Skip to main content
Erschienen in: European Radiology 6/2016

15.09.2015 | Breast

Contrast-enhanced dual energy mammography with a novel anode/filter combination and artifact reduction: a feasibility study

verfasst von: Thomas Knogler, Peter Homolka, Mathias Hörnig, Robert Leithner, Georg Langs, Martin Waitzbauer, Katja Pinker-Domenig, Sabine Leitner, Thomas H. Helbich

Erschienen in: European Radiology | Ausgabe 6/2016

Einloggen, um Zugang zu erhalten

Abstract

Objectives

To demonstrate the feasibility of contrast-enhanced dual-energy mammography (CEDEM) using titanium (Ti) filtering at 49 kVp for high-energy images and a novel artefact reducing image-subtraction post-processing algorithm.

Methods

Fifteen patients with suspicious findings (ACR BI-RADS 4 and 5) detected with digital mammography (MG) that required biopsy were included. CEDEM examinations were performed on a modified prototype machine. Acquired HE and low-energy raw data images were registered non-rigidly to compensate for possible subtle tissue motion. Subtracted CEDEM images were generated via weighted subtraction, using a fully automatic, locally adjusted tissue thickness-dependent subtraction factor to avoid over-subtraction at the breast border. Two observers evaluated the MG and CEDEM images according to ACR BI-RADS in two reading sessions. Results were correlated with histopathology.

Results

Seven patients with benign and eight with malignant findings were included. All malignant lesions showed a strong contrast enhancement. BI-RADS assessment was altered in 66.6 % through the addition of CEDEM, resulting in increased overall accuracy. With CEDEM, additional lesions were depicted and false-positive rate was reduced compared to MG.

Conclusions

CEDEM using Ti filtering with 49 kVp for HE exposures is feasible in a clinical setting. The proposed image-processing algorithm has the potential to reduce artefacts and improve CEDEM images.

