Skip to main content
Erschienen in: European Radiology 12/2006

Open Access 01.12.2006 | Cardiac

Accuracy of dual-source CT coronary angiography: first experience in a high pre-test probability population without heart rate control

verfasst von: Hans Scheffel, Hatem Alkadhi, André Plass, Robert Vachenauer, Lotus Desbiolles, Oliver Gaemperli, Tiziano Schepis, Thomas Frauenfelder, Thomas Schertler, Lars Husmann, Jürg Grunenfelder, Michele Genoni, Philipp A. Kaufmann, Borut Marincek, Sebastian Leschka

Erschienen in: European Radiology | Ausgabe 12/2006

Abstract

The aim of this study was to assess the diagnostic accuracy of dual-source computed tomography (DSCT) for evaluation of coronary artery disease (CAD) in a population with extensive coronary calcifications without heart rate control. Thirty patients (24 male, 6 female, mean age 63.1±11.3 years) with a high pre-test probability of CAD underwent DSCT coronary angiography and invasive coronary angiography (ICA) within 14±9 days. No beta-blockers were administered prior to the scan. Two readers independently assessed image quality of all coronary segments with a diameter ≥1.5 mm using a four-point score (1: excellent to 4: not assessable) and qualitatively assessed significant stenoses as narrowing of the luminal diameter >50%. Causes of false-positive (FP) and false-negative (FN) ratings were assigned to calcifications or motion artifacts. ICA was considered the standard of reference. Mean body mass index was 28.3±3.9 kg/m2 (range 22.4–36.3 kg/m2), mean heart rate during CT was 70.3±14.2 bpm (range 47–102 bpm), and mean Agatston score was 821±904 (range 0–3,110). Image quality was diagnostic (scores 1–3) in 98.6% (414/420) of segments (mean image quality score 1.68±0.75); six segments in three patients were considered not assessable (1.4%). DSCT correctly identified 54 of 56 significant coronary stenoses. Severe calcifications accounted for false ratings in nine segments (eight FP/one FN) and motion artifacts in two segments (one FP/one FN). Overall sensitivity, specificity, positive and negative predictive value for evaluating CAD were 96.4, 97.5, 85.7, and 99.4%, respectively. First experience indicates that DSCT coronary angiography provides high diagnostic accuracy for assessment of CAD in a high pre-test probability population with extensive coronary calcifications and without heart rate control.

Introduction

Recent advances in multi-detector-row computed tomography (CT) technology have continuously improved the quality of non-invasive coronary artery imaging. As a result, various studies have demonstrated a high accuracy of coronary angiography with 64-slice CT for the diagnosis of coronary artery disease (CAD) [18]. In particular, the high negative predictive value has made non-invasive coronary angiography using 64-slice CT a modality that allows significant coronary stenoses to be reliably excluded. Consequently, the Task Force on the Management of Stable Angina Pectoris of the European Society of Cardiology has recently recommended in their guidelines that CT coronary angiography be performed in patients with stable angina who have a low pre-test probability of CAD, and an inconclusive exercise electrocardiogram (ECG) or stress imaging test [9].
To date, many studies have been published assessing the diagnostic performance of CT coronary angiography with different generations of scanners. Four-slice CT coronary angiography showed limited resolution and required long breath-hold times of nearly 40 s, resulting in a high number of vessel segments that could not be assessed [10]. Sixteen-slice CT coronary angiography showed improved diagnostic accuracy because of reduced breath-hold times and an increased temporal and spatial resolution [11, 12]. Sixty-four-slice CT scanners were the first to allow highly accurate identification of significant coronary artery stenoses [18]. However, data analysis in several of these studies could not be performed in all coronary artery segments, with a percentage of non-assessable segments of up to 12% [2]. The main reasons were severe coronary artery wall calcifications and motion artifacts, the latter occurring especially with higher heart rates. Calcifications are known to complicate the assessment of coronary arteries [10], however, some authors have suggested that substantial coronary calcification should not be used as a reason to defer CT coronary angiography [13].
In order to reduce motion artifacts, the administration of either intravenous or oral beta-blocker medication for heart rate control has been proposed even for 64-slice CT systems [26, 8, 11, 14]. In most studies, target heart rates for scanning were below 60–65 beats per minute (bpm). Another concept to comply with higher coronary velocities at higher heart rates is the use of multi-segment reconstruction algorithms that combine data from two or more consecutive cardiac cycles to improve temporal resolution at certain heart rates [15]. However, the latter approach relies on a complete periodicity of heart motion, limiting its use in patients with variable heart rates; does not take into account the inter-heartbeat variability of coronary artery position; and requires low pitch factors, prolonging data acquisition times [16]. In line with this, a recent 64-slice CT study demonstrated no significant overall benefit of multi-segment reconstruction with regard to image quality of coronary arteries [17].
The recently introduced dual-source CT (DSCT) scanner is characterized by two x-ray tubes and two corresponding detectors mounted onto the rotating gantry with an angular offset of 90° [18]. Regarding cardiac imaging capabilities, the new scanner system offers a high temporal resolution of 83 ms in a mono-segment reconstruction mode. Temporal resolution is independent of the heart rate, which is a major difference from single-source CT systems that rely on multi-segment reconstruction techniques. The first feasibility studies have shown promising results with DSCT coronary angiography regarding image quality of coronary arteries, cardiac valves, and left ventricular myocardium independent of the actual heart rate of the patient [19, 20]. However, to date no study has investigated the diagnostic accuracy of DSCT coronary angiography for the diagnosis of CAD.
The purpose of our study was to determine the performance of DSCT coronary angiography in diagnosing significant stenoses in comparison to invasive coronary angiography (ICA) in a high pre-test probability patient population without heart rate control.

