Skip to main content
Erschienen in: European Archives of Oto-Rhino-Laryngology 5/2023

01.11.2022 | Otology

A comparative study of audiological outcomes and compliance between the Osia system and other bone conduction hearing implants

verfasst von: Yehree Kim, Goun Choe, Heonjeong Oh, Byung Yoon Choi

Erschienen in: European Archives of Oto-Rhino-Laryngology | Ausgabe 5/2023

Einloggen, um Zugang zu erhalten

Abstract

Purpose

To examine the subjective and objective audiological benefits of the Osia system compared to devices commonly implanted prior to the introduction of this system.

Methods

Osia recipients with either conductive hearing loss (CHL/MHL) (n = 9) or single-sided deafness (SSD) (n = 8) who underwent surgery from February 2021 to March 2022 were prospectively recruited. The audiological outcomes and usage rate of Osia implantees were compared with those of retrospectively recruited patients implanted with other devices (n = 50). The subjective satisfaction of the Osia implantees was also evaluated through questionnaires.

Results

All users of the Osia system were classified as regular users. In the CHL/MHL group, the effective gain of the Osia system (11.1 ± 14.9 dB) surpassed that of the Baha and Bonebridge (− 2.7 ± 12.6 dB) at 2 kHz (p = 0.01, Mann–Whitney U test). Among the devices, the Osia system tended to tolerate the worst bone conduction thresholds, up to the level of 61 dB. In the SSD group, the functional gain of Osia at 4 kHz (37.5 ± 3.1 dB) was higher than that of the Baha and Bonebridge group (26.9 ± 3.0 dB) (p = 0.05, Mann–Whitney U test).

