Erschienen in:
25.09.2019 | Original articles
Avoiding implantation of a cardioverter-defibrillator by bridging with wearable defibrillator vest
verfasst von:
Norbert Klein, MD, Thomas Kuntz, Stefan Dhein, MD
Erschienen in:
Herz
|
Ausgabe 2/2021
Einloggen, um Zugang zu erhalten
Abstract
Background
Patients with a left ventricular ejection fraction (LVEF) ≤35% should be protected from sudden cardiac death with an implantable cardioverter-defibrillator (ICD). The onset of the effect of optimal medical therapy (OMT) is unclear, and a wearable cardioverter-defibrillator (WCD) can bridge this period.
Patients and methods
Our study analyzed 104 patients (age, 68.9 ± 11.7 years; 81% [84/104] male) whose first diagnosis included an LVEF <35%. After exclusion of reversible causes for LVEF reduction and initiation/adjustment of the OMT, the WCD was employed. The LVEF and indication for ICD were re-evaluated after 62 ± 36 days. The LVEF development and implantation rate were correlated with underlying disease (ischemic [ICM] or nonischemic cardiomyopathy [NICM]), comorbidities, and age/gender.
Results
The wearing time of the WCD was 22.8 ± 1.9 h/day. An LVEF improvement from 28.5 ± 6.4% to 40 ± 11.7% was achieved through OMT (p < 0.0001). An improvement in LVEF of up to more than 35% was achieved in 66 of 104 patients (63%), and only 37% of patients were subsequently given an ICD. This affected 41% of patients with ICM and 30% of patients with NICM (p = 0.205). Notably, no ICD interventions were observed over 362 ± 89.5 days after implantation in the ICD-receiver group.
Conclusion
The indication for ICD can be re-evaluated after 2 months. Patients with NICM respond better to OMT compared with ICM patients. The LVEF recovered to >35% in >60% of cases.