Abstract

Purpose

The growing incidence of implant-associated infections (IAIs) caused by biofilm-forming Staphylococcus aureus in combination with an increasing resistance to antibiotics requires new therapeutic strategies. Lysostaphin has been shown to eliminate this biofilm. Own studies confirm the effectiveness in a murine model. The current study characterizes the effects of lysostaphin-coated plates in an IAI minipig model.

Methods

The femur of 30 minipigs was stabilized with a five-hole plate, a bone defect was created, and in 20 cases methicillin-resistant Staphylococcus aureus was applied. Ten animals served as control group. After 14 days, local debridement, lavage, and plate exchange (seven-hole plate) were performed. Ten of the infected minipigs received an uncoated plate and 10 a lysostaphin-coated plate. On day 84, the minipigs were again lavaged, followed by euthanasia. Bacterial load was quantified by colony-forming units (CFU). Immunological response was determined by neutrophils, as well as interleukins. Fracture healing was assessed radiologically.

Results

CFU showed significant difference between infected minipigs with an uncoated plate and minipigs with a lysostaphin-coated plate (p = 0.0411). The infection-related excessive callus formation and calcification was significantly greater in the infected animals with an uncoated plate than in animals with a lysostaphin-coated plate (p = 0.0164/p = 0.0033). The analysis of polymorphonuclear neutrophils and interleukins did not reveal any pioneering findings.

Conclusion

This study confirms the minipig model for examining IAI. Furthermore, coating of plates using lysostaphin could be a promising tool in the therapeutic strategies of IAI. Future studies should focus on coating technology of implants and on translation into a clinical model.
Hinweise

Supplementary Information

The online version contains supplementary material available at https://​doi.​org/​10.​1007/​s00068-024-02448-4.
Carina Jaekel and Ceylan D. Windolf contributed equally to this work.

Introduction

The increasing number of fracture-related infection (FRI) is a major complication and challenging problem in trauma surgery. Especially the use of implants enhances the risk of infection, which is the main reason for treatment failure [1]. Implant-associated infection (IAI) in combination with growing resistance to conventional antibiotics requires novel therapeutic strategies. Staphylococci, with the leading species Staphylococcus aureus (SA) and Staphylococcus epidermidis (SE), are the most common causes of FRI, accounting for 30–60% of human cases [24]. SA’s ability to form a biofilm complicates the treatment. This biofilm can be defined as a structured microbial community of cells attached to a substrate and embedded in a matrix of extracellular polymeric substances that they previously produced [5, 6]. It protects bacteria from the penetration of immune cells, and prevents phagocytosis and reactive oxygen species (ROS) killing [610]. Experimental studies as well as clinical practice indicated clearly that in most cases, antibiotic therapy alone is not sufficient to eliminate the biofilm and that bacterial implants usually require surgical therapy [11]. Despite everything, it must be mentioned that each surgery to replace failed implants has a higher risk of recurrence, up to 30%, than that of the initial surgery [12]. Therapeutic strategies to eradicate the biofilm have made great research progress, such as studies on the surface modification of implants. However, these new treatments require further preclinical and clinical validation before they are widely accepted for therapeutic use [13]. Antimicrobial biomaterials currently represent one of the most promising therapeutic strategies [14, 15]. Therefore, the perfect implant surface would be one that reduces bacterial adhesion, confers effective sterilization, and does not compromise bone healing [16]. Great efforts have been made for coated implants, especially titanium plates, with antimicrobial agents to prevent IAIs [17, 18]. In 2014, our working group was able to show that an implant coating with lysostaphin prevents methicillin-sensible Staphylococcus aureus (MSSA) osteomyelitis in a murine model [19]. Lysostaphin is a 27-kDa extracellular antimicrobial endopeptidase produced by Staphylococcus simulans biovar staphylolyticus and was first discovered in the 1960s [20]. Lysostaphin destroys sessile bacteria in a biofilm and can also damage the extracellular biofilm matrix [21]. Moreover, the antibacterial potency of lysostaphin is well documented in animals and humans [20]. With regard to bony infection, the efficacy of lysostaphin has been tested under in vitro and in vivo animal models for the treatment of orthopedic infections [19, 22, 23]. Nonetheless, these studies were all carried out in mice. Examinations in large animal models (e.g., pig or sheep) are pending but are urgently needed to approach the clinical practice and pave the way for future human clinical trials. The most recent study of our working group shows the successful establishment of an IAI by methicillin-resistant Staphylococcus aureus (MRSA) in minipigs [24]. This was deliberately developed as a fundamental for investigating further therapeutic strategies in IAIs.
The aim of this study was to evaluate the effects of lysostaphin-coated plates in a standardized IAI minipig model.

Materials and methods

Animals and ethics statement

In this study, 30 2-year-old Aachener minipigs of heterogeneous sex (eight male, 22 female) with a mean weight of 64 kg were examined (animal facility of the Heinrich Heine University Düsseldorf; Zentrale Einrichtung für Tierforschung und wissenschaftliche Tierschutzaufgaben (ZETT), Germany). All animals were allowed to acclimate for 7 days after arrival before being included in the experiment. The animals were fed with commercial pig food, had free access to water, and were kept in separate stalls with a 12-h light/dark cycle. All animal procedures were carried out under local and national ethical guidelines and were approved by the regional ethical committee, Regional Office for Nature, Environment and Consumer Protection Nordrhein-Westfalen, Germany, with the ethical approval ID 84–02.04.2017.A181.

