Skip to main content
Erschienen in: Current Cardiovascular Imaging Reports 5/2011

01.10.2011

Evaluation of Atrial and Ventricular Septal Defects with Real-Time Three-Dimensional Echocardiography: Current Status and Literature Review

verfasst von: David A. Roberson, Vivian Wei Cui

Erschienen in: Current Cardiovascular Imaging Reports | Ausgabe 5/2011

Einloggen, um Zugang zu erhalten

Abstract

Within this report we present a state of the art assessment of the status of 3D echocardiographic imaging (3D echo) of atrial septal defect (ASD) and ventricular septal defect (VSD). After a brief literature review of past studies, we delve into more recent developments in greater detail. For ASD we focus on new developments and reports regarding real-time transesophageal echocardiography. For VSD there have been no recent reports in the last 2 years dealing with new advances in 3D echo of VSD by either transthoracic or transesophageal approaches. Therefore, we present our experience in 3D echo of VSD by both methods. The literature is far from replete on this subject; therefore, a significant portion of this report is based on the authors’ personal experience using 3D echo in over 200 cases with ASD, VSD, or both lesions in children and adults. A collection of representative reference 3D echoes of ASD and VSD are presented to serve as a review of the anatomic variations which the echocardiographer and sonographer are likely to encounter.
Literatur
1.
Zurück zum Zitat Rivera JM, Siu SC, Handschumacher MD, et al. Three-dimensional reconstruction of ventricular septal defects: validation studies and in vivo feasibility. J Am Coll Cardiol. 1994;23:201–8.PubMedCrossRef Rivera JM, Siu SC, Handschumacher MD, et al. Three-dimensional reconstruction of ventricular septal defects: validation studies and in vivo feasibility. J Am Coll Cardiol. 1994;23:201–8.PubMedCrossRef
2.
Zurück zum Zitat Lang RM, Mor-Avi V, Sugeng L, et al. Three-dimensional echocardiography: the benefits of the additional dimension. J Am Coll Cardiol. 2006;48:2053–69.PubMedCrossRef Lang RM, Mor-Avi V, Sugeng L, et al. Three-dimensional echocardiography: the benefits of the additional dimension. J Am Coll Cardiol. 2006;48:2053–69.PubMedCrossRef
3.
Zurück zum Zitat Lai WW, Geva T, Shirali GS, et al. Guidelines and standards for performance of a pediatric echocardiogram: a report from the task force of the pediatric council of the American society of echocardiography. J Am Soc Echocardiogr. 2006;19:1413–30.PubMedCrossRef Lai WW, Geva T, Shirali GS, et al. Guidelines and standards for performance of a pediatric echocardiogram: a report from the task force of the pediatric council of the American society of echocardiography. J Am Soc Echocardiogr. 2006;19:1413–30.PubMedCrossRef
4.
Zurück zum Zitat Hoffman JIE, Kaplan S. The incidence of congenital heart disease. J Am Coll Cardiol. 2002;39:1890–900.PubMedCrossRef Hoffman JIE, Kaplan S. The incidence of congenital heart disease. J Am Coll Cardiol. 2002;39:1890–900.PubMedCrossRef
5.
Zurück zum Zitat Marx GR, Fulton DR, Pandian NG, et al. Delineation of site, relative size and dynamic geometry of atrial septal defects by real-time three-dimensional echocardiography. J Am Coll Cardiol. 1995;2:482–90.CrossRef Marx GR, Fulton DR, Pandian NG, et al. Delineation of site, relative size and dynamic geometry of atrial septal defects by real-time three-dimensional echocardiography. J Am Coll Cardiol. 1995;2:482–90.CrossRef
6.
Zurück zum Zitat Magni G, Cao QL, Sugeng L, et al. Volume-rendered, three-dimensional echocardiographic determination of the size, shape, and position of atrial septal defects: validation in an in vitro model. Am Heart J. 1996;132:376–81.PubMedCrossRef Magni G, Cao QL, Sugeng L, et al. Volume-rendered, three-dimensional echocardiographic determination of the size, shape, and position of atrial septal defects: validation in an in vitro model. Am Heart J. 1996;132:376–81.PubMedCrossRef
7.
