Skip to main content

10.05.2024 | Original Article

Diagnostic efficacy of [68Ga]Ga-DOTA-GPFAPI-04 in patients with solid tumors in a head-to-head comparison with [18F]F-FDG: results from a prospective clinical study

verfasst von: Hui Yuan, Entao Liu, Guojin Zhang, Chaoquan Lai, Qing Zhang, Yuxiang Shang, Zhen Cheng, Lei Jiang

Erschienen in: European Journal of Nuclear Medicine and Molecular Imaging

Einloggen, um Zugang zu erhalten

Abstract

Purpose

To identify the biodistribution and diagnostic performance of a novel fibroblast activation protein (FAP) targeted positron emission tomography (PET) tracer, [68Ga]Ga-DOTA-GPFAPI-04, in patients with solid tumors in a head-to-head comparison with [18F]F-FDG.

Methods

Twenty-six patients histologically proven with cancers of nasopharyngeal (n = 5), esophagus (n = 5), gastro-esophagus (n = 1), stomach (n = 7), liver (n = 3), and colorectum (n = 5) were recruited for [68Ga]Ga-DOTA-GPFAPI-04 and [18F]F-FDG PET/CT scans on consecutive days. The primary endpoint was the diagnostic efficacy, with the histological diagnosis and the follow-up results selected as the gold standard. The secondary endpoint was the background uptake pattern. Two experienced nuclear medicine physicians who were blinded to the gold standard results while having essential awareness of the clinical context reviewed the images and labeled lesions by consensus for subsequent software-assisted lesion segmentation. Additionally, background organs were automatically segmented, assisted by artificial intelligence. Volume, mean, and maximum standard uptake values (SUVmean and SUVmax) of all segmentations were recorded. P < 0.05 was deemed as statistically significant.

Results

Significant glandular uptake of [68Ga]Ga-DOTA-GPFAPI-04 was detected in the thyroid, pancreas, and submandibular glands, while moderate uptake was observed in the parotid glands. The myocardium and myometrium exhibited 2–3 times higher uptake of the radiotracer than that of the background levels in blood and liver. A total of 349 targeted lesions, consisting of 324 malignancies and 25 benign lesions, were segmented. [68Ga]Ga-DOTA-GPFAPI-04 is more sensitive than [18F]F-FDG, especially for abdominopelvic dissemination (1.000 vs. 0.475, P < 0.001). Interestingly, [18F]F-FDG demonstrated higher sensitivity for lung metastasis compared to [68Ga]Ga-DOTA-GPFAPI-04 (0.845 vs. 0.682, P = 0.003). The high glandular uptake made it difficult to delineate lesions in close proximity and masked two metastatic lesions in these organs.

Conclusion

Despite prominent glandular uptake, [68Ga]Ga-DOTA-GPFAPI-04 demonstrates favorable diagnostic performance. It is a promising probe scaffold for further development of FAP-targeted tumor theranostic agents.
Anhänge
Nur mit Berechtigung zugänglich
Literatur
Metadaten
Titel
Diagnostic efficacy of [68Ga]Ga-DOTA-GPFAPI-04 in patients with solid tumors in a head-to-head comparison with [18F]F-FDG: results from a prospective clinical study
verfasst von
Hui Yuan
Entao Liu
Guojin Zhang
Chaoquan Lai
Qing Zhang
Yuxiang Shang
Zhen Cheng
Lei Jiang
Publikationsdatum
10.05.2024
Verlag
Springer Berlin Heidelberg
Erschienen in
European Journal of Nuclear Medicine and Molecular Imaging
Print ISSN: 1619-7070
Elektronische ISSN: 1619-7089
DOI
https://doi.org/10.1007/s00259-024-06756-0