Bacterial inoculum

The biofilm-forming MRSA strain ATCC 33592 was cultured in BactoTryptic Soy Broth overnight and then diluted 1:10. The mean inoculation colony-forming units (CFU) was 105.

Titanium plate coating

Titanium locking compression plates (LCP, DePuy Synthes, Raynham, USA) were coated with 1 mg/ml lysostaphin (ProSpec, East Brunswick, NJ, USA) in a poly(D,L)-lactide (PDLLA) matrix. PDLLA was dissolved in ethyl acetate (133 mg/ml) and mixed with lysostaphin to obtain a final concentration of 1 mg/ml. Sterile seven-hole LCPs (DePuy Synthes, Raynham, USA) were dipped in PDLLA-lysostaphin mixture and air-dried. This dip-drying step was repeated four times to obtain a multi-layer comprising PDLLA and lysostaphin. Titanium plates were used in animal experiments within 5 days.

Low-grade acute osteitis model

All surgeries were performed under aseptic conditions in the operating rooms of our local animal facility according to the standardized infection model previously established by our research group [24]. For premedication, we used ketamine 10 mg/kg i.m., azaperone 5 mg/kg i.m., diazepam 10–20 mg i.m., and atropine 0.5 mg i.m. The anesthesia was performed via thiopental 5 mg/kg i.v. and 2% isoflurane/oxygen mixture for the induction of anesthesia. The anesthesia was maintained with 1.3% isoflurane/oxygen mixture. Buprenorphine 0.3 mg i.v. was used as an analgesic. The dirt from the skin of the left hind leg was first removed with water and soap, and subsequently disinfected by swabbing with 70% alcohol. Before skin incision, we finally disinfected with Betaisodona. After skin incision in sterile, the fascia of the thigh muscle was exposed and then opened to dissect directly onto the bone. A standardized bone defect of 2.8 × 5 mm was created midway on the left femur using an LCP drill (DePuy Synthes, Raynham, USA). A five-hole LCP titanium plate 3.5 mm (DePuy Synthes, Raynham, USA) was modeled onto the bone. The plate was then implanted laterally on the femur with four locking self-tapping screws (Stardrive®, 3.5 mm, titanium, DePuy Synthes Raynham, USA). In 20 animals, 5 × 5 µl MRSA (ATCC 33592) with a mean CFU of 105 was placed on the plate to dry. Ten animals were given a sterile LCP titanium plate (control group). For postoperative pain management, all animals received oral metamizole 20 mg/kg three times daily for 3 days and buprenorphine 0.3 mg i.m. for the night. They also received oral meloxicam 0.4 mg/kg once daily for 5 days. Systemic antibiotic therapy with enrofloxacin 2.5 mg/kg was performed from the first to the third postoperative day. On day 14, plate change from five-hole to seven-hole LCP titanium plate 3.5 mm (DePuy Synthes Raynham, USA) was performed. The five-hole LCP titanium plate was removed, and lavage and debridement were conducted. Lavage and blood samples were taken. Ten of the infected animals and the 10 control animals received a sterile seven-hole LCP titanium plate. The other 10 infected animals received a seven-hole LCP titanium plate coated with lysostaphin. On day 84, the animals were anesthetized again. Lavage and blood samples were collected, after which the animals were euthanized with an overdose of thiopental. Figure 1 shows the experimental setup.
On day 0, all minipigs received a standardized bone defect midway on the left femur. A five-hole titanium plate was modeled onto the bone. In 20 animals, methicillin-resistant Staphylococcus aureus (MRSA) was placed on the plate. On day 14, lavage and debridement were performed in all mini-pigs. Ten infected and 10 control minipigs received a sterile seven-hole titanium plate. The other 10 infected minipigs received a seven-hole titanium plate coated with lysostaphin. On day 84, lavage and blood samples were collected again, the minipigs were euthanized, and computed tomography examinations were performed.

Counts of colony-forming units (CFU)

Level of CFU was determined in the lavages on days 14 and 84. Lavages were obtained during debridement. Therefore, 200 μl of the lavage fluid was serially diluted in phosphate-buffered saline (PBS). Four replicates of 10 μl of each dilution were applied to Columbia agar plates containing 5% sheep blood. The plates were incubated at 37 °C for 24 h. Colonies were then counted. Results are expressed as CFU/ml of lavage fluid (quadruplicate preparation).

Radiographic and computer tomographic analysis

The plate position (day 0) and bone healing (day 14 and 84) were controlled radiologically with a standard digital X-ray machine. After sacrificing the animals, the femurs were removed and fixed in 4% formalin.
Image acquisition was performed on a single-source computed tomography (CT) scanner (Somatom Definition Edge, Siemens Healthineers, Forchheim, Germany). A high-resolution CT scan was performed with a detector collimation of 16 × 0.3 mm at 120 kVp. High-resolution multiplanar reformations were reconstructed with a slice thickness of 0.4 mm and a bone kernel in axial, sagittal, and coronal directions. The sizes of all drill holes as well as the total volume of the bone and the callus were measured in the image analysis software syngo.via (Siemens Healthineers, Forchheim, Germany). Furthermore, 3D reconstructions of each bone were made using the local picture archive and communication system (PACS, Sectra IDS 7, Linkoping, Sweden).