Materials and methods

Patients

In 30 patients (6 women, 24 men; mean age 63.1±11.3 years; age range 35–86 years) who had undergone ICA for evaluation of suspected CAD, CT coronary angiography was performed within 30 days of catheterization (mean 14±9 days). Exclusion criteria for DSCT were allergy to iodine-containing contrast medium, renal insufficiency (creatinine level>120 μmol/L), pregnancy, hemodynamic instability, and previous stent graft placement or bypass surgery. Symptoms and cardiovascular risk factors of all patients are reported in Table 1. Based on a previously published clinical pre-test score [21], each patient in this population had a high pre-test probability of CAD. Patients with elevated or irregular heart rates were not excluded from the study. The study protocol was approved by our local ethics committee and all participating patients gave written informed consent.
Table 1
Synopsis of cardiovascular risk factors and symptoms
 
Frequency (%)
Risk factors
Family history
16 (53%)
Obesity
23 (77%)
Dyslipidemia
18 (60%)
Diabetes
19 (63%)
Smoking
25 (83%)
Hypertension
23 (77%)
Symptoms
Angina pectoris
21 (70%)
Probable angina pectoris
7 (23%)
Atypical chest pain
2 (7%)

Dual-source CT scan protocol

All CT examinations were performed on a DSCT scanner (Somatom Definition, Siemens Medical Solutions, Forchheim, Germany). The patients were centrally placed in the scanner to ensure that the entire heart was covered with the smaller field-of-view of the second tube detector array. Irrespective of the individual heart rate and the heart rate variability, no beta-blockers were given prior to the scan. Three patients took oral beta-blockers as part of their baseline medication.
Nonenhanced DSCT for calcium scoring was performed from 1 cm below the level of the tracheal bifurcation to the diaphragm in a cranio-caudal direction using the following scanning parameters: detector collimation 32×0.6 mm, slice acquisition 64×0.6 mm by means of a z-flying focal spot, gantry rotation time 330 ms, pitch of 0.2–0.39 adapted to the heart rate, tube current 80 mAs per rotation, and tube potential 120 kV.
Thereafter, all patients received a single dose of 2.5 mg isosorbiddinitrate s. l. (Isoket, Schwarz Pharma, Monheim, Germany) [22]. After 2 min, the coronary angiography scan was started by continuously injecting a bolus of 80 ml of iodixanol (Visipaque 320, 320 mg/mL, GE Healthcare, Buckinghamshire, UK) followed by 30 ml saline solution into an antecubital vein via an 18-gauge catheter (injection rate 5 mL/s). Contrast agent application was controlled by bolus tracking. A region of interest (ROI; mean diameter 10.1±5.6 mm, range 7.5–17.0 mm) was placed into the aortic root, and image acquisition started 5 s after the signal attenuation reached the predefined threshold of 100 Hounsfield units (HU). Data acquisition was performed from 1 cm below the level of the tracheal bifurcation to the diaphragm in a cranio-caudal direction with a detector collimation of 32×0.6 mm, slice acquisition 64×0.6 mm by means of a z-flying focal spot, gantry rotation time 330 ms, pitch of 0.2–0.43 adapted to the heart rate, tube current 400 mAs per rotation, and tube potential 120 kV. ECG-pulsing for radiation dose reduction was applied in all patients. At mean heart rates below 60 bpm, full tube current was applied from 60 to 70%, at 61–70 bpm from 50 to 80%, and at heart rates above 70 from 30 to 80% of the RR-interval. The electrocardiogram (ECG) was digitally recorded during data acquisition and was stored with the unprocessed CT dataset.

Dual-source CT image reconstruction

A retrospective gating technique was used to synchronize the data reconstruction with the ECG signal. A mono-segment reconstruction algorithm that uses the data from a quarter rotation of both detectors was used for image reconstruction [18]. In each patient, images were first reconstructed at 60 and 70% of the RR-interval. If considered necessary, additional images were reconstructed in 5% steps of the RR interval within the full tube current window. In case of irregular heart rates, the temporal variability in the reconstruction phase was compensated by manual ECG editing. In case of premature heart beats, the temporal window past the premature heart beat was deleted, and the next diastolic window was filled with one to three temporal windows to avoid data gaps. All ECG editing was performed by one experienced cardiovascular radiologist not involved in data read-out. For calcium scoring, non-overlapping images with a slice width of 3 mm were reconstructed using a medium-sharp convolution kernel (B35f). For DSCT coronary angiography, images were reconstructed from the contrast-enhanced DSCT scan with a slice thickness of 0.75 mm, a reconstruction increment of 0.5 mm, and using a medium soft-tissue convolution kernel (B26f). Depending on the individual anatomy, the reconstructed field-of-view (FoV) was adjusted to encompass the heart exactly (mean FoV 167±19 mm; range 131–187 mm; image matrix 512×512 pixels). After removing patient and ECG information, all reconstructed images were transferred to a dedicated workstation (Wizard, Siemens Medical Solutions) equipped with dedicated cardiac post-processing software (Syngo Circulation, Siemens Medical Solutions).

