Skip to main content
Erschienen in: The International Journal of Cardiovascular Imaging 6/2022

06.01.2022 | Original Paper

High-definition intravascular ultrasound versus optical frequency domain imaging for the detection of calcium modification and fracture in heavily calcified coronary lesion

verfasst von: Masaru Ishida, Yuya Oshikiri, Takumi Kimura, Ryohei Sakamoto, Yudai Shimoda, Yu Ishikawa, Yorihiko Koeda, Yuya Taguchi, Tomonori Itoh, Yoshihiro Morino

Erschienen in: The International Journal of Cardiovascular Imaging | Ausgabe 6/2022

Einloggen, um Zugang zu erhalten

Abstract

While optical frequency domain imaging (OFDI) can delineate calcium modification and fracture, the capability of high-definition intravascular ultrasound (HD-IVUS) for detecting these remains unclear. This study evaluated diagnostic accuracy of HD-IVUS for assessing calcium modification and fracture as compared to OFDI. HD-IVUS and OFDI were used during orbital or rotational atherectomy procedures conducted for 21 heavily calcified coronary lesions in 19 patients. With OFDI assessment used as the gold standard, diagnostic accuracies of HD-IVUS for calcium modification and fracture were compared every 1 mm to the matched pre-stenting images (n = 1129). Calcium modification, as assessed by OFDI, was defined as polished and concave-shaped calcium. For HD-IVUS, calcium modification was defined as the presence of reverberation with concave-shaped calcium. In both assessments, the definition of calcium fracture was defined as a slit or complete break in the calcium plate. Calcified plaque was found in 86.4% of analyzed OFDI images. Calcium modification and fracture were detected in 20.6% and 11.0% of detected calcified plaques. Sensitivity, specificity, positive and negative predictive values of HD-IVUS detection for calcium modification and fracture were 54.4%, 97.8%, 86.7%, 89.1% and 86.0%, 94.5%, 58.2%, 96.8%, respectively. Discordance cases between both assessments demonstrated that heterogeneous calcium visualized by OFDI, separated calcium, and guide wire artifact can be misdiagnosed. Diagnostic accuracies of HD-IVUS for assessing calcium modification and fracture were acceptable as compared to OFDI. Such findings can be of utility during imaging guided interventional procedures with atherectomy.
Literatur
1.
Zurück zum Zitat Huisman J, van der Heijden LC, Kok MM, Louwerenburg JH, Danse PW, Jessurun GA et al (2017) Two-year outcome after treatment of severely calcified lesions with newer-generation drug-eluting stents in acute coronary syndromes: a patient-level pooled analysis from TWENTE and DUTCH PEERS. J Cardiol 69:660–665CrossRef Huisman J, van der Heijden LC, Kok MM, Louwerenburg JH, Danse PW, Jessurun GA et al (2017) Two-year outcome after treatment of severely calcified lesions with newer-generation drug-eluting stents in acute coronary syndromes: a patient-level pooled analysis from TWENTE and DUTCH PEERS. J Cardiol 69:660–665CrossRef
2.
Zurück zum Zitat Guedeney P, Claessen BE, Mehran R, Mintz GS, Liu M, Sorrentino S et al (2020) Coronary calcification and long-term outcomes according to drug-eluting stent generation. JACC Cardiovasc Interv 13:1417–1428CrossRef Guedeney P, Claessen BE, Mehran R, Mintz GS, Liu M, Sorrentino S et al (2020) Coronary calcification and long-term outcomes according to drug-eluting stent generation. JACC Cardiovasc Interv 13:1417–1428CrossRef
3.
Zurück zum Zitat Hoffmann R, Mintz GS, Popma JJ, Satler LF, Kent KM, Pichard AD et al (1998) Treatment of calcified coronary lesions with Palmaz-Schatz stents. An intravascular ultrasound study. Eur Heart J 19:1224–1231CrossRef Hoffmann R, Mintz GS, Popma JJ, Satler LF, Kent KM, Pichard AD et al (1998) Treatment of calcified coronary lesions with Palmaz-Schatz stents. An intravascular ultrasound study. Eur Heart J 19:1224–1231CrossRef
4.
Zurück zum Zitat Fujino A, Mintz GS, Matsumura M, Lee T, Kim SY, Hoshino M et al (2018) A new optical coherence tomography-based calcium scoring system to predict stent underexpansion. EuroIntervention 13:e2182–e2189CrossRef Fujino A, Mintz GS, Matsumura M, Lee T, Kim SY, Hoshino M et al (2018) A new optical coherence tomography-based calcium scoring system to predict stent underexpansion. EuroIntervention 13:e2182–e2189CrossRef
5.