Zurück zum Zitat Acar P, Saliba Z, Bonhoeffer P, et al. Influence of atrial sepal defect anatomy in patient selection and assessment of closure with the cardioseal device. Eur Heart J. 2000;21:573–81.PubMedCrossRef Acar P, Saliba Z, Bonhoeffer P, et al. Influence of atrial sepal defect anatomy in patient selection and assessment of closure with the cardioseal device. Eur Heart J. 2000;21:573–81.PubMedCrossRef
8.
Zurück zum Zitat Cao QL, Radtke W, Berger F, et al. Transcatheter closure of multiple atrial septal defects. Eur Heart J. 2000;21:941–7.PubMedCrossRef Cao QL, Radtke W, Berger F, et al. Transcatheter closure of multiple atrial septal defects. Eur Heart J. 2000;21:941–7.PubMedCrossRef
9.
Zurück zum Zitat Van den Bosch AE, Harkel DJT, McGhie JS, et al. Characterization of atrial septal defect assessed by real-time 3-dimensional echocardiography. J Am Soc Echocardiogr. 2006;19:815–21.PubMedCrossRef Van den Bosch AE, Harkel DJT, McGhie JS, et al. Characterization of atrial septal defect assessed by real-time 3-dimensional echocardiography. J Am Soc Echocardiogr. 2006;19:815–21.PubMedCrossRef
10.
Zurück zum Zitat • Taniguchi M, Akagi T, Watanabe N, Okamoto Y, Nakagawa K, Kijima Y, Toh N, Ohtsuki S, Kusano K, Sano S. Application of real-time three-dimensional transesophageal echocardiography using a matrix array probe for trans-catheter closure of atrial septal defect. J Am Soc Echocardiogr 2009;22:1114–20. This article is the first detailed report of 3D TEE during ASD device closure.PubMedCrossRef • Taniguchi M, Akagi T, Watanabe N, Okamoto Y, Nakagawa K, Kijima Y, Toh N, Ohtsuki S, Kusano K, Sano S. Application of real-time three-dimensional transesophageal echocardiography using a matrix array probe for trans-catheter closure of atrial septal defect. J Am Soc Echocardiogr 2009;22:1114–20. This article is the first detailed report of 3D TEE during ASD device closure.PubMedCrossRef
11.
Zurück zum Zitat •• Faletra FF, Ho SY, Auricchio A. Anatomy of right atrial structures by real-time 3D transesophageal echocardiography J Am Coll Cardiol Img. 2010;3:966–975. This report describes and illustrates in detail a 3D TEE imaging protocol and the anatomy of the right atrium and atrial septum with matched pathology specimens. •• Faletra FF, Ho SY, Auricchio A. Anatomy of right atrial structures by real-time 3D transesophageal echocardiography J Am Coll Cardiol Img. 2010;3:966–975. This report describes and illustrates in detail a 3D TEE imaging protocol and the anatomy of the right atrium and atrial septum with matched pathology specimens.
12.
Zurück zum Zitat •• Pushparajah K, Owen I. Miller OI, Simpson JM. 3D Echocardiography of the atrial septum: anatomical features and landmarks for the echocardiographer. J Am Coll Cardiol Img. 2010;3:981–984. This article includes a fine collection of images of the normal atrial septum and atrial septal defects. •• Pushparajah K, Owen I. Miller OI, Simpson JM. 3D Echocardiography of the atrial septum: anatomical features and landmarks for the echocardiographer. J Am Coll Cardiol Img. 2010;3:981–984. This article includes a fine collection of images of the normal atrial septum and atrial septal defects.
13.
Zurück zum Zitat •• Saric M, Perk G, Purgess JR, Kronzon I. Imaging atrial septal defects by real-time three-dimensional transesophageal echocardiography: step-by-step approach. J Am Soc Echocardiogr 2010;23:1128–35. This report describes a detailed acquisition and imaging protocol for the 3D TEE assessment of ASD.PubMedCrossRef •• Saric M, Perk G, Purgess JR, Kronzon I. Imaging atrial septal defects by real-time three-dimensional transesophageal echocardiography: step-by-step approach. J Am Soc Echocardiogr 2010;23:1128–35. This report describes a detailed acquisition and imaging protocol for the 3D TEE assessment of ASD.PubMedCrossRef
14.
Zurück zum Zitat •• Roberson DA, Cui W, Patel D, et al. Three-Dimensional transesophageal echocardiography of atrial septal defect: a qualitative and quantitative anatomic study J Am Soc Echocardiogr 2011;24:in press. This report provides a complete collection of the anatomic types of ASD as seen by 3D TEE. •• Roberson DA, Cui W, Patel D, et al. Three-Dimensional transesophageal echocardiography of atrial septal defect: a qualitative and quantitative anatomic study J Am Soc Echocardiogr 2011;24:in press. This report provides a complete collection of the anatomic types of ASD as seen by 3D TEE.
