Abstract

This study investigates the feasibility of imaging the coronary lumen and vessel-wall, using MRI with a radial k-space trajectory at 3 T. Such radial trajectories offer the advantage of greater vessel sharpness than traditional Cartesian trajectories. This field strength offers an increased signal-to-noise ratio (SNR) compared with 1.5 T, which compensates for the slight SNR reduction due to the radial sequence. Images of the coronary lumen were acquired for seven healthy volunteers. In ten volunteers the vessel wall was scanned, with blood suppression using oblique-slab adiabatic re-inversion. Scans were performed during free breathing, using prospective respiratory navigator-gating. Coronary lumen scans had SNR of 16.0±1.9 and contrast-to-noise ratio (CNR) of 10.3±2.1, showing acceptable image quality. Vessel wall images showed good image quality, with mean SNR of 16.6±2.0/5.8±2.8/10.1±2.2 for vessel wall/lumen/epicardial fat. The wall-blood CNR was 10.7±2.7, and wall-fat CNR was 6.5±2.5. It is concluded that radial gradient-echo imaging at 3 T is a promising method for coronary vessel-wall imaging, and is also feasible for imaging the coronary lumen.
Literatur
2.
Zurück zum Zitat Liu YL, Riederer SJ, Rossman PJ, Grimm RC, Debbins JP, Ehman RL (1993) A monitoring, feedback, and triggering system for reproducible breath-hold MR imaging. Magn Reson Med 30:507–511PubMedCrossRef Liu YL, Riederer SJ, Rossman PJ, Grimm RC, Debbins JP, Ehman RL (1993) A monitoring, feedback, and triggering system for reproducible breath-hold MR imaging. Magn Reson Med 30:507–511PubMedCrossRef
3.
Zurück zum Zitat Wang Y, Rossman PJ, Grimm RC, Riederer SJ, Ehman RL (1996) Navigator-echo-based real-time respiratory gating and triggering for reduction of respiration effects in three-dimensional coronary MR angiography. Radiology 198:55–60PubMed Wang Y, Rossman PJ, Grimm RC, Riederer SJ, Ehman RL (1996) Navigator-echo-based real-time respiratory gating and triggering for reduction of respiration effects in three-dimensional coronary MR angiography. Radiology 198:55–60PubMed
4.
Zurück zum Zitat McConnell MV, Khasgiwala VC, Savord BJ, Chen MH, Chuang ML, Edelman RR, Manning WJ (1997) Prospective adaptive navigator correction for breath-hold MR coronary angiography. Magn Reson Med 37:148–152PubMedCrossRef McConnell MV, Khasgiwala VC, Savord BJ, Chen MH, Chuang ML, Edelman RR, Manning WJ (1997) Prospective adaptive navigator correction for breath-hold MR coronary angiography. Magn Reson Med 37:148–152PubMedCrossRef
6.
Zurück zum Zitat Kim WY, Danias PG, Stuber M, Flamm SD, Plein S, Nagel E, Langerak SE, Weber OM, Pedersen EM, Schmidt M, Botnar RM, Manning WJ (2001) Coronary magnetic resonance angiography for the detection of coronary stenoses. N Engl J Med 345:1863–1869CrossRef Kim WY, Danias PG, Stuber M, Flamm SD, Plein S, Nagel E, Langerak SE, Weber OM, Pedersen EM, Schmidt M, Botnar RM, Manning WJ (2001) Coronary magnetic resonance angiography for the detection of coronary stenoses. N Engl J Med 345:1863–1869CrossRef
7.
Zurück zum Zitat Edelman RR, Chien D, Kim D (1991) Fast selective black blood MR imaging. Radiology 181:655–660PubMed Edelman RR, Chien D, Kim D (1991) Fast selective black blood MR imaging. Radiology 181:655–660PubMed
8.