Zurück zum Zitat Fujino A, Mintz GS, Lee T, Hoshino M, Usui E, Kanaji Y et al (2018) Predictors of calcium fracture derived from balloon angioplasty and its effect on stent expansion assessed by optical coherence tomography. JACC Cardiovasc Interv 11:1015–1017CrossRef Fujino A, Mintz GS, Lee T, Hoshino M, Usui E, Kanaji Y et al (2018) Predictors of calcium fracture derived from balloon angioplasty and its effect on stent expansion assessed by optical coherence tomography. JACC Cardiovasc Interv 11:1015–1017CrossRef
6.
Zurück zum Zitat Raber L, Mintz GS, Koskinas KC, Johnson TW, Holm NR, Onuma Y et al (2018) Clinical use of intracoronary imaging. Part 1: guidance and optimization of coronary interventions. An expert consensus document of the European association of percutaneous cardiovascular interventions. Eur Heart J 39:3281–3300CrossRef Raber L, Mintz GS, Koskinas KC, Johnson TW, Holm NR, Onuma Y et al (2018) Clinical use of intracoronary imaging. Part 1: guidance and optimization of coronary interventions. An expert consensus document of the European association of percutaneous cardiovascular interventions. Eur Heart J 39:3281–3300CrossRef
7.
Zurück zum Zitat Sakakura K, Ito Y, Shibata Y, Okamura A, Kashima Y, Nakamura S et al (2021) Clinical expert consensus document on rotational atherectomy from the Japanese association of cardiovascular intervention and therapeutics. Cardiovasc Interv Ther 36:1–18CrossRef Sakakura K, Ito Y, Shibata Y, Okamura A, Kashima Y, Nakamura S et al (2021) Clinical expert consensus document on rotational atherectomy from the Japanese association of cardiovascular intervention and therapeutics. Cardiovasc Interv Ther 36:1–18CrossRef
8.
Zurück zum Zitat Maehara A, Matsumura M, Ali ZA, Mintz GS, Stone GW (2017) IVUS-guided versus OCT-guided coronary stent implantation: a critical appraisal. JACC Cardiovasc Imaging 10:1487–1503CrossRef Maehara A, Matsumura M, Ali ZA, Mintz GS, Stone GW (2017) IVUS-guided versus OCT-guided coronary stent implantation: a critical appraisal. JACC Cardiovasc Imaging 10:1487–1503CrossRef
9.
Zurück zum Zitat Chambers JW, Feldman RL, Himmelstein SI, Bhatheja R, Villa AE, Strickman NE et al (2014) Pivotal trial to evaluate the safety and efficacy of the orbital atherectomy system in treating de novo, severely calcified coronary lesions (ORBIT II). JACC Cardiovasc Interv 7:510–518CrossRef Chambers JW, Feldman RL, Himmelstein SI, Bhatheja R, Villa AE, Strickman NE et al (2014) Pivotal trial to evaluate the safety and efficacy of the orbital atherectomy system in treating de novo, severely calcified coronary lesions (ORBIT II). JACC Cardiovasc Interv 7:510–518CrossRef
10.
Zurück zum Zitat Jang IK, Bouma BE, Kang DH, Park SJ, Park SW, Seung KB et al (2002) Visualization of coronary atherosclerotic plaques in patients using optical coherence tomography: comparison with intravascular ultrasound. J Am Coll Cardiol 39:604–609CrossRef Jang IK, Bouma BE, Kang DH, Park SJ, Park SW, Seung KB et al (2002) Visualization of coronary atherosclerotic plaques in patients using optical coherence tomography: comparison with intravascular ultrasound. J Am Coll Cardiol 39:604–609CrossRef
11.
Zurück zum Zitat Mintz GS, Douek P, Pichard AD, Kent KM, Satler LF, Popma JJ et al (1992) Target lesion calcification in coronary artery disease: an intravascular ultrasound study. J Am Coll Cardiol 20:1149–1155CrossRef Mintz GS, Douek P, Pichard AD, Kent KM, Satler LF, Popma JJ et al (1992) Target lesion calcification in coronary artery disease: an intravascular ultrasound study. J Am Coll Cardiol 20:1149–1155CrossRef
12.
Zurück zum Zitat Lee T, Mintz GS, Matsumura M, Zhang W, Cao Y, Usui E et al (2017) Prevalence, predictors, and clinical presentation of a calcified nodule as assessed by optical coherence tomography. JACC Cardiovasc Imaging 10:883–891CrossRef Lee T, Mintz GS, Matsumura M, Zhang W, Cao Y, Usui E et al (2017) Prevalence, predictors, and clinical presentation of a calcified nodule as assessed by optical coherence tomography. JACC Cardiovasc Imaging 10:883–891CrossRef
13.
Zurück zum Zitat Lee JB, Mintz GS, Lisauskas JB, Biro SG, Pu J, Sum ST et al (2011) Histopathologic validation of the intravascular ultrasound diagnosis of calcified coronary artery nodules. Am J Cardiol 108:1547–1551CrossRef Lee JB, Mintz GS, Lisauskas JB, Biro SG, Pu J, Sum ST et al (2011) Histopathologic validation of the intravascular ultrasound diagnosis of calcified coronary artery nodules. Am J Cardiol 108:1547–1551CrossRef