Analysis of local and systemic immune responses

For local and systemic immune response, polymorphonuclear neutrophils (PMN) were measured as a percentage of total leukocyte count in lavage and blood using flow cytometry (FACSLytic, BD Pharming™, Heidelberg, Germany) with CD172a (PE Mouse Anti-Pig Monocyte/Granulocyte, BD Pharmingen™, San José, USA) and 6D10 (FITC Granulocytes Monoclonal Antibody, Invitrogen Thermo Fisher Scientific, Waltham, USA) antibodies. Samples were tested in duplicate.

Quantification of IL-6 and IL-17 by ELISA

Interleukin (IL)-6 and IL-17 levels in lavage and serum were determined using a commercially available immunokit (Porcine IL-6 Quantine® ELISA, R&D Systems®, Porcine IL-17, Invitrogen, Thermo Fisher Scientific, Waltham, USA) in a microplate reader (VICTOR X3 Plate Reader, PerkinElmer LAS, Rodgau, Germany). The mean of minimum detectable dose (MDD) of IL-6 was 2.03 pg/ml and MDD of IL-17 14 pg/ml. Samples were tested in duplicate.

Alkaline phosphatase and bone-specific alkaline phosphatase level

The non-specific alkaline phosphatase (ALP Assay Kit, Abnova GmbH, Heidelberg, Germany) and the bone-specific alkaline phosphatase (Porcine bALP ELISA Kit, MyBioSource, San Diego, USA) were measured in lavage and serum at a wavelength of 405 nm after 0 and 4 min (Victor X3, Plate Reader, PerkinElmer LAS, Rodgau, Germany). Samples were tested in duplicate.

Amino-terminal propeptide of type I collagen

Amino-terminal propeptide of type I collagen (PINP) concentration (Porcine procollagen 1N-terminal peptide ELISA Kit, BT Lab, Birmingham, UK) was measured in lavage and serum in a microplate reader (Victor X3, Plate Reader, PerkinElmer LAS, Rodgau, Germany) according to the manufacturer’s instructions. Samples were tested in duplicate.

Statistical methods

All data are expressed as median and scatter dots. Omnibus normality test by D’Agostino and Pearson’s. Data were tested for statistical significance with two-tailed Student’s t-test and Mann–Whitney U test using GraphPad Prism5 (GraphPad Software, San Diego, USA): p values ≤ 0.05 were considered as significant.

Results

Clinical observations

All animals tolerated the surgical procedures very well and returned to their normal activities after anesthesia, eating and drinking independently. One animal in the group with lysostaphin-coated plates had a local multi-infection with Escherichia coli, Streptococcus pyogenes, Streptococcus suis, and Staphylococcus spp., so we excluded the minipig from the experiment. All other 29 animals survived throughout the study period without any plate breakage, fracture, or other adverse events. We could euthanize all minipigs according to the described study protocol.

Low-grade acute osteitis model

The bacterial load in the wound was determined by CFU on days 14 and 84 with an average inoculation CFU of 105. Lavage showed significantly lower CFU on day 84 in infected animals with a lysostaphin-coated plate compared to infected animals with an uncoated plate (p = 0.0411); see Fig. 2. In three animals with a lysostaphin-coated plate, MRSA could no longer be detected on day 84.

Bone healing

Bone healing was checked radiologically in all animals on days 0, 14, and 84. In the infected animals without a lysostaphin plate, excessive callus formation, measured by total bone volume and calcified bone volume, was observed by 3D CT on day 84 (Figs. 3 and 4, Sup 1). This could be inhibited in the infected animals with a lysostaphin-coated plate (p = 0.0164, p = 0.0033). Furthermore, the degree of osteolysis of the screw holes was determined. Here, there was no significant difference in the infected animals with and without lysostaphin-coated plates (p = 0.2673). However, we observed a trend towards a positive effect by a lysostaphin-coated plate (Fig. 5). The examined biochemical markers of bone metabolism ALP and PINP showed no significant differences in the infected animals with and without lysostaphin-coated plates (Sup 2 and 3). Furthermore, no significant difference between ALP and bone-specific ALP (bALP) could be demonstrated.

Immune response

Figure 6 shows a significant difference for IL-17 in serum of minipigs with lysostaphin-coated plates as in the minipigs with uncoated plates on days 0, 14, and 84. Furthermore, there was significant difference of IL-17 in lavage for lysostaphin-coated plates compared to control (p = 0.0021) on day 84.
Further local and systemic immune response analysis showed no significant differences between the infected animals with and without lysostaphin-coated plate for PMN (Fig. 7) as well as for IL-6 (Sup 4). Immune response only showed differences between infection and control groups, and can therefore confirm our osteitis model.

