Abstract

This work proposes a novel secret sharing scheme to enhance the security of Laryngeal Spinocellular Carcinoma or Laryngeal Squamous Cell Carcinoma (LSCC) images using the Discrete Cosine Transformation (DCT) as a cryptographic tool. The DCT-based secret sharing method divides LSCC images into shares, each containing DCT coefficients that represent the image’s frequency components. The original image can only be reconstructed when a predefined number of shares are combined, ensuring confidentiality and preventing unauthorized access. The proposed scheme demonstrates robustness against noise and data loss during transmission, preserving image quality and data integrity. The performance of the proposed scheme concerning the quality of the recovered image and the strength of security preservation is demonstrated through PSNR improvement analysis, correlation analysis, and histogram analysis. The efficiency of DCT-based secret sharing enables application in medical settings, facilitating accurate diagnosis and treatment planning for LSCC patients while safeguarding patient privacy.
Literatur
2.
Zurück zum Zitat Pandey A (2023) Ecg data compression using the formation of qrs-complex segment bank and integer dct-based plateau region processing. Biomed Signal Process Control 85:104823CrossRef Pandey A (2023) Ecg data compression using the formation of qrs-complex segment bank and integer dct-based plateau region processing. Biomed Signal Process Control 85:104823CrossRef
4.
Zurück zum Zitat Hosny S, El-Kharashi MW, Abdel-Hamid AT (2023) Survey on compressed sensing over the past two decades. Mem Mater Device Circuit Syst 4:100060 Hosny S, El-Kharashi MW, Abdel-Hamid AT (2023) Survey on compressed sensing over the past two decades. Mem Mater Device Circuit Syst 4:100060
5.
Zurück zum Zitat Sabry ES, Elagooz SS, Abd El-Samie FE, El-Shafai W, El-Bahnasawy NA, El-Banby GM, Algarni AD, Soliman NF, Ramadan RA (2023) Image retrieval using convolutional autoencoder, infogan, and vision transformer unsupervised models. IEEE Access 11:20445–20477CrossRef Sabry ES, Elagooz SS, Abd El-Samie FE, El-Shafai W, El-Bahnasawy NA, El-Banby GM, Algarni AD, Soliman NF, Ramadan RA (2023) Image retrieval using convolutional autoencoder, infogan, and vision transformer unsupervised models. IEEE Access 11:20445–20477CrossRef
6.
Zurück zum Zitat Phutke SS, Murala S (2021) Channel difference based regeneration architecture for fake colorized image detection. In: International Conference on Computer Vision and Image Processing, pp. 73–84. Springer Phutke SS, Murala S (2021) Channel difference based regeneration architecture for fake colorized image detection. In: International Conference on Computer Vision and Image Processing, pp. 73–84. Springer
7.
Zurück zum Zitat Cong J, Lau J, Liu G, Neuendorffer S, Pan P, Vissers K, Zhang Z (2022) Fpga hls today: successes, challenges, and opportunities. ACM Trans Reconfig Technol Syst (TRETS) 15(4):1–42CrossRef Cong J, Lau J, Liu G, Neuendorffer S, Pan P, Vissers K, Zhang Z (2022) Fpga hls today: successes, challenges, and opportunities. ACM Trans Reconfig Technol Syst (TRETS) 15(4):1–42CrossRef
8.
Zurück zum Zitat Žádník J, Mäkitalo M, Vanne J, Jääskeläinen P (2022) Image and video coding techniques for ultra-low latency. ACM Comput Surv CSUR 54(11s):1–35CrossRef Žádník J, Mäkitalo M, Vanne J, Jääskeläinen P (2022) Image and video coding techniques for ultra-low latency. ACM Comput Surv CSUR 54(11s):1–35CrossRef
9.
Zurück zum Zitat Shrivastava PC, Kumar P, Tiwari M, Dhawan A (2022) An efficient block-based architecture for reconfigurable fir filter using partial-product method. Circuit Syst Signal Process 41(4):2173–2187CrossRef Shrivastava PC, Kumar P, Tiwari M, Dhawan A (2022) An efficient block-based architecture for reconfigurable fir filter using partial-product method. Circuit Syst Signal Process 41(4):2173–2187CrossRef
10.
Zurück zum Zitat Sultana M, Hossain A, Laila F, Taher KA, Islam MN (2020) Towards developing a secure medical image sharing system based on zero trust principles and blockchain technology. BMC Med Inf Decis Mak 20(1):1–10 Sultana M, Hossain A, Laila F, Taher KA, Islam MN (2020) Towards developing a secure medical image sharing system based on zero trust principles and blockchain technology. BMC Med Inf Decis Mak 20(1):1–10
13.
Zurück zum Zitat Sadek MM, Khalifa AS, Mostafa MG (2015) Video steganography: a comprehensive review. Multimed Tool Appl 74:7063–7094CrossRef Sadek MM, Khalifa AS, Mostafa MG (2015) Video steganography: a comprehensive review. Multimed Tool Appl 74:7063–7094CrossRef
