRefPubMed Erhard N, Mauer T, Ouyang F, et al. Mechanisms of late arrhythmia recurrence after initially successful pulmonary vein isolation in patients with atrial fibrillation. Pacing Clin Electrophysiol. 2023;46(2):161–8.CrossRefPubMed
18.
Zurück zum Zitat Ren JF, Callans DJ, Schwartzman D, Michele JJ, Marchlinski FE. Changes in local wall thickness correlate with pathologic lesion size following radiofrequency catheter ablation: an intracardiac echocardiographic imaging study. Echocardiography. 2001;18(6):503–7.CrossRefPubMed Ren JF, Callans DJ, Schwartzman D, Michele JJ, Marchlinski FE. Changes in local wall thickness correlate with pathologic lesion size following radiofrequency catheter ablation: an intracardiac echocardiographic imaging study. Echocardiography. 2001;18(6):503–7.CrossRefPubMed
19.
Zurück zum Zitat Hoffmann P, Diaz Ramirez I, Baldenhofer G, Stangl K, Mont L, Althoff TF. Randomized study defining the optimum target interlesion distance in ablation index-guided atrial fibrillation ablation. Europace. 2020;22(10):1480–6.CrossRefPubMed Hoffmann P, Diaz Ramirez I, Baldenhofer G, Stangl K, Mont L, Althoff TF. Randomized study defining the optimum target interlesion distance in ablation index-guided atrial fibrillation ablation. Europace. 2020;22(10):1480–6.CrossRefPubMed
20.
Zurück zum Zitat Duytschaever M, De Pooter J, Demolder A, et al. Long-term impact of catheter ablation on arrhythmia burden in low-risk patients with paroxysmal atrial fibrillation: the CLOSE to CURE study. Heart Rhythm. 2020;17(4):535–43.CrossRefPubMed Duytschaever M, De Pooter J, Demolder A, et al. Long-term impact of catheter ablation on arrhythmia burden in low-risk patients with paroxysmal atrial fibrillation: the CLOSE to CURE study. Heart Rhythm. 2020;17(4):535–43.CrossRefPubMed
21.
Zurück zum Zitat De Pooter J, Strisciuglio T, El Haddad M, et al. Pulmonary vein reconnection no longer occurs in the majority of patients after a single pulmonary vein isolation procedure. JACC Clin Electrophysiol. 2019;5(3):295–305.CrossRefPubMed De Pooter J, Strisciuglio T, El Haddad M, et al. Pulmonary vein reconnection no longer occurs in the majority of patients after a single pulmonary vein isolation procedure. JACC Clin Electrophysiol. 2019;5(3):295–305.CrossRefPubMed
22.
Zurück zum Zitat Berte B, Hilfiker G, Moccetti F, et al. Pulmonary vein isolation using ablation index vs. CLOSE protocol with a surround flow ablation catheter. EP Europace. 2020;22(1):84–9.CrossRef Berte B, Hilfiker G, Moccetti F, et al. Pulmonary vein isolation using ablation index vs. CLOSE protocol with a surround flow ablation catheter. EP Europace. 2020;22(1):84–9.CrossRef
23.
Zurück zum Zitat Gupta D, Duytschaever M, Berte B, De Potter T. Interlesion distance for radiofrequency pulmonary vein isolation: the quandary between targets and limits. Europace. 2021;23(5):815.CrossRefPubMed Gupta D, Duytschaever M, Berte B, De Potter T. Interlesion distance for radiofrequency pulmonary vein isolation: the quandary between targets and limits. Europace. 2021;23(5):815.CrossRefPubMed
24.
Zurück zum Zitat Yamashita K, Kwan E, Kamali R, et al. Blanking period after radiofrequency ablation for atrial fibrillation guided by ablation lesion maturation based on serial MR imaging. J Cardiovasc Electrophysiol. 2020;31(2):450–6.CrossRefPubMed Yamashita K, Kwan E, Kamali R, et al. Blanking period after radiofrequency ablation for atrial fibrillation guided by ablation lesion maturation based on serial MR imaging. J Cardiovasc Electrophysiol. 2020;31(2):450–6.CrossRefPubMed
25.
Zurück zum Zitat Parmar BR, Jarrett TR, Kholmovski EG, et al. Poor scar formation after ablation is associated with atrial fibrillation recurrence. J Interv Card Electrophysiol. 2015;44(3):247–56.CrossRefPubMedPubMedCentral Parmar BR, Jarrett TR, Kholmovski EG, et al. Poor scar formation after ablation is associated with atrial fibrillation recurrence. J Interv Card Electrophysiol. 2015;44(3):247–56.CrossRefPubMedPubMedCentral
26.
Zurück zum Zitat El Haddad M, Taghji P, Phlips T, et al. Determinants of acute and late pulmonary vein reconnection in contact force-guided pulmonary vein isolation: identifying the weakest link in the ablation chain. Circ Arrhythm Electrophysiol. 2017;10(4):e004867.CrossRefPubMed El Haddad M, Taghji P, Phlips T, et al. Determinants of acute and late pulmonary vein reconnection in contact force-guided pulmonary vein isolation: identifying the weakest link in the ablation chain. Circ Arrhythm Electrophysiol. 2017;10(4):e004867.CrossRefPubMed
27.
Zurück zum Zitat Kiedrowicz RM, Wielusinski M, Krasnik W, et al. The impact of regional maximum tolerated interlesion distance on the long-term ablation outcomes in ablation index guided pulmonary vein isolation for atrial fibrillation. J Clin Med. 2023;12(15):5056.CrossRefPubMedPubMedCentral Kiedrowicz RM, Wielusinski M, Krasnik W, et al. The impact of regional maximum tolerated interlesion distance on the long-term ablation outcomes in ablation index guided pulmonary vein isolation for atrial fibrillation. J Clin Med. 2023;12(15):5056.CrossRefPubMedPubMedCentral
28.
Zurück zum Zitat Lee SH, Tai CT, Hsieh MH, et al. Predictors of non-pulmonary vein ectopic beats initiating paroxysmal atrial fibrillation: implication for catheter ablation. J Am Coll Cardiol. 2005;46(6):1054–9.CrossRefPubMed Lee SH, Tai CT, Hsieh MH, et al. Predictors of non-pulmonary vein ectopic beats initiating paroxysmal atrial fibrillation: implication for catheter ablation. J Am Coll Cardiol. 2005;46(6):1054–9.CrossRefPubMed
29.
Zurück zum Zitat Nery PB, Belliveau D, Nair GM, et al. Relationship between pulmonary vein reconnection and atrial fibrillation recurrence: a systematic review and meta-analysis. JACC Clin Electrophysiol. 2016;2(4):474–83.CrossRefPubMed Nery PB, Belliveau D, Nair GM, et al. Relationship between pulmonary vein reconnection and atrial fibrillation recurrence: a systematic review and meta-analysis. JACC Clin Electrophysiol. 2016;2(4):474–83.CrossRefPubMed
Metadaten
Titel
Impact of inter-lesion distance and first-pass isolation on outcomes of pulmonary venous isolation for paroxysmal atrial fibrillation
verfasst von
Dan Bo
Dongsheng Zhao
Yan Dong
Wei Zhao
Qiushi Chen
Nishant Yadav
Pipin Kojodjojo
Fengxiang Zhang
Publikationsdatum
03.05.2024
Verlag
Springer US
Erschienen in
Journal of Interventional Cardiac Electrophysiology
Print ISSN: 1383-875X
Elektronische ISSN: 1572-8595
DOI
https://doi.org/10.1007/s10840-024-01810-1