15.
Zurück zum Zitat Salustri A, Spitaels S, McGhie J, et al. Transthoracic three-dimensional echocardiography in adult patients with congenital heart disease. J Am Coll Cardiol. 1995;26:759–67.PubMedCrossRef Salustri A, Spitaels S, McGhie J, et al. Transthoracic three-dimensional echocardiography in adult patients with congenital heart disease. J Am Coll Cardiol. 1995;26:759–67.PubMedCrossRef
16.
Zurück zum Zitat Kardon RE, Cao QL, Masani N, et al. New insights and observations in three-dimensional echocardiographic visualization of ventricular septal defects. Circulation. 1998;98:1307–14.PubMed Kardon RE, Cao QL, Masani N, et al. New insights and observations in three-dimensional echocardiographic visualization of ventricular septal defects. Circulation. 1998;98:1307–14.PubMed
17.
Zurück zum Zitat Dall’Agata A, Cromme-Dijkhuis AH, Meijboom FJ, et al. Three-dimensional echocardiography enhances the assessment of ventricular septal defect. Am J Cardiol. 1999;83:1576–9.PubMedCrossRef Dall’Agata A, Cromme-Dijkhuis AH, Meijboom FJ, et al. Three-dimensional echocardiography enhances the assessment of ventricular septal defect. Am J Cardiol. 1999;83:1576–9.PubMedCrossRef
18.
Zurück zum Zitat Acar P, Abdel-Massih T, Douste-Blazy MY, et al. Assessment of muscular ventricular septal defect closure by transcatheter or surgical approach: a three-dimensional echocardiographic study. Eur J Echocardiogr. 2002;3:185–91.PubMedCrossRef Acar P, Abdel-Massih T, Douste-Blazy MY, et al. Assessment of muscular ventricular septal defect closure by transcatheter or surgical approach: a three-dimensional echocardiographic study. Eur J Echocardiogr. 2002;3:185–91.PubMedCrossRef
19.
Zurück zum Zitat Puri T, Liu Z, Doddamani S, et al. Three-dimensional echocardiography of post myocardial infarction cardiac rupture. Echocardiography. 2004;21:279–84.PubMedCrossRef Puri T, Liu Z, Doddamani S, et al. Three-dimensional echocardiography of post myocardial infarction cardiac rupture. Echocardiography. 2004;21:279–84.PubMedCrossRef
20.
Zurück zum Zitat Cheng TO, Xie MX, Wang XF, et al. Real-time 3-dimensional echocardiography in assessing atrial and ventricular septal defects: an echocardiographic-surgical correlative study. Am Heart J. 2004;148:1091–5.PubMedCrossRef Cheng TO, Xie MX, Wang XF, et al. Real-time 3-dimensional echocardiography in assessing atrial and ventricular septal defects: an echocardiographic-surgical correlative study. Am Heart J. 2004;148:1091–5.PubMedCrossRef
21.
Zurück zum Zitat Mehmood F, Miller AP, Nanda NC, et al. Usefulness of live/real time three-dimensional transthoracic echocardiography in the characterization of ventricular septal defects in adults. Echocardiography. 2006;23:421–7.PubMedCrossRef Mehmood F, Miller AP, Nanda NC, et al. Usefulness of live/real time three-dimensional transthoracic echocardiography in the characterization of ventricular septal defects in adults. Echocardiography. 2006;23:421–7.PubMedCrossRef
22.
Zurück zum Zitat Chen FL, Hsiung MC, Nanda N, et al. Real time three-dimensional echocardiography in assessing ventricular septal defects: an echocardiographic-surgical correlative study. Echocardiography. 2006;23:562–8.PubMedCrossRef Chen FL, Hsiung MC, Nanda N, et al. Real time three-dimensional echocardiography in assessing ventricular septal defects: an echocardiographic-surgical correlative study. Echocardiography. 2006;23:562–8.PubMedCrossRef
23.
Zurück zum Zitat Van den Bosch AE, Ten Harkel DJ, McGhie JS, et al. Feasibility and accuracy of real-time 3-dimensional echocardiographic assessment of ventricular septal defects. J Am Soc Echocardiogr. 2006;19:7–13.PubMedCrossRef Van den Bosch AE, Ten Harkel DJ, McGhie JS, et al. Feasibility and accuracy of real-time 3-dimensional echocardiographic assessment of ventricular septal defects. J Am Soc Echocardiogr. 2006;19:7–13.PubMedCrossRef
24.