Discussion

Implant-associated infections (IAI) remain one of the greatest challenges in orthopedic and trauma surgery, despite major advances that have been achieved regarding their diagnosis and treatment. Currently, the most important treatment principles for IAI include surgical debridement, implant handling, long-term systemic antibiotics, reconstruction defects of bone and soft tissues, and functional recovery [25]. Fundamental research in vitro and in vivo should be performed to uncover the pathogenesis of this disorder more comprehensively. Here, we can confirm the established, standardized minipig model for examining IAI on the one hand, and the antimicrobial coating using lysostaphin as a possible therapeutic agent in IAI on the other hand.
Key problem of implant infections is the lack of effective therapies. Alternative strategies with antimicrobial enzymes such as lysostaphin could provide new options by killing planktonic and quiescent bacteria as well as bacteria growing in a biofilm [26]. In this study, the implanted titanium plates were dipped in a PDLLA-lysostaphin mixture and air-dried. This dip-drying step was repeated four times to obtain a multi-layer comprising PDLLA and lysostaphin. Other biomaterial strategies to deliver active lysostaphin have primarily focused on surface functionalization, by either passive adsorption [27, 28] or covalent tethering [29, 30]. Johnson et al. postulate that all these techniques, including our own, are effective ways to reduce bacteria at the material surface but may not be practical for settings where infection is already established, or not localized to a material surface [22]. They demonstrate that lysostaphin-delivering hydrogels have greater antibiofilm activity compared with soluble lysostaphin, even in a FRI model. However, these results have so far only been demonstrated for a small animal model (murine model) and are only been tested in an MSSA (UMAS-1) strain [22, 23]. Perhaps, lysostaphin combinations of implant coating and hydrogel application would be promising. To increase lysostaphin stability and retention times at the site of administration, Xue et al. analyzed the lysostaphin delivery using hydroxyapatite/chitosan composite bone cement [31]. Summarized, their study suggested that the lysostaphin-loaded self-setting injectable bone cement released the enzyme in a controlled and effective way. Furthermore, the enzymatic activity was well preserved during the setting and release process. To date, however, these experiments have only been carried out in the subcutaneous tissue of mice, and results in an IAI model are still pending.
Lysostaphin is not the only coating that has been tested in the treatment of patients with IAI from/resulting from medical devices [32]. In the last decade, several studies have investigated the ability of implant surface modifications to minimize bacterial adhesion, inhibit biofilm formation, and provide effective bacterial killing to protect implanted biomaterials [33]. Thereby, we can distinguish (1) antibacterial coatings (passive or active) and (2) modification of the surface of medical implants (physical or chemical) [34]. The lack of a common language and a common outcome set, as well as a large discrepancy between proposed and clinically implemented strategies, complicates evaluation of individual procedures and their comparison. Jeyaraman et al. summarize the current study situation on silver nanoparticles (AgNP) technology and conclude that AgNP has the potential to reduce implant-related infections. Yet, further studies and regulatory guidelines to avoid toxicity in clinical applications are pending.
Current therapeutic concepts require the implant removal in the treatment of osteitis, especially due to the formation of biofilm [35]. However, if the fracture has not healed, an implant replacement should be performed at least. To our knowledge, this is the first animal implant-associated osteitis model, which allows a plate replacement and thus forms a good foundation for future studies.
This study has several limitations. First, in contrast to our previously established mouse model, we also identified a significant number of foreign bacteria in one pig (Escherichia coli, Streptococcus pyogenes, Streptococcus suis, Staphylococcus spp.) when analyzing the bacterial load. Unfortunately, this cannot be avoided due to the pigs’ natural behavior, although we performed a standardized and careful disinfection of the pig skin before the respective operations. Finally, we excluded the pig in which this high number of foreign bacteria was detected from the analyses.
Secondly, the analysis of PMN, IL-6, and IL-17 did not reveal any pioneering findings. This could certainly be related to the chosen measurement times. For animal welfare reasons, the first lavage and blood samples were taken as part of the revision surgery on day 14, relatively late after infection induction. This led to a lower immune response than we expected, even in the infected animals. Compared to our own mouse model and the study of Johnson (both IL determinations were carried out on day 7), the measured IL levels in the present study were only half as high, even in the infected animals. Future studies should provide early assessments (e.g., days 1–6) of immunological parameters.
Thirdly, the analysis of the drill holes revealed no significant difference between the uncoated and the lysostaphin-coated plates, although CT showed significant differences among bone volume and mineralization. This could be attributed to the lysostaphin coating in the area of the screws. Stability of the PDLLA-lysostaphin-coating has not been evaluated so far. During inserting of the self-tapping screws, the coating could be lost due to the forces acting there. Finally, we cannot say with certainty what concentration was present after implantation of the osteosynthesis. Further studies to investigate surface adhesion, particularly in the area of screws, are pending, but planned.
Lastly, animal experiments cannot fully simulate the complex immunological and biomechanical environments of the human body, which limits the conclusions of the study. Going forward into a clinical setting will be challenging.

Conclusion

Based on the presented in vivo study, we can confirm our minipig model for the investigation of implant-associated bone infections, especially when an exchange of the implant should be performed. This enables further advance approaches and therapeutic options to be evaluated using this model.
Moreover, we demonstrate that lysostaphin coating prevents the development of an infection in spite of a bacterial contamination of MRSA and the presence of an implant, normally leading to progressive infection due to biofilm formation. From the clinical perspective, an antimicrobial coating of the osteosynthesis material would be desirable in high-risk cases (e.g., in the treatment of open fractures or in elderly patients with compromised tissue) or even after the infection has been clinically resolved. Future studies should focus on the development of effective coating strategies and the establishment of clinical model.