Dual-source CT data analysis

The mean Agatston score was calculated for each patient from the non-enhanced DSCT data with a detection threshold of 130 HU by using semi-automated software (Syngo Calcium Scoring, Siemens Medical Solutions).
For analysis of DSCT coronary angiography data, coronary arteries were segmented according to the guidelines of the American Heart Association [23]. The right coronary artery (RCA) was defined to include segments 1–4, the left main and left anterior descending artery (LM-LAD) to include segments 5–10, and the left circumflex artery (LCX) to include segments 11–15. The intermedial artery was designated as segment 16, if present. All segments with a diameter of at least 1.5 mm at their origin were included. Diameter measurements were performed with an electronic caliper tool. Segments distal to an occluded vessel were excluded from analysis.
All reconstructed images were evaluated and classified by two independent readers using axial source images, multi-planar reformations (MPR), and thin-slab maximum intensity projections (MIP) on a per-segment basis. Both readers semi-quantitatively assessed the image quality of each coronary segment on a four-point ranking scale as previously published [1]: 1, excellent (no artifacts, unrestricted evaluation); 2, good (minor artifacts, good diagnostic quality); 3, adequate (moderate artifacts, still acceptable and diagnostic), and 4, not assessable (severe artifacts impairing accurate evaluation). Causes of image degradation were noted by both observers as arterial wall calcifications, motion artifacts, or others. Motion artifacts were defined as any impairment of image quality caused by vessel movement resulting in blurred or doubled vessel contours. Other reasons included low vessel opacification, low signal-to-noise ratio, and disturbing adjacent structures such as contrast-enhanced cardiac veins.
In addition, both readers assessed all coronary artery segments for the presence of hemodynamically significant stenoses. Significant stenosis was defined as narrowing of the coronary luminal diameter exceeding 50%. The vessel diameters were measured on reconstructions perpendicularly oriented to the vessel course.
For any disagreement in data analysis, consensus agreement was achieved.

Invasive coronary angiography

ICA was performed according to standard techniques, and multiple views were stored on a CD-ROM. The angiograms were evaluated by one experienced observer who was blinded to the results of the DSCT coronary angiography. Coronary artery segments were defined according to the same guidelines mentioned above [23]. Each vessel segment was scored as being significantly stenosed, defined as a diameter reduction of >50% or not. Coronary artery analysis was performed in all vessels with a luminal diameter of at least 1.5 mm, excluding those vessels distal to complete occlusions.

Statistical analysis

Statistical analysis was performed using commercially available software (SPSS 12.0, SPSS, Chicago, IL, USA). Quantitative variables were expressed as mean±SD and categorical variables as frequencies or percentages. In a subanalysis, patients were subdivided into mean heart rates of <70 bpm and ≥70 bpm and into Agatston scores of <400 and ≥400. We took into account the clustered nature of the data (i.e., the fact that there were not 420 independent vessel segments but instead clusters of segments in 30 patients). Inter-observer agreements for image quality read-out and assessment of significant coronary artery stenoses were interpreted according to the guidelines of Landis and Koch [24] using the clustered data. Sensitivity, specificity, positive predictive value, and negative predictive value were calculated from chi-squared tests of contingency, and the 95% confidence intervals (CI) were calculated from binomial expression on a per-segment basis. Because of the interdependencies between different segments, the statistics were also calculated on a per-patient basis (presence of at least one significant coronary artery stenosis or absence of any significant stenosis in each patient). ICA was considered the standard of reference.

Results

DSCT and ICA were successfully performed in all patients without complications. The DSCT protocol was well tolerated by all patients, and all were able to hold their breath during data acquisition. The average HR during scanning was 70.3±14.2 bpm (range 47–102 bpm). Seventeen patients (56.7%) had a heart rate below 70 bpm (mean 59.7±5.9 bpm, range 47–66 bpm), while 13 patients (43.3%) had a heart rate of ≥70 bpm (mean 84.2±8.4 bpm, range 72–102 bpm).

Prevalance of coronary artery stenosis and calcium score

A total of 56 coronary artery stenoses with a luminal narrowing of more than 50% in diameter were identified in 15 patients (50.0%) using ICA. Single-vessel disease was present in 13.3% (4/30), two-vessel disease in 10.0% (3/30), and three-vessel disease in 26.7% (8/30). Significant coronary artery stenoses could be excluded in 15 patients (50.0%).
Calcified vessel wall deposits were present in 24 patients (80%). Fourteen of these patients (58.3%) had significant coronary artery stenoses, while 10 patients (41.7%) had calcifications without significant stenoses. The mean Agatston score was 821±904 (range 0–3,110). Agatston score was <400 in 15 patients (50%, mean score 85±118) and ≥400 in the other 15 patients (50%, mean score 1,483±893).