Zurück zum Zitat Mercer-Rosa L, Seliem MA, Fedec A, et al. Illustration of the additional value of real-time 3-dimensional echocardiography to conventional transthoracic and transesophageal 2-dimensional echocardiography in imaging muscular ventricular septal defects: does this have any impact on individual patient treatment? J Am Soc Echocardiogr. 2006;19:1511–9.PubMedCrossRef Mercer-Rosa L, Seliem MA, Fedec A, et al. Illustration of the additional value of real-time 3-dimensional echocardiography to conventional transthoracic and transesophageal 2-dimensional echocardiography in imaging muscular ventricular septal defects: does this have any impact on individual patient treatment? J Am Soc Echocardiogr. 2006;19:1511–9.PubMedCrossRef
25.
Zurück zum Zitat Seliem MA, Fedec A, Cohen MS, et al. Real-time 3-dimensional echocardiographic imaging of congenital heart disease using matrix-array technology: freehand real-time scanning adds instant morphologic details not well delineated by conventional 2-dimensional imaging. J Am Soc Echocardiogr. 2006;19:121–9.PubMedCrossRef Seliem MA, Fedec A, Cohen MS, et al. Real-time 3-dimensional echocardiographic imaging of congenital heart disease using matrix-array technology: freehand real-time scanning adds instant morphologic details not well delineated by conventional 2-dimensional imaging. J Am Soc Echocardiogr. 2006;19:121–9.PubMedCrossRef
26.
Zurück zum Zitat Hsu JH, Wu JR, Dai ZK, Lee MH. Real-time three-dimensional echocardiography provides novel and useful anatomic insights of perimembranous ventricular septal aneurysm. Int J Cardiol. 2007;118:326–31.PubMedCrossRef Hsu JH, Wu JR, Dai ZK, Lee MH. Real-time three-dimensional echocardiography provides novel and useful anatomic insights of perimembranous ventricular septal aneurysm. Int J Cardiol. 2007;118:326–31.PubMedCrossRef
27.
Zurück zum Zitat Xiong Y, Wah YM, Chen M, et al. Real-time three-dimensional echocardiography using a matrix probe with live X-plane imaging of the interventricular septum. Ultrasound Obstet Gynecol. 2009;34:534–7.PubMedCrossRef Xiong Y, Wah YM, Chen M, et al. Real-time three-dimensional echocardiography using a matrix probe with live X-plane imaging of the interventricular septum. Ultrasound Obstet Gynecol. 2009;34:534–7.PubMedCrossRef
28.
Zurück zum Zitat Ishii M, Hashino K, Eto G, et al. Quantitative assessment of severity of ventricular septal defect by three dimensional reconstruction of color Doppler-imaged vena contracta and flow convergence region. Circulation. 2001;103:664–9.PubMed Ishii M, Hashino K, Eto G, et al. Quantitative assessment of severity of ventricular septal defect by three dimensional reconstruction of color Doppler-imaged vena contracta and flow convergence region. Circulation. 2001;103:664–9.PubMed
29.
Zurück zum Zitat Vasilyev NV, Melnychenko I, Kitahori K, et al. Beating-heart patch closure of muscular ventricular septal defects under real-time three-dimensional echocardiographic guidance: a preclinical study. J Thorac Cardiovasc Surg. 2008;135:603–9.PubMedCrossRef Vasilyev NV, Melnychenko I, Kitahori K, et al. Beating-heart patch closure of muscular ventricular septal defects under real-time three-dimensional echocardiographic guidance: a preclinical study. J Thorac Cardiovasc Surg. 2008;135:603–9.PubMedCrossRef
30.
Zurück zum Zitat Hisagi M, Suematsu Y, Masuzawa A, et al. Image-guided surgical repair of ventricular septal rupture using self-expanding device. Interact Cardiovasc Thorac Surg. 2009;8:602–5.PubMedCrossRef Hisagi M, Suematsu Y, Masuzawa A, et al. Image-guided surgical repair of ventricular septal rupture using self-expanding device. Interact Cardiovasc Thorac Surg. 2009;8:602–5.PubMedCrossRef
Metadaten
Titel
Evaluation of Atrial and Ventricular Septal Defects with Real-Time Three-Dimensional Echocardiography: Current Status and Literature Review
verfasst von
David A. Roberson
Vivian Wei Cui
Publikationsdatum
01.10.2011
Verlag
Current Science Inc.
Erschienen in
Current Cardiovascular Imaging Reports / Ausgabe 5/2011
Print ISSN: 1941-9066
Elektronische ISSN: 1941-9074
DOI
https://doi.org/10.1007/s12410-011-9102-8