Zurück zum Zitat Fayad ZA, Fuster V, Fallon JT, Jayasundera T, Worthley SG, Helft G, Aguinaldo JG, Badimon JJ, Sharma SK (2000) Noninvasive in vivo human coronary artery lumen and wall imaging using black-blood magnetic resonance imaging. Circulation 102:506–510PubMed Fayad ZA, Fuster V, Fallon JT, Jayasundera T, Worthley SG, Helft G, Aguinaldo JG, Badimon JJ, Sharma SK (2000) Noninvasive in vivo human coronary artery lumen and wall imaging using black-blood magnetic resonance imaging. Circulation 102:506–510PubMed
9.
Zurück zum Zitat Botnar RM, Stuber M, Kissinger KV, Kim WY, Spuentrup E, Manning WJ (2000) Noninvasive coronary vessel wall and plaque imaging with magnetic resonance imaging. Circulation 102:2582–2587PubMed Botnar RM, Stuber M, Kissinger KV, Kim WY, Spuentrup E, Manning WJ (2000) Noninvasive coronary vessel wall and plaque imaging with magnetic resonance imaging. Circulation 102:2582–2587PubMed
10.
Zurück zum Zitat Botnar RM, Kim WY, Bornert P, Stuber M, Spuentrup E, Manning WJ (2001) 3D coronary vessel wall imaging utilizing a local inversion technique with spiral image acquisition. Magn Reson Med 46:848–854. DOI 10.1002/mrm.1268 PubMedCrossRef Botnar RM, Kim WY, Bornert P, Stuber M, Spuentrup E, Manning WJ (2001) 3D coronary vessel wall imaging utilizing a local inversion technique with spiral image acquisition. Magn Reson Med 46:848–854. DOI 10.​1002/​mrm.​1268 PubMedCrossRef
12.
Zurück zum Zitat Kim WY, Stuber M, Bornert P, Kissinger KV, Manning WJ, Botnar RM (2002) Three-dimensional black-blood cardiac magnetic resonance coronary vessel wall imaging detects positive arterial remodeling in patients with nonsignificant coronary artery disease. Circulation 106:296–299. DOI 10.1161/01.CIR.0000025629.85631.1E PubMedCrossRef Kim WY, Stuber M, Bornert P, Kissinger KV, Manning WJ, Botnar RM (2002) Three-dimensional black-blood cardiac magnetic resonance coronary vessel wall imaging detects positive arterial remodeling in patients with nonsignificant coronary artery disease. Circulation 106:296–299. DOI 10.​1161/​01.​CIR.​0000025629.​85631.​1E PubMedCrossRef
13.
Zurück zum Zitat Little WC, Constantinescu M, Applegate RJ, Kutcher MA, Burrows MT, Kahl FR, Santamore WP (1988) Can coronary angiography predict the site of a subsequent myocardial infarction in patients with mild-to-moderate coronary artery disease? Circulation 78(5 Pt 1):1157–1166PubMed Little WC, Constantinescu M, Applegate RJ, Kutcher MA, Burrows MT, Kahl FR, Santamore WP (1988) Can coronary angiography predict the site of a subsequent myocardial infarction in patients with mild-to-moderate coronary artery disease? Circulation 78(5 Pt 1):1157–1166PubMed
14.
Zurück zum Zitat Spuentrup E, Katoh M, Stuber M, Botnar R, Schaeffter T, Buecker A, Gunther RW (2003) Coronary MR imaging using free-breathing 3D steady-state free precession with radial k-space sampling. Rofo 175:1330–1334. DOI 10.1055/s-2003-42895 PubMed Spuentrup E, Katoh M, Stuber M, Botnar R, Schaeffter T, Buecker A, Gunther RW (2003) Coronary MR imaging using free-breathing 3D steady-state free precession with radial k-space sampling. Rofo 175:1330–1334. DOI 10.​1055/​s-2003-42895 PubMed
15.
Zurück zum Zitat Spuentrup E, Katoh M, Buecker A, Manning WJ, Schaeffter T, Nguyen TH, Kuhl HP, Stuber M, Botnar RM, Gunther RW (2004) Free-breathing 3D steady-state free precession coronary MR angiography with radial k-space sampling: comparison with cartesian k-space sampling and cartesian gradient-echo coronary MR angiography-pilot study. Radiology 231:581–586. DOI 10.1148/radiol.2312030451 PubMedCrossRef Spuentrup E, Katoh M, Buecker A, Manning WJ, Schaeffter T, Nguyen TH, Kuhl HP, Stuber M, Botnar RM, Gunther RW (2004) Free-breathing 3D steady-state free precession coronary MR angiography with radial k-space sampling: comparison with cartesian k-space sampling and cartesian gradient-echo coronary MR angiography-pilot study. Radiology 231:581–586. DOI 10.​1148/​radiol.​2312030451 PubMedCrossRef