Image quality and image reconstruction intervals with DSCT

A total of 420 coronary artery segments with a diameter ≥1.5 mm were evaluated (11 segments were missing because of anatomical variants, 26 segments had a diameter less than 1.5 mm at their origin, and 9 segments were distal to an occluding stenosis). An intermedial artery was present in 16 patients (53.3%). Inter-observer agreement for image quality rating using clustered data was moderate (kappa=0.68). The initially used reconstruction time-points of 60 and 70% provided excellent image quality (score 1) in 21.9% (92/420) and 60.2% (253/420), respectively, while additional reconstructions were necessary in 17.9% (75/420) to improve image quality. Whereas in the subgroup of patients with heart rates ≥70 bpm additional reconstructions at 30 to 50% were considered necessary in 27.4% (48/175), in patients with heart rates <70 bpm, the 60 and 70% interval provided excellent image quality (score 1) in 90.2% of the segments [30.2% (74/245) and 60.0% (147/245), respectively].
Using the individual reconstruction interval with best image quality for each segment, image quality was excellent (score 1) in 47.4% of the coronary segments (199/420), good (score 2) in 37.9% (159/420), adequate (score 3) in 13.3% (56/420), and poor/not assessable in 1.4% (6/420). Non-assessable (score 4) coronary artery segments (segment 4, n=2; segment 8, n=1; segment 10, n=2; and segment 14, n=1) were present in three patients with heart rates of 72, 77, and 86 bpm, and Agatston scores of 30, 616, and 0, respectively.
In the 221 segments with image quality rated other than excellent (score 1), reasons for impaired image quality were arterial wall calcifications in 48.9% (108/221), motion artifacts in 46.6% (103/221), or other in 4.5% of segments (10/221; low signal-to-noise ratio, n=5; low vessel opacification, n=4; overlaying adjacent structures, n=1). At heart rates ≥70 bpm, minor to moderate motion artifacts accounted for 68.2% (73/107) of image quality impairment, while in patients with an Agatston score ≥400, severe arterial wall calcifications were mainly responsible for decreased image quality [76.4% (94/123)].

Diagnostic accuracy of DSCT in comparison to ICA

The kappa value for coronary artery stenosis detection with DSCT was 0.83 indicating a good inter-observer agreement. DSCT coronary angiography correctly recognized 54 of the 56 significant stenoses (96.4%) detected with ICA. For both readers, nine false-positive (FP) and two false-negative (FN) ratings occurred with DSCT coronary angiography. Causes of FP and FN ratings were massive calcifications in nine segments (eight FP, one FN) and motion artifacts in two segments (one FP, one FN). The two FN ratings occurred in segments 8 and 9. Examples of three patients with suspicion of CAD who underwent DSCT coronary angiography are provided in Figs. 1, 2, and 3.
On a per-segment analysis, overall sensitivity was 96.4% (54/56; 95% CI: 87.7–99.6), specificity was 97.5% (355/364; 95% CI: 95.4–98.9), positive predictive value was 85.7% (54/63; 95% CI: 74.6–93.3), and negative predictive value was 99.4% (355/357; 95% CI: 98.0–99.9). Table 2 summarizes demographic data, overall image quality, and diagnostic accuracy of DSCT.
Table 2
Demographic data, overall image quality, and diagnostic accuracy
 
 
Mean heart rate
Agatston score
 
Total
<70 bpm
≥70 bpm
<400
≥400
No. of patients
30
17
13
15
15
Age (years)
63.1±11.3
63.2±10.1
62.9±13.3
62.8±13.7
63.4±8.9
Male/female
24/6
15/2
9/4
10/5
14/1
BMI (kg/m2)
28.3±3.9
28.9±4.3
27.6±3.5
28.1±3.5
28.5±4.4
Mean heart rate (bpm)
70.3±14.2
59.7±5.9
84.2±8.4
70.6±13.7
70.0±15.1
Agatston score
821±904
901±991
674±780
85±118
1,483±893
Overall image qualitya
1.68±0.75
1.60±0.73
1.81±0.77
1.59±0.75
1.79±0.75
 Score 1
47.4% (199/420)
51.8% (131/245)
38.9% (68/175)
54.2% (116/214)
40.3% (83/206)
 Score 2
37.9% (159/420)
32.4% (82/245)
44.0% (77/175)
35.5% (76/214)
40.3% (83/206)
 Score 3
13.3% (56/420)
11.9% (30/245)
14.9% (26/175)
7.5% (16/214)
19.4% (40/206)
 Score 4
1.4% (6/420)
0.8% (2/245)
2.2% (4/175)
2.8% (6/214)
Sensitivity
96.4% (54/56)
97.2% (35/36)
95.0% (19/20)
100% (5/5)
96.1% (49/51)
  95% CI
87.7–99.6
85.5–99.9
75.1–99.9
47.8–100
86.5–99.5
Specificity
97.5% (355/364)
97.1% (203/209)
98.0% (152/155)
99.5% (208/209)
94.8% (147/155)
 95% CI
95.4–98.9
94.2–98.8
94.5–99.6
97.4–100
90.1–97.8
PPV
85.7% (54/63)
85.4% (35/41)
86.4% (19/22)
83.3% (5/6)
86.0% (49/57)
 95% CI
74.6–93.3
70.8–94.4
65.1–97.1
35.9–99.6
74.2–93.7
NPV
99.4% (355/357)
99.5% (203/204)
98.8% (152/153)
100% (208/208)
98.7% (147/149)
 95% CI
98.0–99.9
97.3–100
96.4–100
98.2–100
95.2–99.8
aApplied scores were 1 excellent (no artifacts), 2 good (minor artifacts, good image quality), 3 adequate (moderate artifacts, acceptable image quality), and 4 not assessable (severe artifacts impairing image evaluation). A score of 1–3 was considered acceptable for diagnosis.
BMI Body mass index, CI confidence interval, PPV positive predictive value, NPV negative predictive value
On a per-patient analysis, sensitivity was 93.3% (14/15; 95% CI: 68.1–99.8), specificity was 100% (15/15; 95% CI: 78.2–100), positive predictive value was 100% (14/14; 95% CI: 76.8–100), and negative predictive value was 93.8% (15/16; 95% CI: 69.8–99.8).
In both heart-rate subgroups, diagnostic accuracy for the assessment of coronary artery stenosis was similar and the rate of false ratings was comparable (one FN and six FP at heart rates <70 bpm; one FN and three FP at heart rates ≥70 bpm). In contrast, the subgroup of patients with an Agatston score ≥400 included more false ratings (two FN and eight FP) than the subgroup of patients with an Agatston score <400 (zero FN and one FP). Consequently, sensitivity and specificity were worse in severely calcified vessels (see Table 2).