Acknowledgements

We would like to thank the animal caretakers and doctors of the animal facility of the Heinrich-Heine University Düsseldorf: Zentrale Einrichtung für Tierforschung und wissenschaftliche Tierschutzaufgaben (ZETT), Germany, who have taken care of the animals with great dedication and sacrifice. Furthermore, we thank Prof. Colin R. MacKenzie from the Institute of Medical Microbiology and Hospital Hygiene, Heinrich-Heine University, Duesseldorf, Germany, for providing the bacteria. Personally, I (CD Windolf) would like to thank my technical assistant Christa Wilkens for her tireless efforts both with the animals and in the laboratory, even outside the prescribed working hours.

Declarations

Competing interests

The authors declare no competing interests.
Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://​creativecommons.​org/​licenses/​by/​4.​0/​.

Unsere Produktempfehlungen

e.Med Interdisziplinär

Kombi-Abonnement

Jetzt e.Med zum Sonderpreis bestellen!

Für Ihren Erfolg in Klinik und Praxis - Die beste Hilfe in Ihrem Arbeitsalltag

Mit e.Med Interdisziplinär erhalten Sie Zugang zu allen CME-Fortbildungen und Fachzeitschriften auf SpringerMedizin.de.

Jetzt bestellen und 100 € sparen!

e.Med Orthopädie & Unfallchirurgie

Kombi-Abonnement

Mit e.Med Orthopädie & Unfallchirurgie erhalten Sie Zugang zu CME-Fortbildungen der Fachgebiete, den Premium-Inhalten der dazugehörigen Fachzeitschriften, inklusive einer gedruckten Zeitschrift Ihrer Wahl.