„Jeder Fall von plötzlichem Tod muss obduziert werden!“

17.05.2024 Plötzlicher Herztod Nachrichten

Ein signifikanter Anteil der Fälle von plötzlichem Herztod ist genetisch bedingt. Um ihre Verwandten vor diesem Schicksal zu bewahren, sollten jüngere Personen, die plötzlich unerwartet versterben, ausnahmslos einer Autopsie unterzogen werden.

Hirnblutung unter DOAK und VKA ähnlich bedrohlich

17.05.2024 Direkte orale Antikoagulanzien Nachrichten

Kommt es zu einer nichttraumatischen Hirnblutung, spielt es keine große Rolle, ob die Betroffenen zuvor direkt wirksame orale Antikoagulanzien oder Marcumar bekommen haben: Die Prognose ist ähnlich schlecht.

Schlechtere Vorhofflimmern-Prognose bei kleinem linken Ventrikel

17.05.2024 Vorhofflimmern Nachrichten

Nicht nur ein vergrößerter, sondern auch ein kleiner linker Ventrikel ist bei Vorhofflimmern mit einer erhöhten Komplikationsrate assoziiert. Der Zusammenhang besteht nach Daten aus China unabhängig von anderen Risikofaktoren.

Semaglutid bei Herzinsuffizienz: Wie erklärt sich die Wirksamkeit?

17.05.2024 Herzinsuffizienz Nachrichten

Bei adipösen Patienten mit Herzinsuffizienz des HFpEF-Phänotyps ist Semaglutid von symptomatischem Nutzen. Resultiert dieser Benefit allein aus der Gewichtsreduktion oder auch aus spezifischen Effekten auf die Herzinsuffizienz-Pathogenese? Eine neue Analyse gibt Aufschluss.

Update Kardiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.