Discussion

Four main conclusions can be drawn from this study. First, DSCT coronary angiography provides a high diagnostic accuracy for the evaluation of CAD. Second, this high diagnostic performance of DSCT could be achieved in a patient population with extensive calcifications and in whom no heart rate control using beta blocker medication prior to CT was performed. Third, taking into account these circumstances, only six (1.4%) segments had to be excluded from data analysis, all in the distal part of the coronary artery tree with small vessel diameters. Fourth, false ratings were primarily due to severe vessel wall calcifications rather than motion artifacts.
Temporal resolution better than 100 ms in combination with submillimeter isotropic spatial resolution and examination times no longer than 10 s are considered prerequisites for successful implementation of cardiac CT into routine clinical algorithms [18]. DSCT scanners with 0.33-s gantry rotation time and 32×0.6 mm collimation in combination with double z-sampling (i.e., simultaneous acquisition of 64 overlapping 0.6-mm slices) fulfill these requirements.
Early feasibility studies confirmed the technical capacity of DSCT to provide diagnostic image quality of coronary arteries in patients with high heart rates [19, 20]. This study is, to the best of our knowledge, the first to demonstrate a high diagnostic accuracy of DSCT coronary angiography for the diagnosis of CAD in comparison to ICA. By including a patient population with a high prevalence of coronary calcification and without heart rate control during scanning, we found an overall sensitivity of 96.4% and specificity of 97.5% for the detection of significant coronary stenoses. These results are comparable to those previously reported with 64-slice CT; however, beta-blocker administration for strict heart rate control was needed in those studies to compensate for motion artifacts. By including patients with heart rates up to 102 bpm, we found minor to moderate vessel wall blurring due to motion artifacts to be present at high heart rates; however, only 1.4% of all segments had to be excluded from analysis because they were non-diagnostic.
Further confirmation of our preliminary results in larger patient populations may broaden the clinical indications for CT coronary angiography from a modality that is recommended for ruling-out CAD in patients with a low pre-test probability [9] to use in populations with intermediate- or even high pre-test probabilities of the disease. This might also include the implementation of CT coronary angiography as a tool for preoperative planning before cardiac bypass surgery [25] and as a gatekeeper for invasive angiography in patients referred for cardiac valve surgery [26].
Our patient population had a high prevalence of coronary wall calcification, with a mean Agatston score of 821—being higher than the 75% percentile in an age- and gender-matched control population [27]. With 64-slice CT, Raff et al. [2] reported a considerable decline in diagnostic accuracy in patients with Agatston scores >400 with a sensitivity of 93%, a specificity of 67%, and positive and negative predictive values of 93 and 67%, respectively. Using the same cut-off Agatston score, we found a sensitivity of 96%, a specificity of 95%, and positive and negative predictive values of 86 and 99%, respectively. Considering that the spatial resolution of DSCT is the same as that of the single-source 64-slice CT scanner, this apparent difference in calcification-dependency could indicate that the blooming artifact of severely calcified vessel walls may be sometimes superimposed by additional motion artifacts.
We acknowledge the following study limitations. First, we included a relatively small group of only 30 patients. Certainly, future studies with larger patient populations are needed to confirm our first experience. Second, our study patients were a high pre-test probability population, which may have resulted in an overestimation of the ability of DSCT to detect and to rule-out stenoses. In particular the predictive value of positive and negative diagnostic tests is known to be strongly influenced by disease prevalence and pre-test probability. Third, we did not apply the multi-segment reconstruction mode, which possibly may further improve the image quality at elevated heart rates. Fourth, CT coronary angiography is associated with substantial irradiation to the patient. However, using the DSCT system allowed the variable use of ECG-pulsing for dose-saving purposes [28] in all of our patients. In the protocol applied in this study, the ECG-pulsing window width was chosen according to the mean heart rate during scanning, i.e., a relatively narrow window width at low and a larger window width at higher heart rates. As previously performed for 64-slice CT [17, 29], studies analyzing optimum reconstruction intervals for DSCT coronary angiography are mandatory to reduce the width of the pulsing window and the applied radiation dose further. Finally, the ability to use the two x-ray tubes simultaneously with different voltages to improve plaque composition characterization [30] and thus potentially to improve the accuracy of stenosis detection has not been investigated.

Conclusion

First experience indicates that DSCT coronary angiography provides high diagnostic accuracy for assessment of CAD in a high pre-test probability population with extensive coronary calcifications and without heart rate control. Further studies are needed to confirm our results in appropriate clinical settings with larger patient populations.

Acknowledgement

This research has been supported by the National Center of Competence in Research, Computer-Aided and Image-Guided Medical Interventions of the Swiss National Science Foundation.
Open Access This article is licensed under a Creative Commons Attribution-NonCommercial 2.0 International License, which permits any non-commercial use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made.
The images or other third party material in this article are included in the article’s Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder.