Neuer Inhalt

Print-Titel

Literatur
1.
Zurück zum Zitat Rochford ETJ, Richards RG, Moriarty TF. Influence of material on the development of device-associated infections. Clin Microbiol Infect. 2012;18:1162–7.CrossRefPubMed Rochford ETJ, Richards RG, Moriarty TF. Influence of material on the development of device-associated infections. Clin Microbiol Infect. 2012;18:1162–7.CrossRefPubMed
3.
Zurück zum Zitat Darouiche RO. Treatment of infections associated with surgical implants. N Engl J Med. 2004;350:1422–9.CrossRefPubMed Darouiche RO. Treatment of infections associated with surgical implants. N Engl J Med. 2004;350:1422–9.CrossRefPubMed
4.
Zurück zum Zitat Tong SYC, Davis JS, Eichenberger E, Holland TL, Fowler VG. Staphylococcus aureus infections: epidemiology, pathophysiology, clinical manifestations, and management. Clin Microbiol Rev. 2015;28:603–61.CrossRefPubMedPubMedCentral Tong SYC, Davis JS, Eichenberger E, Holland TL, Fowler VG. Staphylococcus aureus infections: epidemiology, pathophysiology, clinical manifestations, and management. Clin Microbiol Rev. 2015;28:603–61.CrossRefPubMedPubMedCentral
6.
Zurück zum Zitat Arciola CR, Campoccia D, Speziale P, Montanaro L, Costerton JW. Biofilm formation in Staphylococcus implant infections. A review of molecular mechanisms and implications for biofilm-resistant materials. Biomaterials. 2012;33:5967–82.CrossRefPubMed Arciola CR, Campoccia D, Speziale P, Montanaro L, Costerton JW. Biofilm formation in Staphylococcus implant infections. A review of molecular mechanisms and implications for biofilm-resistant materials. Biomaterials. 2012;33:5967–82.CrossRefPubMed
7.
Zurück zum Zitat Arciola CR, Campoccia D, Gamberini S, Baldassarri L, Montanaro L. Prevalence of cna, fnbA and fnbB adhesin genes among Staphylococcus aureus isolates from orthopedic infections associated to different types of implant. FEMS Microbiol Lett. 2005;246:81–6.CrossRefPubMed Arciola CR, Campoccia D, Gamberini S, Baldassarri L, Montanaro L. Prevalence of cna, fnbA and fnbB adhesin genes among Staphylococcus aureus isolates from orthopedic infections associated to different types of implant. FEMS Microbiol Lett. 2005;246:81–6.CrossRefPubMed
8.
Zurück zum Zitat Stewart PS, Costerton JW. Antibiotic resistance of bacteria in biofilms. Lancet. 2001;358:135–8.CrossRefPubMed Stewart PS, Costerton JW. Antibiotic resistance of bacteria in biofilms. Lancet. 2001;358:135–8.CrossRefPubMed
9.
Zurück zum Zitat Costerton JW, Montanaro L, Arciola CR. Biofilm in implant infections: its production and regulation. Int J Artif Organs. 2005;28:1062–8.CrossRefPubMed Costerton JW, Montanaro L, Arciola CR. Biofilm in implant infections: its production and regulation. Int J Artif Organs. 2005;28:1062–8.CrossRefPubMed
10.
Zurück zum Zitat Masters EA, Trombetta RP, de Mesy Bentley KL, Boyce BF, Gill AL, Gill SR, et al. Evolving concepts in bone infection: redefining “biofilm”, “acute vs. chronic osteomyelitis”, “the immune proteome” and “local antibiotic therapy”. Bone Res. 2019;7:20.CrossRefPubMedPubMedCentral Masters EA, Trombetta RP, de Mesy Bentley KL, Boyce BF, Gill AL, Gill SR, et al. Evolving concepts in bone infection: redefining “biofilm”, “acute vs. chronic osteomyelitis”, “the immune proteome” and “local antibiotic therapy”. Bone Res. 2019;7:20.CrossRefPubMedPubMedCentral
11.
Zurück zum Zitat da Silva RAG, Afonina I, Kline KA. Eradicating biofilm infections: an update on current and prospective approaches. Curr Opin Microbiol. 2021;63:117–25.CrossRefPubMed da Silva RAG, Afonina I, Kline KA. Eradicating biofilm infections: an update on current and prospective approaches. Curr Opin Microbiol. 2021;63:117–25.CrossRefPubMed
12.
Zurück zum Zitat Pietrocola G, Campoccia D, Motta C, Montanaro L, Arciola CR, Speziale P. Colonization and infection of indwelling medical devices by Staphylococcus aureus with an emphasis on orthopedic implants. Int J Mol Sci. 2022;23:5958.CrossRefPubMedPubMedCentral Pietrocola G, Campoccia D, Motta C, Montanaro L, Arciola CR, Speziale P. Colonization and infection of indwelling medical devices by Staphylococcus aureus with an emphasis on orthopedic implants. Int J Mol Sci. 2022;23:5958.CrossRefPubMedPubMedCentral
13.
Zurück zum Zitat Rodríguez-Merchán EC, Davidson DJ, Liddle AD. Recent strategies to combat infections from biofilm-forming bacteria on orthopaedic implants. Int J Mol Sci. 2021;22:10243.CrossRefPubMedPubMedCentral Rodríguez-Merchán EC, Davidson DJ, Liddle AD. Recent strategies to combat infections from biofilm-forming bacteria on orthopaedic implants. Int J Mol Sci. 2021;22:10243.CrossRefPubMedPubMedCentral
14.
Zurück zum Zitat Campoccia D, Montanaro L, Arciola CR. A review of the biomaterials technologies for infection-resistant surfaces. Biomaterials. 2013;34:8533–54.CrossRefPubMed Campoccia D, Montanaro L, Arciola CR. A review of the biomaterials technologies for infection-resistant surfaces. Biomaterials. 2013;34:8533–54.CrossRefPubMed
15.
Zurück zum Zitat Alt V. Antimicrobial coated implants in trauma and orthopaedics-a clinical review and risk-benefit analysis. Injury. 2017;48:599–607.CrossRefPubMed Alt V. Antimicrobial coated implants in trauma and orthopaedics-a clinical review and risk-benefit analysis. Injury. 2017;48:599–607.CrossRefPubMed
16.
Zurück zum Zitat Zimmerli W. Clinical presentation and treatment of orthopaedic implant-associated infection. J Intern Med. 2014;276:111–9.CrossRefPubMed Zimmerli W. Clinical presentation and treatment of orthopaedic implant-associated infection. J Intern Med. 2014;276:111–9.CrossRefPubMed
17.
Zurück zum Zitat Filipović U, Dahmane RG, Ghannouchi S, Zore A, Bohinc K. Bacterial adhesion on orthopedic implants. Adv Colloid Interface Sci. 2020;283: 102228.CrossRefPubMed Filipović U, Dahmane RG, Ghannouchi S, Zore A, Bohinc K. Bacterial adhesion on orthopedic implants. Adv Colloid Interface Sci. 2020;283: 102228.CrossRefPubMed
18.
Zurück zum Zitat Arciola CR, Alvi FI, An YH, Campoccia D, Montanaro L. Implant infection and infection resistant materials: a mini review. Int J Artif Organs. 2005;28:1119–25.CrossRefPubMed Arciola CR, Alvi FI, An YH, Campoccia D, Montanaro L. Implant infection and infection resistant materials: a mini review. Int J Artif Organs. 2005;28:1119–25.CrossRefPubMed
19.
Zurück zum Zitat Windolf CD, Lögters T, Scholz M, Windolf J, Flohé S. Lysostaphin-coated titan-implants preventing localized osteitis by Staphylococcus aureus in a mouse model. PloS One. 2014;9(12):e115940.CrossRefPubMedPubMedCentral Windolf CD, Lögters T, Scholz M, Windolf J, Flohé S. Lysostaphin-coated titan-implants preventing localized osteitis by Staphylococcus aureus in a mouse model. PloS One. 2014;9(12):e115940.CrossRefPubMedPubMedCentral
20.
Zurück zum Zitat Jayakumar J, Kumar VA, Biswas L, Biswas R. Therapeutic applications of lysostaphin against Staphylococcus aureus. J Appl Microbiol. 2021;131:1072–82.CrossRefPubMed Jayakumar J, Kumar VA, Biswas L, Biswas R. Therapeutic applications of lysostaphin against Staphylococcus aureus. J Appl Microbiol. 2021;131:1072–82.CrossRefPubMed
21.