15.
Zurück zum Zitat Fan Y, Li J, Bhatti UA, Shao C, Gong C, Cheng J, Chen Y (2023) A multi-watermarking algorithm for medical images using inception v3 and dct. Comput Mater Continua 74(1):1279–1302CrossRef Fan Y, Li J, Bhatti UA, Shao C, Gong C, Cheng J, Chen Y (2023) A multi-watermarking algorithm for medical images using inception v3 and dct. Comput Mater Continua 74(1):1279–1302CrossRef
16.
Zurück zum Zitat Böhme R, Kirchner M (2012) Counter-forensics: Attacking image forensics. In: Digital Image Forensics: There Is More to a Picture Than Meets the Eye, pp. 327–366. Springer Böhme R, Kirchner M (2012) Counter-forensics: Attacking image forensics. In: Digital Image Forensics: There Is More to a Picture Than Meets the Eye, pp. 327–366. Springer
17.
Zurück zum Zitat Ouyang J, Huang J, Wen X, Shao Z (2023) A semi-fragile watermarking tamper localization method based on qdft and multi-view fusion. Multimed Tool Appl 82(10):15113–15141CrossRef Ouyang J, Huang J, Wen X, Shao Z (2023) A semi-fragile watermarking tamper localization method based on qdft and multi-view fusion. Multimed Tool Appl 82(10):15113–15141CrossRef
18.
Zurück zum Zitat Sharma U, Sood M, Puthooran E (2020) A block adaptive near-lossless compression algorithm for medical image sequences and diagnostic quality assessment. J Dig Imag 33(2):516–530CrossRef Sharma U, Sood M, Puthooran E (2020) A block adaptive near-lossless compression algorithm for medical image sequences and diagnostic quality assessment. J Dig Imag 33(2):516–530CrossRef
19.
Zurück zum Zitat Li Z, Ramos A, Li Z, Osborn ML, Zaid W, Li X, Li Y, Xu J (2023) Nearly-lossless-to-lossy medical image compression by the optimized jpegxt and jpeg algorithms through the anatomical regions of interest. Biomed Signal Process Control 83:104711CrossRef Li Z, Ramos A, Li Z, Osborn ML, Zaid W, Li X, Li Y, Xu J (2023) Nearly-lossless-to-lossy medical image compression by the optimized jpegxt and jpeg algorithms through the anatomical regions of interest. Biomed Signal Process Control 83:104711CrossRef
20.
Zurück zum Zitat Hurrah NN, Parah SA, Sheikh JA, Al-Turjman F, Muhammad K (2019) Secure data transmission framework for confidentiality in iots. Ad Hoc Networks 95:101989CrossRef Hurrah NN, Parah SA, Sheikh JA, Al-Turjman F, Muhammad K (2019) Secure data transmission framework for confidentiality in iots. Ad Hoc Networks 95:101989CrossRef
21.
Zurück zum Zitat Ma B, Wang S, Xu J, Wang C, Li J, Li X (2023) A multi-level sorting prediction enhancement-based two-dimensional reversible data hiding algorithm for jpeg images. Digital Signal Process 141:104145CrossRef Ma B, Wang S, Xu J, Wang C, Li J, Li X (2023) A multi-level sorting prediction enhancement-based two-dimensional reversible data hiding algorithm for jpeg images. Digital Signal Process 141:104145CrossRef
22.
Zurück zum Zitat Hou Y-C, Lin C, Chang C-Y (2001) Visual cryptography for color images without pixel expansion. J Technol 16(4):595–603 Hou Y-C, Lin C, Chang C-Y (2001) Visual cryptography for color images without pixel expansion. J Technol 16(4):595–603
23.
Zurück zum Zitat Maurya S, Nandu N, Patel T, Reddy VD, Tiwari S, Morampudi MK (2023) A discrete cosine transform-based intelligent image steganography scheme using quantum substitution box. Quant Inf Process 22(5):206ADSMathSciNetCrossRef Maurya S, Nandu N, Patel T, Reddy VD, Tiwari S, Morampudi MK (2023) A discrete cosine transform-based intelligent image steganography scheme using quantum substitution box. Quant Inf Process 22(5):206ADSMathSciNetCrossRef
24.
Zurück zum Zitat Moccia S, De Momi E, Guarnaschelli M, Savazzi M, Laborai A, Guastini L, Peretti G, Mattos LS (2017) Confident texture-based laryngeal tissue classification for early stage diagnosis support. J Med Imag 4(3):034502–034502CrossRef Moccia S, De Momi E, Guarnaschelli M, Savazzi M, Laborai A, Guastini L, Peretti G, Mattos LS (2017) Confident texture-based laryngeal tissue classification for early stage diagnosis support. J Med Imag 4(3):034502–034502CrossRef
Metadaten
Titel
Enhancing Laryngeal Spinocellular Carcinoma Image Security with DCT
verfasst von
Raviraja Holla
D. Suma
Publikationsdatum
11.10.2023
Verlag
Springer India
Erschienen in
Indian Journal of Otolaryngology and Head & Neck Surgery / Ausgabe 1/2024
Print ISSN: 2231-3796
Elektronische ISSN: 0973-7707
DOI
https://doi.org/10.1007/s12070-023-04255-6