Conclusion

The Osia system yielded larger audiological gain than the Baha Attract and Bonebridge devices, especially at high frequencies, leading to substantially higher compliance. The Osia system tended to have the strongest tolerance to aggravated bone conduction thresholds among the available transcutaneous bone conduction hearing implants. Therefore, the Osia system could potentially be a good option for CHL/MHL patients with bone conduction thresholds of 50 dB HL or more, as well as patients with SSD.
Anhänge
Nur mit Berechtigung zugänglich
Literatur
1.
Zurück zum Zitat Kunst SJ, Leijendeckers JM, Mylanus EA, Hol MK, Snik AF, Cremers CWJO (2008) Bone-anchored hearing aid system application for unilateral congenital conductive hearing impairment: audiometric results. Neurotology 29:2–7CrossRef Kunst SJ, Leijendeckers JM, Mylanus EA, Hol MK, Snik AF, Cremers CWJO (2008) Bone-anchored hearing aid system application for unilateral congenital conductive hearing impairment: audiometric results. Neurotology 29:2–7CrossRef
2.
Zurück zum Zitat Tietze L, Papsin B (2001) Utilization of bone-anchored hearing aids in children. Int J Pediatric Otorhinolaryngol 58:75–80CrossRef Tietze L, Papsin B (2001) Utilization of bone-anchored hearing aids in children. Int J Pediatric Otorhinolaryngol 58:75–80CrossRef
3.
Zurück zum Zitat Goldstein MR, Bourn S, Jacob A (2021) Early Osia® 2 bone conduction hearing implant experience: nationwide controlled-market release data and single-center outcomes. Am J Otolaryngol 42:102818CrossRefPubMed Goldstein MR, Bourn S, Jacob A (2021) Early Osia® 2 bone conduction hearing implant experience: nationwide controlled-market release data and single-center outcomes. Am J Otolaryngol 42:102818CrossRefPubMed
4.
Zurück zum Zitat You P, Choi A, Drob J, Hunsaker SM, Liu Y-CC, Silva RJO (2022) Early outcomes of a new active transcutaneous bone conduction implant in pediatric patients. Neurotology 43:212–218CrossRef You P, Choi A, Drob J, Hunsaker SM, Liu Y-CC, Silva RJO (2022) Early outcomes of a new active transcutaneous bone conduction implant in pediatric patients. Neurotology 43:212–218CrossRef
5.
Zurück zum Zitat Rauch A-K, Wesarg T, Aschendorff A, Speck I, Arndt S (2021) Long-term data of the new transcutaneous partially implantable bone conduction hearing system Osia®. Eur Arch Oto-Rhino-Laryngol 279:1–10 Rauch A-K, Wesarg T, Aschendorff A, Speck I, Arndt S (2021) Long-term data of the new transcutaneous partially implantable bone conduction hearing system Osia®. Eur Arch Oto-Rhino-Laryngol 279:1–10
6.
Zurück zum Zitat Edmiston R, Aggarwal R, Green K (2015) Bone conduction implants–a rapidly developing field. J Laryngol Otol 129:936–940CrossRefPubMed Edmiston R, Aggarwal R, Green K (2015) Bone conduction implants–a rapidly developing field. J Laryngol Otol 129:936–940CrossRefPubMed
8.
Zurück zum Zitat Goycoolea M, Ribalta G, Tocornal F, Levy R, Alarcón P, Bryman M, Cagnacci B, Catenacci C, Oyanguren V, Vilches I (2020) Clinical performance of the Osia™ system, a new active osseointegrated implant system Results from a prospective clinical investigation. Acta Oto-Laryngol 140:212–219CrossRef Goycoolea M, Ribalta G, Tocornal F, Levy R, Alarcón P, Bryman M, Cagnacci B, Catenacci C, Oyanguren V, Vilches I (2020) Clinical performance of the Osia™ system, a new active osseointegrated implant system Results from a prospective clinical investigation. Acta Oto-Laryngol 140:212–219CrossRef
10.
Zurück zum Zitat Han JJ, Park H-R, Song J-J, Koo J-W, Choi BY (2020) A comparison study of audiological outcome and compliance of bone conduction implantable hearing implants. Eur Arch Oto-Rhino-Laryngol 277:3003–3012CrossRef Han JJ, Park H-R, Song J-J, Koo J-W, Choi BY (2020) A comparison study of audiological outcome and compliance of bone conduction implantable hearing implants. Eur Arch Oto-Rhino-Laryngol 277:3003–3012CrossRef
11.
Zurück zum Zitat Brooks D (1985) Factors relating to the under-use of postaural hearing aids. Br J Audiol 19:211–217CrossRefPubMed Brooks D (1985) Factors relating to the under-use of postaural hearing aids. Br J Audiol 19:211–217CrossRefPubMed
12.
Zurück zum Zitat Rigato C, Reinfeldt S, Håkansson B, Jansson K-JF, Hol MK, Eeg-Olofsson M (2016) Audiometric comparison between the first patients with the transcutaneous bone conduction implant and matched percutaneous bone anchored hearing device users. Otol Neurotol 37:1381–1387CrossRefPubMed Rigato C, Reinfeldt S, Håkansson B, Jansson K-JF, Hol MK, Eeg-Olofsson M (2016) Audiometric comparison between the first patients with the transcutaneous bone conduction implant and matched percutaneous bone anchored hearing device users. Otol Neurotol 37:1381–1387CrossRefPubMed
13.
Zurück zum Zitat Carlsson PU, Håkansson BE (1997) The bone-anchored hearing aid: reference quantities and functional gain. Ear Hear 18:34–41CrossRefPubMed Carlsson PU, Håkansson BE (1997) The bone-anchored hearing aid: reference quantities and functional gain. Ear Hear 18:34–41CrossRefPubMed
14.
Zurück zum Zitat Busch S, Lenarz T, Maier H (2016) Comparison of alternative coupling methods of the vibrant soundbridge floating mass transducer. Audiol Neurotol 21:347–355CrossRef Busch S, Lenarz T, Maier H (2016) Comparison of alternative coupling methods of the vibrant soundbridge floating mass transducer. Audiol Neurotol 21:347–355CrossRef
15.
Zurück zum Zitat Iseri M, Orhan KS, Tuncer U, Kara A, Durgut M, Guldiken Y, Surmelioglu O (2015) Transcutaneous bone-anchored hearing aids versus percutaneous ones: multicenter comparative clinical study. Otol Neurol 36:849–853CrossRef Iseri M, Orhan KS, Tuncer U, Kara A, Durgut M, Guldiken Y, Surmelioglu O (2015) Transcutaneous bone-anchored hearing aids versus percutaneous ones: multicenter comparative clinical study. Otol Neurol 36:849–853CrossRef
16.
Zurück zum Zitat Kim G, Ju HM, Lee SH, Kim H-S, Kwon JA, Seo Y (2017) Efficacy of bone-anchored hearing aids in single-sided deafness: a systematic review. Otol Neurol 38:473–483CrossRef Kim G, Ju HM, Lee SH, Kim H-S, Kwon JA, Seo Y (2017) Efficacy of bone-anchored hearing aids in single-sided deafness: a systematic review. Otol Neurol 38:473–483CrossRef
17.
Zurück zum Zitat Andersen HT, Schrøder SA, Bonding P (2006) Unilateral deafness after acoustic neuroma surgery: subjective hearing handicap and the effect of the bone-anchored hearing aid. Otol Neurol 27:809–814CrossRef Andersen HT, Schrøder SA, Bonding P (2006) Unilateral deafness after acoustic neuroma surgery: subjective hearing handicap and the effect of the bone-anchored hearing aid. Otol Neurol 27:809–814CrossRef
18.
Zurück zum Zitat Snapp HA, Holt FD, Liu X, Rajguru SM (2017) Comparison of speech in noise and localization benefits in unilateral hearing loss subjects using contralateral routing of signal hearing aids or bone anchored implants. Otol Neurotol 38:11CrossRefPubMedPubMedCentral Snapp HA, Holt FD, Liu X, Rajguru SM (2017) Comparison of speech in noise and localization benefits in unilateral hearing loss subjects using contralateral routing of signal hearing aids or bone anchored implants. Otol Neurotol 38:11CrossRefPubMedPubMedCentral
19.
Zurück zum Zitat Finbow J, Bance M, Aiken S, Gulliver M, Verge J, Caissie R (2015) A comparison between wireless CROS and bone-anchored hearing devices for single-sided deafness: a pilot study. Otol Neruol 36:819–825CrossRef Finbow J, Bance M, Aiken S, Gulliver M, Verge J, Caissie R (2015) A comparison between wireless CROS and bone-anchored hearing devices for single-sided deafness: a pilot study. Otol Neruol 36:819–825CrossRef
20.
Zurück zum Zitat Shaw EA (1974) The external ear. Auditory system. Springer, New York, pp 455–490CrossRef Shaw EA (1974) The external ear. Auditory system. Springer, New York, pp 455–490CrossRef
Metadaten
Titel
A comparative study of audiological outcomes and compliance between the Osia system and other bone conduction hearing implants
verfasst von
Yehree Kim
Goun Choe
Heonjeong Oh
Byung Yoon Choi
Publikationsdatum
01.11.2022
Verlag
Springer Berlin Heidelberg
Erschienen in
European Archives of Oto-Rhino-Laryngology / Ausgabe 5/2023
Print ISSN: 0937-4477
Elektronische ISSN: 1434-4726
DOI
https://doi.org/10.1007/s00405-022-07715-x