Zurück zum Zitat Kokai-Kun JF, Chanturiya T, Mond JJ. Lysostaphin eradicates established Staphylococcus aureus biofilms in jugular vein catheterized mice. J Antimicrob Chemother. 2009;64(1):94–100.CrossRefPubMed Kokai-Kun JF, Chanturiya T, Mond JJ. Lysostaphin eradicates established Staphylococcus aureus biofilms in jugular vein catheterized mice. J Antimicrob Chemother. 2009;64(1):94–100.CrossRefPubMed
22.
Zurück zum Zitat Johnson CT, Wroe JA, Agarwal R, Martin KE, Guldberg RE, Donlan RM, et al. Hydrogel delivery of lysostaphin eliminates orthopedic implant infection by Staphylococcus aureus and supports fracture healing. Proc Natl Acad Sci U S A. 2018;115:E4960–9.CrossRefPubMedPubMedCentral Johnson CT, Wroe JA, Agarwal R, Martin KE, Guldberg RE, Donlan RM, et al. Hydrogel delivery of lysostaphin eliminates orthopedic implant infection by Staphylococcus aureus and supports fracture healing. Proc Natl Acad Sci U S A. 2018;115:E4960–9.CrossRefPubMedPubMedCentral
23.
Zurück zum Zitat Johnson CT, Sok MCP, Martin KE, Kalelkar PP, Caplin JD, Botchwey EA, et al. Lysostaphin and BMP-2 co-delivery reduces S. aureus infection and regenerates critical-sized segmental bone defects. Sci Adv. 2019;5:eaaw1228.CrossRefPubMedPubMedCentral Johnson CT, Sok MCP, Martin KE, Kalelkar PP, Caplin JD, Botchwey EA, et al. Lysostaphin and BMP-2 co-delivery reduces S. aureus infection and regenerates critical-sized segmental bone defects. Sci Adv. 2019;5:eaaw1228.CrossRefPubMedPubMedCentral
24.
Zurück zum Zitat Jaekel C, Windolf CD, Sager M, Wollschläger LM, Hoffmanns M, Grassmann JP. Plate-associated localized osteitis in mini-pig by biofilm-forming methicillin-resistant Staphylococcus aureus (MRSA): establishment of a novel experimental model. Eur J Trauma Emerg Surg. 2022;48:3279–85.CrossRefPubMedPubMedCentral Jaekel C, Windolf CD, Sager M, Wollschläger LM, Hoffmanns M, Grassmann JP. Plate-associated localized osteitis in mini-pig by biofilm-forming methicillin-resistant Staphylococcus aureus (MRSA): establishment of a novel experimental model. Eur J Trauma Emerg Surg. 2022;48:3279–85.CrossRefPubMedPubMedCentral
26.
Zurück zum Zitat Wu JA, Kusuma C, Mond JJ, Kokai-Kun JF. Lysostaphin disrupts Staphylococcus aureus and Staphylococcus epidermidis biofilms on artificial surfaces. Antimicrob Agents Chemother. 2003;47:3407–14.CrossRefPubMedPubMedCentral Wu JA, Kusuma C, Mond JJ, Kokai-Kun JF. Lysostaphin disrupts Staphylococcus aureus and Staphylococcus epidermidis biofilms on artificial surfaces. Antimicrob Agents Chemother. 2003;47:3407–14.CrossRefPubMedPubMedCentral
27.
Zurück zum Zitat Kokai-Kun JF, Chanturiya T, Mond JJ. Lysostaphin eradicates established Staphylococcus aureus biofilms in jugular vein catheterized mice. J Antimicrob Chemother. 2009;64:94–100.CrossRefPubMed Kokai-Kun JF, Chanturiya T, Mond JJ. Lysostaphin eradicates established Staphylococcus aureus biofilms in jugular vein catheterized mice. J Antimicrob Chemother. 2009;64:94–100.CrossRefPubMed
28.
Zurück zum Zitat Shah A, Mond J, Walsh S. Lysostaphin-coated catheters eradicate Staphylococccus aureus challenge and block surface colonization. Antimicrob Agents Chemother. 2004;48:2704–7.CrossRefPubMedPubMedCentral Shah A, Mond J, Walsh S. Lysostaphin-coated catheters eradicate Staphylococccus aureus challenge and block surface colonization. Antimicrob Agents Chemother. 2004;48:2704–7.CrossRefPubMedPubMedCentral
29.
Zurück zum Zitat Miao J, Pangule RC, Paskaleva EE, Hwang EE, Kane RS, Linhardt RJ, et al. Lysostaphin-functionalized cellulose fibers with antistaphylococcal activity for wound healing applications. Biomaterials. 2011;32:9557–67.CrossRefPubMed Miao J, Pangule RC, Paskaleva EE, Hwang EE, Kane RS, Linhardt RJ, et al. Lysostaphin-functionalized cellulose fibers with antistaphylococcal activity for wound healing applications. Biomaterials. 2011;32:9557–67.CrossRefPubMed
30.
Zurück zum Zitat Yeroslavsky G, Girshevitz O, Foster-Frey J, Donovan DM, Rahimipour S. Antibacterial and antibiofilm surfaces through polydopamine-assisted immobilization of lysostaphin as an antibacterial enzyme. Langmuir. 2015;31:1064–73.CrossRefPubMed Yeroslavsky G, Girshevitz O, Foster-Frey J, Donovan DM, Rahimipour S. Antibacterial and antibiofilm surfaces through polydopamine-assisted immobilization of lysostaphin as an antibacterial enzyme. Langmuir. 2015;31:1064–73.CrossRefPubMed
31.
Zurück zum Zitat Xue B, Zhang C, Wang Y, Wang J, Zhang J, Lu M, et al. A novel controlled-release system for antibacterial enzyme lysostaphin delivery using hydroxyapatite/chitosan composite bone cement. PLoS ONE. 2014;9: e113797.CrossRefPubMedPubMedCentral Xue B, Zhang C, Wang Y, Wang J, Zhang J, Lu M, et al. A novel controlled-release system for antibacterial enzyme lysostaphin delivery using hydroxyapatite/chitosan composite bone cement. PLoS ONE. 2014;9: e113797.CrossRefPubMedPubMedCentral
32.
Zurück zum Zitat Folliero V, Franci G, Dell’Annunziata F, Giugliano R, Foglia F, Sperlongano R, et al. Evaluation of antibiotic resistance and biofilm production among clinical strain isolated from medical devices. Int J Microbiol. 2021;2021:9033278.CrossRefPubMedPubMedCentral Folliero V, Franci G, Dell’Annunziata F, Giugliano R, Foglia F, Sperlongano R, et al. Evaluation of antibiotic resistance and biofilm production among clinical strain isolated from medical devices. Int J Microbiol. 2021;2021:9033278.CrossRefPubMedPubMedCentral
33.
Zurück zum Zitat Romanò CL, Scarponi S, Gallazzi E, Romanò D, Drago L. Antibacterial coating of implants in orthopaedics and trauma: a classification proposal in an evolving panorama. J Orthop Surg Res. 2015;10:157.CrossRefPubMedPubMedCentral Romanò CL, Scarponi S, Gallazzi E, Romanò D, Drago L. Antibacterial coating of implants in orthopaedics and trauma: a classification proposal in an evolving panorama. J Orthop Surg Res. 2015;10:157.CrossRefPubMedPubMedCentral
34.
Zurück zum Zitat Li P, Yin R, Cheng J, Lin J. Bacterial biofilm formation on biomaterials and approaches to its treatment and prevention. Int J Mol Sci. 2023;24:11680.CrossRefPubMedPubMedCentral Li P, Yin R, Cheng J, Lin J. Bacterial biofilm formation on biomaterials and approaches to its treatment and prevention. Int J Mol Sci. 2023;24:11680.CrossRefPubMedPubMedCentral
35.
Zurück zum Zitat Depypere M, Morgenstern M, Kuehl R, Senneville E, Moriarty TF, Obremskey WT, et al. Pathogenesis and management of fracture-related infection. Clin Microbiol Infect. 2020;26:572–8.CrossRefPubMed Depypere M, Morgenstern M, Kuehl R, Senneville E, Moriarty TF, Obremskey WT, et al. Pathogenesis and management of fracture-related infection. Clin Microbiol Infect. 2020;26:572–8.CrossRefPubMed
Metadaten
Titel
Efficacy of lysostaphin-coated titanium plates on implant-associated MRSA osteitis in minipigs
verfasst von
Carina Jaekel
Ceylan D. Windolf
Dan Bieler
Lisa Oezel
Lars F. Seiler
Felix N. Lakomek
Christoph Beyersdorf
Jann Mertens
Andrea Steuwe
Joachim Windolf
Jan P. Grassmann
Publikationsdatum
24.01.2024
Verlag
Springer Berlin Heidelberg
Erschienen in
European Journal of Trauma and Emergency Surgery
Print ISSN: 1863-9933
Elektronische ISSN: 1863-9941
DOI
https://doi.org/10.1007/s00068-024-02448-4