Unsere Produktempfehlungen

e.Med Interdisziplinär

Kombi-Abonnement

Für Ihren Erfolg in Klinik und Praxis - Die beste Hilfe in Ihrem Arbeitsalltag

Mit e.Med Interdisziplinär erhalten Sie Zugang zu allen CME-Fortbildungen und Fachzeitschriften auf SpringerMedizin.de.

e.Med Radiologie

Kombi-Abonnement

Mit e.Med Radiologie erhalten Sie Zugang zu CME-Fortbildungen des Fachgebietes Radiologie, den Premium-Inhalten der radiologischen Fachzeitschriften, inklusive einer gedruckten Radiologie-Zeitschrift Ihrer Wahl.

Literatur
1.
Zurück zum Zitat Leschka S et al. (2005) Accuracy of MSCT coronary angiography with 64-slice technology: first experience. Eur Heart J 26:1482–1487PubMedCrossRef Leschka S et al. (2005) Accuracy of MSCT coronary angiography with 64-slice technology: first experience. Eur Heart J 26:1482–1487PubMedCrossRef
2.
Zurück zum Zitat Raff GL, Gallagher MJ, O’Neill WW, Goldstein JA (2005) Diagnostic accuracy of noninvasive coronary angiography using 64-slice spiral computed tomography. J Am Coll Cardiol 46:552–557PubMedCrossRef Raff GL, Gallagher MJ, O’Neill WW, Goldstein JA (2005) Diagnostic accuracy of noninvasive coronary angiography using 64-slice spiral computed tomography. J Am Coll Cardiol 46:552–557PubMedCrossRef
3.
Zurück zum Zitat Leber AW et al. (2005) Quantification of obstructive and nonobstructive coronary lesions by 64-slice computed tomography: a comparative study with quantitative coronary angiography and intravascular ultrasound. J Am Coll Cardiol 46:147–154PubMedCrossRef Leber AW et al. (2005) Quantification of obstructive and nonobstructive coronary lesions by 64-slice computed tomography: a comparative study with quantitative coronary angiography and intravascular ultrasound. J Am Coll Cardiol 46:147–154PubMedCrossRef
4.
Zurück zum Zitat Mollet NR et al. (2005) High-resolution spiral computed tomography coronary angiography in patients referred for diagnostic conventional coronary angiography. Circulation 112:2318–2323PubMedCrossRef Mollet NR et al. (2005) High-resolution spiral computed tomography coronary angiography in patients referred for diagnostic conventional coronary angiography. Circulation 112:2318–2323PubMedCrossRef
5.
Zurück zum Zitat Pugliese F et al. (2006) Diagnostic accuracy of non-invasive 64-slice CT coronary angiography in patients with stable angina pectoris. Eur Radiol 16:575–582CrossRef Pugliese F et al. (2006) Diagnostic accuracy of non-invasive 64-slice CT coronary angiography in patients with stable angina pectoris. Eur Radiol 16:575–582CrossRef
6.
Zurück zum Zitat Nikolaou K et al. (2006) Accuracy of 64-MDCT in the diagnosis of ischemic heart disease. AJR Am J Roentgenol 187:111–117PubMedCrossRef Nikolaou K et al. (2006) Accuracy of 64-MDCT in the diagnosis of ischemic heart disease. AJR Am J Roentgenol 187:111–117PubMedCrossRef
7.
Zurück zum Zitat Ehara M et al. (2006) Diagnostic accuracy of 64-slice computed tomography for detecting angiographically significant coronary artery stenosis in an unselected consecutive patient population: comparison with conventional invasive angiography. Circ J 70:564–571PubMedCrossRef Ehara M et al. (2006) Diagnostic accuracy of 64-slice computed tomography for detecting angiographically significant coronary artery stenosis in an unselected consecutive patient population: comparison with conventional invasive angiography. Circ J 70:564–571PubMedCrossRef
8.
Zurück zum Zitat Ropers D et al. (2006) Usefulness of multidetector row spiral computed tomography with 64- × 0.6-mm collimation and 330-ms rotation for the noninvasive detection of significant coronary artery stenoses. Am J Cardiol 97:343–348PubMedCrossRef Ropers D et al. (2006) Usefulness of multidetector row spiral computed tomography with 64- × 0.6-mm collimation and 330-ms rotation for the noninvasive detection of significant coronary artery stenoses. Am J Cardiol 97:343–348PubMedCrossRef
9.
Zurück zum Zitat Fox K et al. (2006) Guidelines on the management of stable angina pectoris. Executive summary: the Task Force on the Management of Stable Angina Pectoris of the European Society of Cardiology. Eur Heart J 27:1341–1381PubMedCrossRef Fox K et al. (2006) Guidelines on the management of stable angina pectoris. Executive summary: the Task Force on the Management of Stable Angina Pectoris of the European Society of Cardiology. Eur Heart J 27:1341–1381PubMedCrossRef
10.
Zurück zum Zitat Kuettner A et al. (2004) Diagnostic accuracy of multidetector computed tomography coronary angiography in patients with angiographically proven coronary artery disease. J Am Coll Cardiol 43:831–839PubMedCrossRef Kuettner A et al. (2004) Diagnostic accuracy of multidetector computed tomography coronary angiography in patients with angiographically proven coronary artery disease. J Am Coll Cardiol 43:831–839PubMedCrossRef
11.
Zurück zum Zitat Mollet NR et al. (2004) Multislice spiral computed tomography coronary angiography in patients with stable angina pectoris. J Am Coll Cardiol 43:2265–2270PubMedCrossRef Mollet NR et al. (2004) Multislice spiral computed tomography coronary angiography in patients with stable angina pectoris. J Am Coll Cardiol 43:2265–2270PubMedCrossRef
12.
Zurück zum Zitat Kuettner A et al. (2004) Noninvasive detection of coronary lesions using 16-detector multislice spiral computed tomography technology: initial clinical results. J Am Coll Cardiol 44:1230–1237PubMed Kuettner A et al. (2004) Noninvasive detection of coronary lesions using 16-detector multislice spiral computed tomography technology: initial clinical results. J Am Coll Cardiol 44:1230–1237PubMed
13.
Zurück zum Zitat Cademartiri F et al. (2005) Impact of coronary calcium score on diagnostic accuracy for the detection of significant coronary stenosis with multislice computed tomography angiography. Am J Cardiol 95:1225–1227PubMedCrossRef Cademartiri F et al. (2005) Impact of coronary calcium score on diagnostic accuracy for the detection of significant coronary stenosis with multislice computed tomography angiography. Am J Cardiol 95:1225–1227PubMedCrossRef
14.
Zurück zum Zitat Ropers D et al. (2003) Detection of coronary artery stenoses with thin-slice multi-detector row spiral computed tomography and multiplanar reconstruction. Circulation 107:664–666PubMedCrossRef Ropers D et al. (2003) Detection of coronary artery stenoses with thin-slice multi-detector row spiral computed tomography and multiplanar reconstruction. Circulation 107:664–666PubMedCrossRef
15.