Weitere Artikel der Ausgabe 1/2024

Indian Journal of Otolaryngology and Head & Neck Surgery 1/2024 Zur Ausgabe

Erhebliches Risiko für Kehlkopfkrebs bei mäßiger Dysplasie

29.05.2024 Larynxkarzinom Nachrichten

Fast ein Viertel der Personen mit mäßig dysplastischen Stimmlippenläsionen entwickelt einen Kehlkopftumor. Solche Personen benötigen daher eine besonders enge ärztliche Überwachung.

Hörschwäche erhöht Demenzrisiko unabhängig von Beta-Amyloid

29.05.2024 Hörstörungen Nachrichten

Hört jemand im Alter schlecht, nimmt das Hirn- und Hippocampusvolumen besonders schnell ab, was auch mit einem beschleunigten kognitiven Abbau einhergeht. Und diese Prozesse scheinen sich unabhängig von der Amyloidablagerung zu ereignen.

„Übersichtlicher Wegweiser“: Lauterbachs umstrittener Klinik-Atlas ist online

17.05.2024 Klinik aktuell Nachrichten

Sie sei „ethisch geboten“, meint Gesundheitsminister Karl Lauterbach: mehr Transparenz über die Qualität von Klinikbehandlungen. Um sie abzubilden, lässt er gegen den Widerstand vieler Länder einen virtuellen Klinik-Atlas freischalten.

Betalaktam-Allergie: praxisnahes Vorgehen beim Delabeling

16.05.2024 Pädiatrische Allergologie Nachrichten

Die große Mehrheit der vermeintlichen Penicillinallergien sind keine. Da das „Etikett“ Betalaktam-Allergie oft schon in der Kindheit erworben wird, kann ein frühzeitiges Delabeling lebenslange Vorteile bringen. Ein Team von Pädiaterinnen und Pädiatern aus Kanada stellt vor, wie sie dabei vorgehen.

Update HNO

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert – ganz bequem per eMail.