14.
Zurück zum Zitat Yamamoto MH, Maehara A, Karimi Galougahi K, Mintz GS, Parviz Y, Kim SS et al (2017) Mechanisms of orbital versus rotational atherectomy plaque modification in severely calcified lesions assessed by optical coherence tomography. JACC Cardiovasc Interv 10:2584–2586CrossRef Yamamoto MH, Maehara A, Karimi Galougahi K, Mintz GS, Parviz Y, Kim SS et al (2017) Mechanisms of orbital versus rotational atherectomy plaque modification in severely calcified lesions assessed by optical coherence tomography. JACC Cardiovasc Interv 10:2584–2586CrossRef
15.
Zurück zum Zitat Kim SS, Yamamoto MH, Maehara A, Sidik N, Koyama K, Berry C et al (2018) Intravascular ultrasound assessment of the effects of rotational atherectomy in calcified coronary artery lesions. Int J Cardiovasc Imaging 34:1365–1371CrossRef Kim SS, Yamamoto MH, Maehara A, Sidik N, Koyama K, Berry C et al (2018) Intravascular ultrasound assessment of the effects of rotational atherectomy in calcified coronary artery lesions. Int J Cardiovasc Imaging 34:1365–1371CrossRef
16.
Zurück zum Zitat Ali ZA, Maehara A, Généreux P, Shlofmitz RA, Fabbiocchi F, Nazif TM et al (2016) Optical coherence tomography compared with intravascular ultrasound and with angiography to guide coronary stent implantation (ILUMIEN III: OPTIMIZE PCI): a randomised controlled trial. The Lancet 388:2618–2628CrossRef Ali ZA, Maehara A, Généreux P, Shlofmitz RA, Fabbiocchi F, Nazif TM et al (2016) Optical coherence tomography compared with intravascular ultrasound and with angiography to guide coronary stent implantation (ILUMIEN III: OPTIMIZE PCI): a randomised controlled trial. The Lancet 388:2618–2628CrossRef
17.
Zurück zum Zitat Wang X, Matsumura M, Mintz GS, Lee T, Zhang W, Cao Y et al (2017) In vivo calcium detection by comparing optical coherence tomography, intravascular ultrasound, and angiography. JACC Cardiovasc Imaging 10:869–879CrossRef Wang X, Matsumura M, Mintz GS, Lee T, Zhang W, Cao Y et al (2017) In vivo calcium detection by comparing optical coherence tomography, intravascular ultrasound, and angiography. JACC Cardiovasc Imaging 10:869–879CrossRef
18.
Zurück zum Zitat Pu J, Mintz GS, Biro S, Lee JB, Sum ST, Madden SP et al (2014) Insights into echo-attenuated plaques, echolucent plaques, and plaques with spotty calcification: novel findings from comparisons among intravascular ultrasound, near-infrared spectroscopy, and pathological histology in 2,294 human coronary artery segments. J Am Coll Cardiol 63:2220–2233CrossRef Pu J, Mintz GS, Biro S, Lee JB, Sum ST, Madden SP et al (2014) Insights into echo-attenuated plaques, echolucent plaques, and plaques with spotty calcification: novel findings from comparisons among intravascular ultrasound, near-infrared spectroscopy, and pathological histology in 2,294 human coronary artery segments. J Am Coll Cardiol 63:2220–2233CrossRef
19.
Zurück zum Zitat Ijichi T, Nakazawa G, Torii S, Nakano M, Yoshikawa A, Morino Y et al (2015) Evaluation of coronary arterial calcification—ex-vivo assessment by optical frequency domain imaging. Atherosclerosis 243:242–247CrossRef Ijichi T, Nakazawa G, Torii S, Nakano M, Yoshikawa A, Morino Y et al (2015) Evaluation of coronary arterial calcification—ex-vivo assessment by optical frequency domain imaging. Atherosclerosis 243:242–247CrossRef
20.
Zurück zum Zitat Rieber J, Meissner O, Babaryka G, Reim S, Oswald M, Koenig A et al (2006) Diagnostic accuracy of optical coherence tomography and intravascular ultrasound for the detection and characterization of atherosclerotic plaque composition in ex-vivo coronary specimens: a comparison with histology. Coron Artery Dis 17:425–430CrossRef Rieber J, Meissner O, Babaryka G, Reim S, Oswald M, Koenig A et al (2006) Diagnostic accuracy of optical coherence tomography and intravascular ultrasound for the detection and characterization of atherosclerotic plaque composition in ex-vivo coronary specimens: a comparison with histology. Coron Artery Dis 17:425–430CrossRef
21.
Zurück zum Zitat Kobayashi N, Ito Y, Yamawaki M, Araki M, Obokata M, Sakamoto Y et al (2020) Optical coherence tomography-guided versus intravascular ultrasound-guided rotational atherectomy in patients with calcified coronary lesions. EuroIntervention 16:e313–e321CrossRef Kobayashi N, Ito Y, Yamawaki M, Araki M, Obokata M, Sakamoto Y et al (2020) Optical coherence tomography-guided versus intravascular ultrasound-guided rotational atherectomy in patients with calcified coronary lesions. EuroIntervention 16:e313–e321CrossRef