Zurück zum Zitat Flohr T, Ohnesorge B (2001) Heart rate adaptive optimization of spatial and temporal resolution for electrocardiogram-gated multislice spiral CT of the heart. J Comput Assist Tomogr 25:907–923PubMedCrossRef Flohr T, Ohnesorge B (2001) Heart rate adaptive optimization of spatial and temporal resolution for electrocardiogram-gated multislice spiral CT of the heart. J Comput Assist Tomogr 25:907–923PubMedCrossRef
16.
Zurück zum Zitat Flohr TG, Schaller S, Stierstorfer K, Bruder H, Ohnesorge BM, Schoepf UJ (2005) Multi-detector row CT systems and image-reconstruction techniques. Radiology 235:756–773PubMed Flohr TG, Schaller S, Stierstorfer K, Bruder H, Ohnesorge BM, Schoepf UJ (2005) Multi-detector row CT systems and image-reconstruction techniques. Radiology 235:756–773PubMed
17.
Zurück zum Zitat Wintersperger BJ et al. (2006) Image quality, motion artifacts, and reconstruction timing of 64-slice coronary computed tomography angiography with 0.33-second rotation speed. Invest Radiol 41:436–442PubMedCrossRef Wintersperger BJ et al. (2006) Image quality, motion artifacts, and reconstruction timing of 64-slice coronary computed tomography angiography with 0.33-second rotation speed. Invest Radiol 41:436–442PubMedCrossRef
18.
Zurück zum Zitat Flohr TG et al. (2006) First performance evaluation of a dual-source CT (DSCT) system. Eur Radiol 16:256–268PubMedCrossRef Flohr TG et al. (2006) First performance evaluation of a dual-source CT (DSCT) system. Eur Radiol 16:256–268PubMedCrossRef
19.
Zurück zum Zitat Achenbach S et al. (2006) Contrast-enhanced coronary artery visualization by dual-source computed tomography-initial experience. Eur J Radiol 57:331–335PubMedCrossRef Achenbach S et al. (2006) Contrast-enhanced coronary artery visualization by dual-source computed tomography-initial experience. Eur J Radiol 57:331–335PubMedCrossRef
20.
Zurück zum Zitat Johnson TR et al. (2006) Dual-source CT cardiac imaging: initial experience. Eur Radiol 16(7):1409–1415PubMedCrossRef Johnson TR et al. (2006) Dual-source CT cardiac imaging: initial experience. Eur Radiol 16(7):1409–1415PubMedCrossRef
21.
Zurück zum Zitat Morise AP, Haddad WJ, Beckner D (1997) Development and validation of a clinical score to estimate the probability of coronary artery disease in men and women presenting with suspected coronary disease. Am J Med 102:350–356PubMedCrossRef Morise AP, Haddad WJ, Beckner D (1997) Development and validation of a clinical score to estimate the probability of coronary artery disease in men and women presenting with suspected coronary disease. Am J Med 102:350–356PubMedCrossRef
22.
Zurück zum Zitat Dewey M, Hoffmann H, Hamm B (2006) Multislice CT coronary angiography: effect of sublingual nitroglycerine on the diameter of coronary arteries. Rofo 178:600–604PubMed Dewey M, Hoffmann H, Hamm B (2006) Multislice CT coronary angiography: effect of sublingual nitroglycerine on the diameter of coronary arteries. Rofo 178:600–604PubMed
23.
Zurück zum Zitat Austen WG et al. (1975) A reporting system on patients evaluated for coronary artery disease. Report of the Ad Hoc Committee for Grading of Coronary Artery Disease, Council on Cardiovascular Surgery, American Heart Association. Circulation 51:5–40PubMed Austen WG et al. (1975) A reporting system on patients evaluated for coronary artery disease. Report of the Ad Hoc Committee for Grading of Coronary Artery Disease, Council on Cardiovascular Surgery, American Heart Association. Circulation 51:5–40PubMed
24.
Zurück zum Zitat Landis JR, Koch GG (1977) The measurement of observer agreement for categorical data. Biometrics 33:159–174PubMedCrossRef Landis JR, Koch GG (1977) The measurement of observer agreement for categorical data. Biometrics 33:159–174PubMedCrossRef
25.
Zurück zum Zitat Plass A et al. (2006) Coronary artery imaging with 64-slice computed tomography from cardiac surgical perspective. Eur J Cardiothorac Surg 30:109–116PubMedCrossRef Plass A et al. (2006) Coronary artery imaging with 64-slice computed tomography from cardiac surgical perspective. Eur J Cardiothorac Surg 30:109–116PubMedCrossRef
26.
Zurück zum Zitat Gilard M et al. (2006) Accuracy of multislice computed tomography in the preoperative assessment of coronary disease in patients with aortic valve stenosis. J Am Coll Cardiol 47:2020–2024PubMedCrossRef Gilard M et al. (2006) Accuracy of multislice computed tomography in the preoperative assessment of coronary disease in patients with aortic valve stenosis. J Am Coll Cardiol 47:2020–2024PubMedCrossRef
27.
Zurück zum Zitat Hoff JA, Chomka EV, Krainik AJ, Daviglus M, Rich S, Kondos GT (2001) Age and gender distributions of coronary artery calcium detected by electron beam tomography in 35,246 adults. Am J Cardiol 87:1335–1339PubMedCrossRef Hoff JA, Chomka EV, Krainik AJ, Daviglus M, Rich S, Kondos GT (2001) Age and gender distributions of coronary artery calcium detected by electron beam tomography in 35,246 adults. Am J Cardiol 87:1335–1339PubMedCrossRef
28.
Zurück zum Zitat Jakobs TF et al. (2002) Multislice helical CT of the heart with retrospective ECG gating: reduction of radiation exposure by ECG-controlled tube current modulation. Eur Radiol 12:1081–1086PubMedCrossRef Jakobs TF et al. (2002) Multislice helical CT of the heart with retrospective ECG gating: reduction of radiation exposure by ECG-controlled tube current modulation. Eur Radiol 12:1081–1086PubMedCrossRef
29.
Zurück zum Zitat Leschka S et al. (2006) Optimal image reconstruction intervals for non-invasive coronary angiography with 64-slice CT. Eur Radiol 16:1964–1972PubMedCrossRef Leschka S et al. (2006) Optimal image reconstruction intervals for non-invasive coronary angiography with 64-slice CT. Eur Radiol 16:1964–1972PubMedCrossRef
30.
Zurück zum Zitat Boll DT, Hoffmann MH, Bossert AS, Aschoff AJ, Fleiter TR (2005) New frontiers in coronary plaque imaging and characterization: polychromatic dual energy multidetector CT with histopathologic correlation. Radiology Suppl:SSD08–09 Boll DT, Hoffmann MH, Bossert AS, Aschoff AJ, Fleiter TR (2005) New frontiers in coronary plaque imaging and characterization: polychromatic dual energy multidetector CT with histopathologic correlation. Radiology Suppl:SSD08–09
Metadaten
Titel
Accuracy of dual-source CT coronary angiography: first experience in a high pre-test probability population without heart rate control
verfasst von
Hans Scheffel
Hatem Alkadhi
André Plass
Robert Vachenauer
Lotus Desbiolles
Oliver Gaemperli
Tiziano Schepis
Thomas Frauenfelder
Thomas Schertler
Lars Husmann
Jürg Grunenfelder
Michele Genoni
Philipp A. Kaufmann
Borut Marincek
Sebastian Leschka
Publikationsdatum
01.12.2006
Verlag
Springer-Verlag
Erschienen in
European Radiology / Ausgabe 12/2006
Print ISSN: 0938-7994
Elektronische ISSN: 1432-1084
DOI
https://doi.org/10.1007/s00330-006-0474-0