Weitere Artikel der Ausgabe 5/2023

European Archives of Oto-Rhino-Laryngology 5/2023 Zur Ausgabe

Erhebliches Risiko für Kehlkopfkrebs bei mäßiger Dysplasie

29.05.2024 Larynxkarzinom Nachrichten

Fast ein Viertel der Personen mit mäßig dysplastischen Stimmlippenläsionen entwickelt einen Kehlkopftumor. Solche Personen benötigen daher eine besonders enge ärztliche Überwachung.

Hörschwäche erhöht Demenzrisiko unabhängig von Beta-Amyloid

29.05.2024 Hörstörungen Nachrichten

Hört jemand im Alter schlecht, nimmt das Hirn- und Hippocampusvolumen besonders schnell ab, was auch mit einem beschleunigten kognitiven Abbau einhergeht. Und diese Prozesse scheinen sich unabhängig von der Amyloidablagerung zu ereignen.

„Übersichtlicher Wegweiser“: Lauterbachs umstrittener Klinik-Atlas ist online

17.05.2024 Klinik aktuell Nachrichten

Sie sei „ethisch geboten“, meint Gesundheitsminister Karl Lauterbach: mehr Transparenz über die Qualität von Klinikbehandlungen. Um sie abzubilden, lässt er gegen den Widerstand vieler Länder einen virtuellen Klinik-Atlas freischalten.

Betalaktam-Allergie: praxisnahes Vorgehen beim Delabeling

16.05.2024 Pädiatrische Allergologie Nachrichten

Die große Mehrheit der vermeintlichen Penicillinallergien sind keine. Da das „Etikett“ Betalaktam-Allergie oft schon in der Kindheit erworben wird, kann ein frühzeitiges Delabeling lebenslange Vorteile bringen. Ein Team von Pädiaterinnen und Pädiatern aus Kanada stellt vor, wie sie dabei vorgehen.

Update HNO

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert – ganz bequem per eMail.