Objective

Palatal rugae are frequently used in the evaluation of tooth movement after treatment in orthodontics and as a stable region in superimposition. It is important to note that the impression method and material used to record the rugae region affect the accuracy of the impression. The aim of this study is to compare the accuracy of palatal rugae, in three-dimensional (3D) by employing both conventional and digital impression methods.

Materials and methods

In this study, 22 patients (12 females, 10 males) mean age of 13.5 ± 1.7 years old were selected with complete permanent dentition. Three different impressions were taken from the maxillae of the patients: conventional impression using silicone rubber impression material, conventional impression using alginate impression material, and optical impression using an intraoral scanner. The impressions’ digital data were analyzed by the GOM Inspect (Version 2018, Braunschweig, Germany), a 3D analysis software. The Root Mean Square (RMS) values of the total ruga region were evaluated in this software. The data were statistically analyzed using the Jamovi program. The Kruskal–Wallis test and Mann–Whitney U test were performed due to the non-normal distribution of the data.

Results

There is no statistically significant difference between the comparison points of the right and left rugae’s medial and lateral points and total rugae regions’ RMS values. Although there was no statistically significant difference, the total RMS values of alginate and digital scan measurements showed closer results than the RMS values of silicone and digital scan measurements.

Conclusion

The study found that there was no statistically significant difference in the total RMS values of the ruga region between traditional and digital impression methods.

Clinical relevance

The treatment period in orthodontics is long. Different impression materials and methods can be used for diagnostic, mid-treatment, and final impressions. For superimpositions and treatment and post-treatment palatal ruga evaluations, traditional and digital impression methods are clinically acceptable and can be used as alternatives to each other.
Literatur
4.
Zurück zum Zitat Thomas CJ, Van Wyk CW (1988) The palatal rugae in an identification. J Forensic Odontostomatol 6(1):21–27PubMed Thomas CJ, Van Wyk CW (1988) The palatal rugae in an identification. J Forensic Odontostomatol 6(1):21–27PubMed
7.
Zurück zum Zitat Abdel Aziz HM, Sabet NE (2001) Palatal rugae area: a landmark for analysis of pre-and post-orthodontically treated adult Egyptian patients. EMHJ-East Mediterr Health J 7(1–2):60–66CrossRef Abdel Aziz HM, Sabet NE (2001) Palatal rugae area: a landmark for analysis of pre-and post-orthodontically treated adult Egyptian patients. EMHJ-East Mediterr Health J 7(1–2):60–66CrossRef
18.
Zurück zum Zitat Fatema S, Quader SMS, Shamsuzzaman M et al (2013) A comparative study on accuracy and reproducibility of alginate and addition reaction silicone as an ımpression materials. Update Dent Coll J 3(2):28–33CrossRef Fatema S, Quader SMS, Shamsuzzaman M et al (2013) A comparative study on accuracy and reproducibility of alginate and addition reaction silicone as an ımpression materials. Update Dent Coll J 3(2):28–33CrossRef
21.
Zurück zum Zitat International Organization for Standardization (1994) ISO 5725– 1. Accuracy (trueness and precision) of measurement methods and results - Part 1: General principles and defnitions Geneva: International Organization for Standardization. www.iso.org/obp/ui/#iso:std:iso: 5725:-1:ed-1:v1:en International Organization for Standardization (1994) ISO 5725– 1. Accuracy (trueness and precision) of measurement methods and results - Part 1: General principles and defnitions Geneva: International Organization for Standardization. www.​iso.​org/​obp/​ui/​#iso:​std:​iso: 5725:-1:ed-1:v1:en
22.
Zurück zum Zitat Faul F, Erdfelder E, Buchner A, Lang AG (2009) Statistical power analyses using G* Power 3.1: tests for correlation and regression analyses. Behav Res Methods 41(4):1149–60CrossRefPubMed Faul F, Erdfelder E, Buchner A, Lang AG (2009) Statistical power analyses using G* Power 3.1: tests for correlation and regression analyses. Behav Res Methods 41(4):1149–60CrossRefPubMed
23.
Zurück zum Zitat Emara A, Sharma N, Halbeisen FS, Msallem B, Thieringer FM (2020) Comparative evaluation of digitization of diagnostic dental cast (plaster) models using different scanning technologies. Dent J 8(3):79CrossRef Emara A, Sharma N, Halbeisen FS, Msallem B, Thieringer FM (2020) Comparative evaluation of digitization of diagnostic dental cast (plaster) models using different scanning technologies. Dent J 8(3):79CrossRef
29.
Zurück zum Zitat Ender A, Zimmermann M, Attin T, Mehl A (2016) In vivo precision of conventional and digital methods for obtaining quadrant dental impressions. Clin Oral Invest 20:1495–1504CrossRef Ender A, Zimmermann M, Attin T, Mehl A (2016) In vivo precision of conventional and digital methods for obtaining quadrant dental impressions. Clin Oral Invest 20:1495–1504CrossRef
33.
Zurück zum Zitat Seelbach P, Brueckel C, Wöstmann B (2013) Accuracy of digital and conventional impression techniques and workflow. Clin Oral Investig 17:1759–1764CrossRefPubMed Seelbach P, Brueckel C, Wöstmann B (2013) Accuracy of digital and conventional impression techniques and workflow. Clin Oral Investig 17:1759–1764CrossRefPubMed
36.
Zurück zum Zitat Muthusubramanian M, Limson KS, Julian R (2005) Analysis of rugae in burn victims and cadavers to simulate rugae identification in cases of incineration and decomposition. J Forensic Odontostomatol 23:26–29PubMed Muthusubramanian M, Limson KS, Julian R (2005) Analysis of rugae in burn victims and cadavers to simulate rugae identification in cases of incineration and decomposition. J Forensic Odontostomatol 23:26–29PubMed
38.
Zurück zum Zitat Groth C, Graham JW, Redmond WR (2014) Three-dimensional printing technology. J Clin Orthod 48(8):475–85PubMed Groth C, Graham JW, Redmond WR (2014) Three-dimensional printing technology. J Clin Orthod 48(8):475–85PubMed
Metadaten
Titel
Clinical comparative study on the accuracy of palatal rugae in models obtained by different impression materials and intraoral scanning
verfasst von
Şule Gökmen
Kübra Gülnur Topsakal
Gökhan Serhat Duran
Serkan Görgülü
Publikationsdatum
01.02.2024
Verlag
Springer Berlin Heidelberg
Erschienen in
Clinical Oral Investigations / Ausgabe 2/2024
Print ISSN: 1432-6981
Elektronische ISSN: 1436-3771
DOI
https://doi.org/10.1007/s00784-024-05556-y