22.
Zurück zum Zitat Shlofmitz E, Jeremias A, Shlofmitz R, Ali ZA (2019) Lesion preparation with orbital atherectomy. Interv Cardiol 14:169–173CrossRef Shlofmitz E, Jeremias A, Shlofmitz R, Ali ZA (2019) Lesion preparation with orbital atherectomy. Interv Cardiol 14:169–173CrossRef
23.
Zurück zum Zitat Hill JM, Kereiakes DJ, Shlofmitz RA, Klein AJ, Riley RF, Price MJ et al (2020) Intravascular lithotripsy for treatment of severely calcified coronary artery disease. J Am Coll Cardiol 76:2635–2646CrossRef Hill JM, Kereiakes DJ, Shlofmitz RA, Klein AJ, Riley RF, Price MJ et al (2020) Intravascular lithotripsy for treatment of severely calcified coronary artery disease. J Am Coll Cardiol 76:2635–2646CrossRef
24.
Zurück zum Zitat Hong SJ, Kim BK, Shin DH, Nam CM, Kim JS, Ko YG et al (2015) Effect of intravascular ultrasound-guided vs angiography-guided everolimus-eluting stent implantation: the IVUS-XPL randomized clinical trial. JAMA 314:2155–2163CrossRef Hong SJ, Kim BK, Shin DH, Nam CM, Kim JS, Ko YG et al (2015) Effect of intravascular ultrasound-guided vs angiography-guided everolimus-eluting stent implantation: the IVUS-XPL randomized clinical trial. JAMA 314:2155–2163CrossRef
25.
Zurück zum Zitat Zhang J, Gao X, Kan J, Ge Z, Han L, Lu S et al (2018) Intravascular ultrasound versus angiography-guided drug-eluting stent implantation: the ultimate trial. J Am Coll Cardiol 72:3126–3137CrossRef Zhang J, Gao X, Kan J, Ge Z, Han L, Lu S et al (2018) Intravascular ultrasound versus angiography-guided drug-eluting stent implantation: the ultimate trial. J Am Coll Cardiol 72:3126–3137CrossRef
26.
Zurück zum Zitat Elbadawi A, Elzeneini M, Elgendy IY, Mahmoud K, Omer MA, Ogunbayo GO et al (2020) Temporal trends and outcomes of percutaneous coronary atherectomy in the United States. J Invasive Cardiol 32:E110-e121PubMed Elbadawi A, Elzeneini M, Elgendy IY, Mahmoud K, Omer MA, Ogunbayo GO et al (2020) Temporal trends and outcomes of percutaneous coronary atherectomy in the United States. J Invasive Cardiol 32:E110-e121PubMed
27.
Zurück zum Zitat Amemiya K, Yamamoto MH, Maehara A, Oyama Y, Igawa W, Ono M et al (2019) Effect of cutting balloon after rotational atherectomy in severely calcified coronary artery lesions as assessed by optical coherence tomography. Catheter Cardiovasc Interv 94:936–944CrossRef Amemiya K, Yamamoto MH, Maehara A, Oyama Y, Igawa W, Ono M et al (2019) Effect of cutting balloon after rotational atherectomy in severely calcified coronary artery lesions as assessed by optical coherence tomography. Catheter Cardiovasc Interv 94:936–944CrossRef
28.
Zurück zum Zitat Matsukawa R, Kozai T, Tokutome M, Nakashima R, Nishimura R, Matsumoto S et al (2019) Plaque modification using a cutting balloon is more effective for stenting of heavily calcified lesion than other scoring balloons. Cardiovasc Interv Ther 34:325–334CrossRef Matsukawa R, Kozai T, Tokutome M, Nakashima R, Nishimura R, Matsumoto S et al (2019) Plaque modification using a cutting balloon is more effective for stenting of heavily calcified lesion than other scoring balloons. Cardiovasc Interv Ther 34:325–334CrossRef
29.
Zurück zum Zitat Ono M, Kawashima H, Hara H, Gao C, Wang R, Kogame N et al (2020) Advances in IVUS/OCT and future clinical perspective of novel hybrid catheter system in coronary imaging. Front Cardiovasc Med 7:119CrossRef Ono M, Kawashima H, Hara H, Gao C, Wang R, Kogame N et al (2020) Advances in IVUS/OCT and future clinical perspective of novel hybrid catheter system in coronary imaging. Front Cardiovasc Med 7:119CrossRef
Metadaten
Titel
High-definition intravascular ultrasound versus optical frequency domain imaging for the detection of calcium modification and fracture in heavily calcified coronary lesion
verfasst von
Masaru Ishida
Yuya Oshikiri
Takumi Kimura
Ryohei Sakamoto
Yudai Shimoda
Yu Ishikawa
Yorihiko Koeda
Yuya Taguchi
Tomonori Itoh
Yoshihiro Morino
Publikationsdatum
06.01.2022
Verlag
Springer Netherlands
Erschienen in
The International Journal of Cardiovascular Imaging / Ausgabe 6/2022
Print ISSN: 1569-5794
Elektronische ISSN: 1875-8312
DOI
https://doi.org/10.1007/s10554-021-02521-8