16.
Zurück zum Zitat Weber OM, Pujadas S, Martin AJ, Higgins CB (2004) Free-breathing, three-dimensional coronary artery magnetic resonance angiography: comparison of sequences. J Magn Reson Imaging 20:395–402. DOI 10.1002/jmri.20141 PubMedCrossRef Weber OM, Pujadas S, Martin AJ, Higgins CB (2004) Free-breathing, three-dimensional coronary artery magnetic resonance angiography: comparison of sequences. J Magn Reson Imaging 20:395–402. DOI 10.​1002/​jmri.​20141 PubMedCrossRef
17.
Zurück zum Zitat Katoh M, Spuentrup E, Buecker A, Manning WJ, Gunther RW, Botnar RM (2006) MR coronary vessel wall imaging: comparison between radial and spiral k-space sampling. J Magn Reson Imaging 23:757–762. DOI 10.1002/jmri.20569 PubMedCrossRef Katoh M, Spuentrup E, Buecker A, Manning WJ, Gunther RW, Botnar RM (2006) MR coronary vessel wall imaging: comparison between radial and spiral k-space sampling. J Magn Reson Imaging 23:757–762. DOI 10.​1002/​jmri.​20569 PubMedCrossRef
18.
19.
Zurück zum Zitat Stuber M, Botnar RM, Fischer SE, Lamerichs R, Smink J, Harvey P, Manning WJ (2002) Preliminary report on in vivo coronary MRA at 3 Tesla in humans. Magn Reson Med 48:425–429. DOI 10.1002/mrm.10240 PubMedCrossRef Stuber M, Botnar RM, Fischer SE, Lamerichs R, Smink J, Harvey P, Manning WJ (2002) Preliminary report on in vivo coronary MRA at 3 Tesla in humans. Magn Reson Med 48:425–429. DOI 10.​1002/​mrm.​10240 PubMedCrossRef
21.
Zurück zum Zitat Kaul MG, Stork A, Bansmann PM, Nolte-Ernsting C, Lund GK, Weber C, Adam G (2004) Evaluation of balanced steady-state free precession (TrueFISP) and k-space segmented gradient echo sequences for 3D coronary MR angiography with navigator gating at 3 Tesla. Rofo 176:1560–1565. DOI 10.1055/s-2004-813629 PubMed Kaul MG, Stork A, Bansmann PM, Nolte-Ernsting C, Lund GK, Weber C, Adam G (2004) Evaluation of balanced steady-state free precession (TrueFISP) and k-space segmented gradient echo sequences for 3D coronary MR angiography with navigator gating at 3 Tesla. Rofo 176:1560–1565. DOI 10.​1055/​s-2004-813629 PubMed
22.
Zurück zum Zitat Bi X, Deshpande V, Simonetti O, Laub G, Li D (2005) Three-dimensional breathhold SSFP coronary MRA: a comparison between 1.5 T and 3.0 T. J Magn Reson Imaging 22:206–212. DOI 10.1002/jmri.20374 PubMedCrossRef Bi X, Deshpande V, Simonetti O, Laub G, Li D (2005) Three-dimensional breathhold SSFP coronary MRA: a comparison between 1.5 T and 3.0 T. J Magn Reson Imaging 22:206–212. DOI 10.​1002/​jmri.​20374 PubMedCrossRef
23.
Zurück zum Zitat Sommer T, Hackenbroch M, Hofer U, Schmiedel A, Willinek WA, Flacke S, Gieseke J, Traber F, Fimmers R, Litt H, Schild H (2005) Coronary MR angiography at 3.0 T versus that at 1.5 T: initial results in patients suspected of having coronary artery disease. Radiology 234:718–725. DOI 10.1148/radiol.2343031784 PubMedCrossRef Sommer T, Hackenbroch M, Hofer U, Schmiedel A, Willinek WA, Flacke S, Gieseke J, Traber F, Fimmers R, Litt H, Schild H (2005) Coronary MR angiography at 3.0 T versus that at 1.5 T: initial results in patients suspected of having coronary artery disease. Radiology 234:718–725. DOI 10.​1148/​radiol.​2343031784 PubMedCrossRef