Weitere Artikel der Ausgabe 12/2006

European Radiology 12/2006 Zur Ausgabe

Mammakarzinom: Brustdichte beeinflusst rezidivfreies Überleben

26.05.2024 Mammakarzinom Nachrichten

Frauen, die zum Zeitpunkt der Brustkrebsdiagnose eine hohe mammografische Brustdichte aufweisen, haben ein erhöhtes Risiko für ein baldiges Rezidiv, legen neue Daten nahe.

„Übersichtlicher Wegweiser“: Lauterbachs umstrittener Klinik-Atlas ist online

17.05.2024 Klinik aktuell Nachrichten

Sie sei „ethisch geboten“, meint Gesundheitsminister Karl Lauterbach: mehr Transparenz über die Qualität von Klinikbehandlungen. Um sie abzubilden, lässt er gegen den Widerstand vieler Länder einen virtuellen Klinik-Atlas freischalten.

Klinikreform soll zehntausende Menschenleben retten

15.05.2024 Klinik aktuell Nachrichten

Gesundheitsminister Lauterbach hat die vom Bundeskabinett beschlossene Klinikreform verteidigt. Kritik an den Plänen kommt vom Marburger Bund. Und in den Ländern wird über den Gang zum Vermittlungsausschuss spekuliert.

Darf man die Behandlung eines Neonazis ablehnen?

08.05.2024 Gesellschaft Nachrichten

In einer Leseranfrage in der Zeitschrift Journal of the American Academy of Dermatology möchte ein anonymer Dermatologe bzw. eine anonyme Dermatologin wissen, ob er oder sie einen Patienten behandeln muss, der eine rassistische Tätowierung trägt.

Update Radiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.