Weitere Artikel der Ausgabe 6/2022

The International Journal of Cardiovascular Imaging 6/2022 Zur Ausgabe

„Übersichtlicher Wegweiser“: Lauterbachs umstrittener Klinik-Atlas ist online

17.05.2024 Klinik aktuell Nachrichten

Sie sei „ethisch geboten“, meint Gesundheitsminister Karl Lauterbach: mehr Transparenz über die Qualität von Klinikbehandlungen. Um sie abzubilden, lässt er gegen den Widerstand vieler Länder einen virtuellen Klinik-Atlas freischalten.

„Jeder Fall von plötzlichem Tod muss obduziert werden!“

17.05.2024 Plötzlicher Herztod Nachrichten

Ein signifikanter Anteil der Fälle von plötzlichem Herztod ist genetisch bedingt. Um ihre Verwandten vor diesem Schicksal zu bewahren, sollten jüngere Personen, die plötzlich unerwartet versterben, ausnahmslos einer Autopsie unterzogen werden.

Hirnblutung unter DOAK und VKA ähnlich bedrohlich

17.05.2024 Direkte orale Antikoagulanzien Nachrichten

Kommt es zu einer nichttraumatischen Hirnblutung, spielt es keine große Rolle, ob die Betroffenen zuvor direkt wirksame orale Antikoagulanzien oder Marcumar bekommen haben: Die Prognose ist ähnlich schlecht.

Schlechtere Vorhofflimmern-Prognose bei kleinem linken Ventrikel

17.05.2024 Vorhofflimmern Nachrichten

Nicht nur ein vergrößerter, sondern auch ein kleiner linker Ventrikel ist bei Vorhofflimmern mit einer erhöhten Komplikationsrate assoziiert. Der Zusammenhang besteht nach Daten aus China unabhängig von anderen Risikofaktoren.

Update Kardiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.