24.
Zurück zum Zitat Botnar RM, Stuber M, Lamerichs R, Smink J, Fischer SE, Harvey P, Manning WJ (2003) Initial experiences with in vivo right coronary artery human MR vessel wall imaging at 3 Tesla. J Cardiovasc Magn Reson 5:589–594. DOI 10.1081/JCMR-120025232 PubMedCrossRef Botnar RM, Stuber M, Lamerichs R, Smink J, Fischer SE, Harvey P, Manning WJ (2003) Initial experiences with in vivo right coronary artery human MR vessel wall imaging at 3 Tesla. J Cardiovasc Magn Reson 5:589–594. DOI 10.​1081/​JCMR-120025232 PubMedCrossRef
26.
Zurück zum Zitat Priest AN, Bansmann PM, Kaul MG, Stork A, Adam G (2005) Magnetic resonance imaging of the coronary vessel wall at 3 T using an obliquely oriented reinversion slab with adiabatic pulses. Magn Reson Med 54:1115–1122. DOI 10.1002/mrm.20681 PubMedCrossRef Priest AN, Bansmann PM, Kaul MG, Stork A, Adam G (2005) Magnetic resonance imaging of the coronary vessel wall at 3 T using an obliquely oriented reinversion slab with adiabatic pulses. Magn Reson Med 54:1115–1122. DOI 10.​1002/​mrm.​20681 PubMedCrossRef
27.
Zurück zum Zitat Greenman RL, Shirosky JE, Mulkern RV, Rofsky NM (2003) Double inversion black-blood fast spin-echo imaging of the human heart: a comparison between 1.5 T and 3.0 T. J Magn Reson Imaging 17:648–655. DOI 10.1002/jmri.10316 PubMedCrossRef Greenman RL, Shirosky JE, Mulkern RV, Rofsky NM (2003) Double inversion black-blood fast spin-echo imaging of the human heart: a comparison between 1.5 T and 3.0 T. J Magn Reson Imaging 17:648–655. DOI 10.​1002/​jmri.​10316 PubMedCrossRef
29.
Zurück zum Zitat Fischer SE, Wickline SA, Lorenz CH (1999) Novel real-time R-wave detection algorithm based on the vectorcardiogram for accurate gated magnetic resonance acquisitions. Magn Reson Med 42:361–370PubMedCrossRef Fischer SE, Wickline SA, Lorenz CH (1999) Novel real-time R-wave detection algorithm based on the vectorcardiogram for accurate gated magnetic resonance acquisitions. Magn Reson Med 42:361–370PubMedCrossRef
30.
Zurück zum Zitat Kim WY, Stuber M, Kissinger KV, Andersen NT, Manning WJ, Botnar RM (2001) Impact of bulk cardiac motion on right coronary MR angiography and vessel wall imaging. J Magn Reson Imaging 14:383–390. DOI 10.1002/jmri.1198 PubMedCrossRef Kim WY, Stuber M, Kissinger KV, Andersen NT, Manning WJ, Botnar RM (2001) Impact of bulk cardiac motion on right coronary MR angiography and vessel wall imaging. J Magn Reson Imaging 14:383–390. DOI 10.​1002/​jmri.​1198 PubMedCrossRef
31.
Zurück zum Zitat Brittain JH, Hu BS, Wright GA, Meyer CH, Macovski A, Nishimura DG (1995) Coronary angiography with magnetization-prepared T2 contrast. Magn Reson Med 33:689–696PubMedCrossRef Brittain JH, Hu BS, Wright GA, Meyer CH, Macovski A, Nishimura DG (1995) Coronary angiography with magnetization-prepared T2 contrast. Magn Reson Med 33:689–696PubMedCrossRef
33.
Zurück zum Zitat Katoh M, Spuentrup E, Stuber M, Buecker A, Manning WJ, Gunther RW, Botnar RM (2005) Inversion prepared coronary MR angiography: direct visualization of coronary blood flow. Rofo 177:173–178. DOI 10.1055/s-2005-857865 PubMed Katoh M, Spuentrup E, Stuber M, Buecker A, Manning WJ, Gunther RW, Botnar RM (2005) Inversion prepared coronary MR angiography: direct visualization of coronary blood flow. Rofo 177:173–178. DOI 10.​1055/​s-2005-857865 PubMed
34.