Weitere Artikel der Ausgabe 2/2024

Clinical Oral Investigations 2/2024 Zur Ausgabe

„Übersichtlicher Wegweiser“: Lauterbachs umstrittener Klinik-Atlas ist online

17.05.2024 Klinik aktuell Nachrichten

Sie sei „ethisch geboten“, meint Gesundheitsminister Karl Lauterbach: mehr Transparenz über die Qualität von Klinikbehandlungen. Um sie abzubilden, lässt er gegen den Widerstand vieler Länder einen virtuellen Klinik-Atlas freischalten.

Klinikreform soll zehntausende Menschenleben retten

15.05.2024 Klinik aktuell Nachrichten

Gesundheitsminister Lauterbach hat die vom Bundeskabinett beschlossene Klinikreform verteidigt. Kritik an den Plänen kommt vom Marburger Bund. Und in den Ländern wird über den Gang zum Vermittlungsausschuss spekuliert.

Darf man die Behandlung eines Neonazis ablehnen?

08.05.2024 Gesellschaft Nachrichten

In einer Leseranfrage in der Zeitschrift Journal of the American Academy of Dermatology möchte ein anonymer Dermatologe bzw. eine anonyme Dermatologin wissen, ob er oder sie einen Patienten behandeln muss, der eine rassistische Tätowierung trägt.

Ein Drittel der jungen Ärztinnen und Ärzte erwägt abzuwandern

07.05.2024 Klinik aktuell Nachrichten

Extreme Arbeitsverdichtung und kaum Supervision: Dr. Andrea Martini, Sprecherin des Bündnisses Junge Ärztinnen und Ärzte (BJÄ) über den Frust des ärztlichen Nachwuchses und die Vorteile des Rucksack-Modells.

Update Zahnmedizin

Bestellen Sie unseren kostenlosen Newsletter und bleiben Sie gut informiert – ganz bequem per eMail.