Arthropedia

Grundlagenwissen der Arthroskopie und Gelenkchirurgie. Erweitert durch Fallbeispiele, Videos und Abbildungen. 
» Jetzt entdecken

Knie-TEP: Kein Vorteil durch antibiotikahaltigen Knochenzement

29.05.2024 Periprothetische Infektionen Nachrichten

Zur Zementierung einer Knie-TEP wird in Deutschland zu über 98% Knochenzement verwendet, der mit einem Antibiotikum beladen ist. Ob er wirklich besser ist als Zement ohne Antibiotikum, kann laut Registerdaten bezweifelt werden.

Häusliche Gewalt in der orthopädischen Notaufnahme oft nicht erkannt

28.05.2024 Häusliche Gewalt Nachrichten

In der Notaufnahme wird die Chance, Opfer von häuslicher Gewalt zu identifizieren, von Orthopäden und Orthopädinnen offenbar zu wenig genutzt. Darauf deuten die Ergebnisse einer Fragebogenstudie an der Sahlgrenska-Universität in Schweden hin.

Fehlerkultur in der Medizin – Offenheit zählt!

28.05.2024 Fehlerkultur Podcast

Darüber reden und aus Fehlern lernen, sollte das Motto in der Medizin lauten. Und zwar nicht nur im Sinne der Patientensicherheit. Eine negative Fehlerkultur kann auch die Behandelnden ernsthaft krank machen, warnt Prof. Dr. Reinhard Strametz. Ein Plädoyer und ein Leitfaden für den offenen Umgang mit kritischen Ereignissen in Medizin und Pflege.

Mehr Frauen im OP – weniger postoperative Komplikationen

21.05.2024 Allgemeine Chirurgie Nachrichten

Ein Frauenanteil von mindestens einem Drittel im ärztlichen Op.-Team war in einer großen retrospektiven Studie aus Kanada mit einer signifikanten Reduktion der postoperativen Morbidität assoziiert.

Update Orthopädie und Unfallchirurgie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.