Zurück zum Zitat Etienne A, Botnar RM, Van Muiswinkel AM, Boesiger P, Manning WJ, Stuber M (2002) “Soap-bubble” visualization and quantitative analysis of 3D coronary magnetic resonance angiograms. Magn Reson Med 48:658–666. DOI 10.1002/mrm.10253 PubMedCrossRef Etienne A, Botnar RM, Van Muiswinkel AM, Boesiger P, Manning WJ, Stuber M (2002) “Soap-bubble” visualization and quantitative analysis of 3D coronary magnetic resonance angiograms. Magn Reson Med 48:658–666. DOI 10.​1002/​mrm.​10253 PubMedCrossRef
35.
Zurück zum Zitat Scanlon PJ, Faxon DP, Audet AM, Carabello B, Dehmer GJ, Eagle KA, Legako RD, Leon DF, Murray JA, Nissen SD, Pepine CJ, Watson RM (1999) ACC/AHA guidelines for coronary angiography: a report of the American College of Cardiology/American Heart Association Task Force on Practice Guidelines (Committee on Coronary Angiography). J Am Coll Cardiol 33:1756–1824. DOI 10.1016/S0735-1097(99)00126-6 PubMedCrossRef Scanlon PJ, Faxon DP, Audet AM, Carabello B, Dehmer GJ, Eagle KA, Legako RD, Leon DF, Murray JA, Nissen SD, Pepine CJ, Watson RM (1999) ACC/AHA guidelines for coronary angiography: a report of the American College of Cardiology/American Heart Association Task Force on Practice Guidelines (Committee on Coronary Angiography). J Am Coll Cardiol 33:1756–1824. DOI 10.​1016/​S0735-1097(99)00126-6 PubMedCrossRef
36.
Zurück zum Zitat Man LC, Pauly JM, Macovski A (1997) Improved automatic off-resonance correction without a field map in spiral imaging. Magn Reson Med 37:906–913PubMedCrossRef Man LC, Pauly JM, Macovski A (1997) Improved automatic off-resonance correction without a field map in spiral imaging. Magn Reson Med 37:906–913PubMedCrossRef
37.
Zurück zum Zitat Schär M, Boesiger P, Kozerke S (2005) Considerations on startup sequences in interrupted balanced SSFP imaging at 3 Tesla. Proc ISMRM, Miami, p 249 Schär M, Boesiger P, Kozerke S (2005) Considerations on startup sequences in interrupted balanced SSFP imaging at 3 Tesla. Proc ISMRM, Miami, p 249
38.
Zurück zum Zitat Stehning C, Börnert P, Nehrke K, Dössel O (2005) Free breathing 3D balanced FFE coronary magnetic resonance angiography with prolonged cardiac acquisition windows and intra-RR motion correction. Magn Reson Med 53:719–723. DOI 10.1002/mrm.20397 PubMedCrossRef Stehning C, Börnert P, Nehrke K, Dössel O (2005) Free breathing 3D balanced FFE coronary magnetic resonance angiography with prolonged cardiac acquisition windows and intra-RR motion correction. Magn Reson Med 53:719–723. DOI 10.​1002/​mrm.​20397 PubMedCrossRef
40.
Zurück zum Zitat Hackenbroch M, Nehrke K, Gieseke J, Meyer C, Tiemann K, Litt H, Dewald O, Naehle CP, Schild H, Sommer T (2005) 3D motion adapted gating (3D MAG): a new navigator technique for accelerated acquisition of free breathing navigator gated 3D coronary MR-angiography. Eur Radiol 15:1598–1606. DOI 10.1007/s00330-005-2731-z PubMedCrossRef Hackenbroch M, Nehrke K, Gieseke J, Meyer C, Tiemann K, Litt H, Dewald O, Naehle CP, Schild H, Sommer T (2005) 3D motion adapted gating (3D MAG): a new navigator technique for accelerated acquisition of free breathing navigator gated 3D coronary MR-angiography. Eur Radiol 15:1598–1606. DOI 10.​1007/​s00330-005-2731-z PubMedCrossRef
Metadaten
Titel
Coronary vessel-wall and lumen imaging using radial k-space acquisition with MRI at 3 Tesla
verfasst von
Andrew N. Priest
P. Martin Bansmann
Kai Müllerleile
Gerhard Adam
Publikationsdatum
01.02.2007
Verlag
Springer-Verlag
Erschienen in
European Radiology / Ausgabe 2/2007
Print ISSN: 0938-7994
Elektronische ISSN: 1432-1084
DOI
https://doi.org/10.1007/s00330-006-0368-1