Key Points

CEDEM with a titanium filter is feasible in a clinical setting.
Breast thickness-dependent image subtraction has the potential to improve CEDEM images.
The proposed image-processing algorithm reduces artefacts.
Literatur
1.
Zurück zum Zitat Diekmann F, Freyer M, Diekmann S et al (2011) Evaluation of contrast-enhanced digital mammography. Eur J Radiol 78:112–121CrossRefPubMed Diekmann F, Freyer M, Diekmann S et al (2011) Evaluation of contrast-enhanced digital mammography. Eur J Radiol 78:112–121CrossRefPubMed
2.
Zurück zum Zitat Dromain C, Balleyguier C, Adler G, Garbay JR, Delaloge S (2009) Contrast-enhanced digital mammography. Eur J Radiol 69:34–42CrossRefPubMed Dromain C, Balleyguier C, Adler G, Garbay JR, Delaloge S (2009) Contrast-enhanced digital mammography. Eur J Radiol 69:34–42CrossRefPubMed
3.
Zurück zum Zitat Dromain C, Thibault F, Diekmann F et al (2012) Dual-energy contrast-enhanced digital mammography: initial clinical results of a multireader, multicase study. Breast Cancer Res BCR 14:R94CrossRefPubMed Dromain C, Thibault F, Diekmann F et al (2012) Dual-energy contrast-enhanced digital mammography: initial clinical results of a multireader, multicase study. Breast Cancer Res BCR 14:R94CrossRefPubMed
4.
Zurück zum Zitat Jong RA, Yaffe MJ, Skarpathiotakis M et al (2003) Contrast-enhanced digital mammography: initial clinical experience. Radiology 228:842–850CrossRefPubMed Jong RA, Yaffe MJ, Skarpathiotakis M et al (2003) Contrast-enhanced digital mammography: initial clinical experience. Radiology 228:842–850CrossRefPubMed
5.
Zurück zum Zitat Lewin JM, Isaacs PK, Vance V, Larke FJ (2003) Dual-energy contrast-enhanced digital subtraction mammography: feasibility. Radiology 229:261–268CrossRefPubMed Lewin JM, Isaacs PK, Vance V, Larke FJ (2003) Dual-energy contrast-enhanced digital subtraction mammography: feasibility. Radiology 229:261–268CrossRefPubMed
6.
Zurück zum Zitat Jochelson MS, Dershaw DD, Sung JS et al (2013) Bilateral Contrast-enhanced dual-energy digital mammography: Feasibility and comparison with conventional digital mammography and MR imaging in women with known breast carcinoma. Radiology 266:743–751CrossRefPubMed Jochelson MS, Dershaw DD, Sung JS et al (2013) Bilateral Contrast-enhanced dual-energy digital mammography: Feasibility and comparison with conventional digital mammography and MR imaging in women with known breast carcinoma. Radiology 266:743–751CrossRefPubMed
7.
Zurück zum Zitat Diekmann F, Diekmann S, Jeunehomme F, Muller S, Hamm B, Bick U (2005) Digital mammography using iodine-based contrast media: initial clinical experience with dynamic contrast medium enhancement. Invest Radiol 40:397–404CrossRefPubMed Diekmann F, Diekmann S, Jeunehomme F, Muller S, Hamm B, Bick U (2005) Digital mammography using iodine-based contrast media: initial clinical experience with dynamic contrast medium enhancement. Invest Radiol 40:397–404CrossRefPubMed
8.
Zurück zum Zitat Diekmann F, Bick U (2007) Tomosynthesis and contrast-enhanced digital mammography: recent advances in digital mammography. Eur Radiol 17:3086–3092CrossRefPubMed Diekmann F, Bick U (2007) Tomosynthesis and contrast-enhanced digital mammography: recent advances in digital mammography. Eur Radiol 17:3086–3092CrossRefPubMed
9.
Zurück zum Zitat Hörnig MD, Bätz T, Mertelmeier T (2012) Design of a contrast-enhanced dual-energy tomosynthesis system for breast cancer imaging. Proc SPIE 8313, Medical Imaging 2012: Physics of Medical Imaging 8313 Hörnig MD, Bätz T, Mertelmeier T (2012) Design of a contrast-enhanced dual-energy tomosynthesis system for breast cancer imaging. Proc SPIE 8313, Medical Imaging 2012: Physics of Medical Imaging 8313
10.
Zurück zum Zitat Yaffe M (2000) Digital Mammography. In: Beutel J, Kundel HL, Van Metter RL (eds) Handbook of Medical Imaging. SPIE Press, Bellingham Yaffe M (2000) Digital Mammography. In: Beutel J, Kundel HL, Van Metter RL (eds) Handbook of Medical Imaging. SPIE Press, Bellingham
11.
Zurück zum Zitat Bernhardt P, Mertelmeier T, Hoheisel M (2006) X-ray spectrum optimization of full-field digital mammography: simulation and phantom study. Med Phys 33:4337–4349CrossRefPubMed Bernhardt P, Mertelmeier T, Hoheisel M (2006) X-ray spectrum optimization of full-field digital mammography: simulation and phantom study. Med Phys 33:4337–4349CrossRefPubMed
12.
Zurück zum Zitat Samei E, Saunders RS (2011) Dual-energy contrast-enhanced breast tomosynthesis: optimization of beam quality for dose and image quality. Phys Med Biol 56:6359–6378CrossRefPubMedPubMedCentral Samei E, Saunders RS (2011) Dual-energy contrast-enhanced breast tomosynthesis: optimization of beam quality for dose and image quality. Phys Med Biol 56:6359–6378CrossRefPubMedPubMedCentral
13.
Zurück zum Zitat Diekmann F, Sommer A, Lawaczeck R et al (2007) Contrast-to-noise ratios of different elements in digital mammography: evaluation of their potential as new contrast agents. Invest Radiol 42:319–325CrossRefPubMed Diekmann F, Sommer A, Lawaczeck R et al (2007) Contrast-to-noise ratios of different elements in digital mammography: evaluation of their potential as new contrast agents. Invest Radiol 42:319–325CrossRefPubMed
14.
Zurück zum Zitat Carton AK, Gavenonis SC, Currivan JA, Conant EF, Schnall MD, Maidment AD (2010) Dual-energy contrast-enhanced digital breast tomosynthesis—a feasibility study. Br J Radiol 83:344–350CrossRefPubMedPubMedCentral Carton AK, Gavenonis SC, Currivan JA, Conant EF, Schnall MD, Maidment AD (2010) Dual-energy contrast-enhanced digital breast tomosynthesis—a feasibility study. Br J Radiol 83:344–350CrossRefPubMedPubMedCentral
15.
Zurück zum Zitat Helbich TH (2000) Contrast-enhanced magnetic resonance imaging of the breast. Eur J Radiol 34:208–219CrossRefPubMed Helbich TH (2000) Contrast-enhanced magnetic resonance imaging of the breast. Eur J Radiol 34:208–219CrossRefPubMed
16.
Zurück zum Zitat Rosado-Mendez I, Palma BA, Brandan ME (2008) Analytical optimization of digital subtraction mammography with contrast medium using a commercial unit. Med Phys 35:5544–5557CrossRefPubMed Rosado-Mendez I, Palma BA, Brandan ME (2008) Analytical optimization of digital subtraction mammography with contrast medium using a commercial unit. Med Phys 35:5544–5557CrossRefPubMed
17.
Zurück zum Zitat Rueckert D, Sonoda LI, Hayes C, Hill DL, Leach MO, Hawkes DJ (1999) Nonrigid registration using free-form deformations: application to breast MR images. IEEE Trans Med Imaging 18:712–721CrossRefPubMed Rueckert D, Sonoda LI, Hayes C, Hill DL, Leach MO, Hawkes DJ (1999) Nonrigid registration using free-form deformations: application to breast MR images. IEEE Trans Med Imaging 18:712–721CrossRefPubMed
18.
Zurück zum Zitat Carton AK, Ullberg C, Lindman K, Acciavatti R, Francke T, Maidment AD (2010) Optimization of a dual-energy contrast-enhanced technique for a photon-counting digital breast tomosynthesis system: I. A theoretical model. Med Phys 37:5896–5907CrossRefPubMedPubMedCentral Carton AK, Ullberg C, Lindman K, Acciavatti R, Francke T, Maidment AD (2010) Optimization of a dual-energy contrast-enhanced technique for a photon-counting digital breast tomosynthesis system: I. A theoretical model. Med Phys 37:5896–5907CrossRefPubMedPubMedCentral
19.
Zurück zum Zitat Wallis M, Tardivon A, Helbich T, Schreer I, European Society of Breast I (2007) Guidelines from the European Society of Breast Imaging for diagnostic interventional breast procedures. Eur Radiol 17:581–588CrossRefPubMed Wallis M, Tardivon A, Helbich T, Schreer I, European Society of Breast I (2007) Guidelines from the European Society of Breast Imaging for diagnostic interventional breast procedures. Eur Radiol 17:581–588CrossRefPubMed
20.
Zurück zum Zitat Pollard BJ, Samei E, Chawla AS et al (2009) The influence of increased ambient lighting on mass detection in mammograms. Acad Radiol 16:299–304CrossRefPubMed Pollard BJ, Samei E, Chawla AS et al (2009) The influence of increased ambient lighting on mass detection in mammograms. Acad Radiol 16:299–304CrossRefPubMed
21.
Zurück zum Zitat D'Orsi CJ, Sickles EA, Mendelson EB, Morris EA (2013) ACR BI-RADS atlas, breast imaging reporting and data system. American College of Radiology, Reston D'Orsi CJ, Sickles EA, Mendelson EB, Morris EA (2013) ACR BI-RADS atlas, breast imaging reporting and data system. American College of Radiology, Reston
22.
Zurück zum Zitat Skarpathiotakis M, Yaffe MJ, Bloomquist AK et al (2002) Development of contrast digital mammography. Med Phys 29:2419–2426CrossRefPubMed Skarpathiotakis M, Yaffe MJ, Bloomquist AK et al (2002) Development of contrast digital mammography. Med Phys 29:2419–2426CrossRefPubMed
23.
Zurück zum Zitat Leithner R, Knogler T, Homolka P (2013) Development and production of a prototype iodine contrast phantom for CEDEM. Phys Med Biol 58:N25–35CrossRefPubMed Leithner R, Knogler T, Homolka P (2013) Development and production of a prototype iodine contrast phantom for CEDEM. Phys Med Biol 58:N25–35CrossRefPubMed
24.
Zurück zum Zitat Dromain C, Balleyguier C, Muller S et al (2006) Evaluation of tumor angiogenesis of breast carcinoma using contrast-enhanced digital mammography. AJR Am J Roentgenol 187:W528–537CrossRefPubMed Dromain C, Balleyguier C, Muller S et al (2006) Evaluation of tumor angiogenesis of breast carcinoma using contrast-enhanced digital mammography. AJR Am J Roentgenol 187:W528–537CrossRefPubMed
Metadaten
Titel
Contrast-enhanced dual energy mammography with a novel anode/filter combination and artifact reduction: a feasibility study
verfasst von
Thomas Knogler
Peter Homolka
Mathias Hörnig
Robert Leithner
Georg Langs
Martin Waitzbauer
Katja Pinker-Domenig
Sabine Leitner
Thomas H. Helbich
Publikationsdatum
15.09.2015
Verlag
Springer Berlin Heidelberg
Erschienen in
European Radiology / Ausgabe 6/2016
Print ISSN: 0938-7994
Elektronische ISSN: 1432-1084
DOI
https://doi.org/10.1007/s00330-015-4007-6