Weitere Artikel der Ausgabe 5/2011

Current Cardiovascular Imaging Reports 5/2011 Zur Ausgabe

Nach Herzinfarkt mit Typ-1-Diabetes schlechtere Karten als mit Typ 2?

29.05.2024 Herzinfarkt Nachrichten

Bei Menschen mit Typ-2-Diabetes sind die Chancen, einen Myokardinfarkt zu überleben, in den letzten 15 Jahren deutlich gestiegen – nicht jedoch bei Betroffenen mit Typ 1.

Erhöhtes Risiko fürs Herz unter Checkpointhemmer-Therapie

28.05.2024 Nebenwirkungen der Krebstherapie Nachrichten

Kardiotoxische Nebenwirkungen einer Therapie mit Immuncheckpointhemmern mögen selten sein – wenn sie aber auftreten, wird es für Patienten oft lebensgefährlich. Voruntersuchung und Monitoring sind daher obligat.

GLP-1-Agonisten können Fortschreiten diabetischer Retinopathie begünstigen

24.05.2024 Diabetische Retinopathie Nachrichten

Möglicherweise hängt es von der Art der Diabetesmedikamente ab, wie hoch das Risiko der Betroffenen ist, dass sich sehkraftgefährdende Komplikationen verschlimmern.

TAVI versus Klappenchirurgie: Neue Vergleichsstudie sorgt für Erstaunen

21.05.2024 TAVI Nachrichten

Bei schwerer Aortenstenose und obstruktiver KHK empfehlen die Leitlinien derzeit eine chirurgische Kombi-Behandlung aus Klappenersatz plus Bypass-OP. Diese Empfehlung wird allerdings jetzt durch eine aktuelle Studie infrage gestellt – mit überraschender Deutlichkeit.

Update Kardiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.