Weitere Artikel der Ausgabe 2/2007

European Radiology 2/2007 Zur Ausgabe

„Übersichtlicher Wegweiser“: Lauterbachs umstrittener Klinik-Atlas ist online

17.05.2024 Klinik aktuell Nachrichten

Sie sei „ethisch geboten“, meint Gesundheitsminister Karl Lauterbach: mehr Transparenz über die Qualität von Klinikbehandlungen. Um sie abzubilden, lässt er gegen den Widerstand vieler Länder einen virtuellen Klinik-Atlas freischalten.

Klinikreform soll zehntausende Menschenleben retten

15.05.2024 Klinik aktuell Nachrichten

Gesundheitsminister Lauterbach hat die vom Bundeskabinett beschlossene Klinikreform verteidigt. Kritik an den Plänen kommt vom Marburger Bund. Und in den Ländern wird über den Gang zum Vermittlungsausschuss spekuliert.

Darf man die Behandlung eines Neonazis ablehnen?

08.05.2024 Gesellschaft Nachrichten

In einer Leseranfrage in der Zeitschrift Journal of the American Academy of Dermatology möchte ein anonymer Dermatologe bzw. eine anonyme Dermatologin wissen, ob er oder sie einen Patienten behandeln muss, der eine rassistische Tätowierung trägt.

Ein Drittel der jungen Ärztinnen und Ärzte erwägt abzuwandern

07.05.2024 Klinik aktuell Nachrichten

Extreme Arbeitsverdichtung und kaum Supervision: Dr. Andrea Martini, Sprecherin des Bündnisses Junge Ärztinnen und Ärzte (BJÄ) über den Frust des ärztlichen Nachwuchses und die Vorteile des Rucksack-Modells.

Update Radiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.