Weitere Artikel der Ausgabe 6/2016

European Radiology 6/2016 Zur Ausgabe

„Übersichtlicher Wegweiser“: Lauterbachs umstrittener Klinik-Atlas ist online

17.05.2024 Klinik aktuell Nachrichten

Sie sei „ethisch geboten“, meint Gesundheitsminister Karl Lauterbach: mehr Transparenz über die Qualität von Klinikbehandlungen. Um sie abzubilden, lässt er gegen den Widerstand vieler Länder einen virtuellen Klinik-Atlas freischalten.

Klinikreform soll zehntausende Menschenleben retten

15.05.2024 Klinik aktuell Nachrichten

Gesundheitsminister Lauterbach hat die vom Bundeskabinett beschlossene Klinikreform verteidigt. Kritik an den Plänen kommt vom Marburger Bund. Und in den Ländern wird über den Gang zum Vermittlungsausschuss spekuliert.

Darf man die Behandlung eines Neonazis ablehnen?

08.05.2024 Gesellschaft Nachrichten

In einer Leseranfrage in der Zeitschrift Journal of the American Academy of Dermatology möchte ein anonymer Dermatologe bzw. eine anonyme Dermatologin wissen, ob er oder sie einen Patienten behandeln muss, der eine rassistische Tätowierung trägt.

Ein Drittel der jungen Ärztinnen und Ärzte erwägt abzuwandern

07.05.2024 Klinik aktuell Nachrichten

Extreme Arbeitsverdichtung und kaum Supervision: Dr. Andrea Martini, Sprecherin des Bündnisses Junge Ärztinnen und Ärzte (BJÄ) über den Frust des ärztlichen Nachwuchses und die Vorteile des Rucksack-Modells.

Update Radiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.